SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Elcock C.) "

Sökning: WFRF:(Elcock C.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Shore, R. C., et al. (författare)
  • The Structure and Composition of Deciduous Enamel Affected by Local Hypoplastic Autosomal Dominant Amelogenesis Imperfecta Resulting from an ENAM Mutation
  • 2010
  • Ingår i: Cells Tissues Organs. - : S. Karger. - 1422-6405 .- 1422-6421. ; 191:4, s. 301-306
  • Tidskriftsartikel (refereegranskat)abstract
    • In a group of families in northern Sweden, a mutation in the ENAM gene (predicted to produce a highly truncated protein) results in the local hypoplastic form of autosomal dominant amelogenesis imperfecta. In this study, sections of deciduous teeth from members of 3 of these families were examined by scanning electron microscopy (SEM) and the enamel mineral was analysed by energy dispersive X-ray spectroscopy (EDX). The sections were also probed with antibodies raised to a conserved sequence of the enamelin protein. Selected intact teeth were first analysed by digital imaging and ascribed with an 'Enamel Defects Index' (EDI) score. SEM of tooth sections revealed disrupted prism morphology and the prisms had a glass-like appearance in some areas. These areas of dysplasia were sometimes irregular but formed regular arrays in others. Comparison of EDI scores with SEM indicated that in one tooth the surface had no measurable defects but significant defects were present in the underlying enamel microstructure. SEM immunohistochemistry with the antibody raised to a fragment of the enamelin protein produced positive, but light, labelling throughout normal enamel. In dysplastic areas, however, the labelling intensity appeared to be reduced. The results indicate that the presence of functional enamelin in the correct amounts is necessary for correct prism morphogenesis. In addition, a combination of EDI and structural analysis indicate that defects in enamel microstructure are not necessarily visible as defects on the surface of the tooth, suggesting the possibility, at least, that some instances of under-diagnosis may occur. Copyright (C) 2009 S. Karger AG, Basel
  •  
2.
  • Elcock, C, et al. (författare)
  • Comparison of methods for measurement of hypoplastic lesions
  • 2006
  • Ingår i: European Journal of Oral Science. ; 114:suppl 1, s. 365-369
  • Tidskriftsartikel (refereegranskat)abstract
    • Enamel hypoplasia is a quantitative defect of enamel thickness. Methods previously used for its measurement have limitations in clinical studies. The aim of this study was to investigate new methods of measurement using image analysis. Lesions on 8 teeth affected by enamel hypoplasia were quantified from study models and impression surfaces using an image-analysis system. The measurements made included lesion area and tooth surface area; from these the proportion of tooth surface area affected was calculated. For comparison, manual measurement was performed on impression surfaces and study models, using digital callipers. Images were also acquired of lesions on 12 exfoliated teeth, and the lesion area and total tooth area were calculated. For assessment of intra-operator reliability, the +/-repeatability coefficient was calculated. Measurement of the surface lesions direct from the exfoliated teeth gave the best results overall, followed by direct image analysis of the silicone impression.
  •  
3.
  • Elcock, C, et al. (författare)
  • The new enamel defects index: Testing and expansion
  • 2006
  • Ingår i: European Journal of Oral Science. ; 114:suppl 1, s. 35-38
  • Tidskriftsartikel (refereegranskat)abstract
    • The Enamel Defects Index (EDI) was created based on three innovative principles: (i) a basic level of the three major categories of defects; (ii) more detailed subcategories of each major category: and (iii) each category scored independently as present ﴾1﴿or absent ﴾0﴿, simplifying decision making. The aim of this investigation was to further test the index in a number of applications and to expand it to record defect subtype and treatment need. Testing was undertaken by operators with different levels of clinical experience. A computer-assisted learning (CAL) package was developed for operator training and calibration. The index was also used on clinical photographs and high-resolution digital images of exfoliated and extracted teeth. Scoring of photographs revealed substantial intra-operator agreement. Training using the CAL package resulted in significant improvement in index use. Intra-operator reproducibility was good to excellent, and interoperator reproducibility was good for buccal surfaces on digital images. Index expansion allowed information on defect subtype, location, and treatment need to be gathered readily. The EDI has high reproducibility and allows more rapid and accurate data collection from clinical and in vitro studies than the Fédération Dentaire Internationale Developmental Defects of Enamel index.
  •  
4.
  • Smith, RN, et al. (författare)
  • Enamel defects in extracted and exfoliated teeth from patients with Amelogenesis Imperfecta, measured using the extended enamel defects index and image analysis
  • 2008
  • Ingår i: Archives of Oral Biology. - Oxford : Pergamon Press. - 0003-9969 .- 1879-1506. ; 54:Suppl 1, s. S86-S92
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: To enhance the phenotypic description and quantification of enamel defects from a North Sweden sample of extracted and exfoliated teeth originating from families with Amelogenesis Imperfecta by use of the extended enamel defects index (EDI) and image analysis to demonstrate the comparable reliability and value of the additional measurements.METHODS AND RESULTS: The sample comprised 109 deciduous and 7 permanent teeth from 32 individuals of 19 families with Amelogenesis Imperfecta in Northern Sweden. A special holder for individual teeth was designed and the whole sample was examined using the extended EDI and an image analysis system. In addition to the extended EDI definitions, the calibrated images were measured for tooth surface area, defect area and percentage of surface affected using image analysis techniques. The extended EDI was assessed using weighted and unweighted Kappa statistics. The reliability of imaging and measurement was determined using Fleiss' intra-class correlation coefficient (ICCC). Kappa values indicated good or excellent intra-operator repeatability and inter-operator reproducibility for the extended EDI. The Fleiss ICCC values indicated excellent repeatability for the image analysis measurements. Hypoplastic pits on the occlusal surfaces were the most frequent defect in this sample (82.6%). The occlusal surface displayed the most post-eruptive breakdown (39.13%) whilst the incisal portion of the buccal surfaces showed most diffuse opacities (53.4%). Image analysis methods demonstrated the largest mean hypoplastic pit areas were on the lingual surfaces. The largest mean post-eruptive breakdown areas were on the lingual surfaces of posterior teeth. The largest mean demarcated opacity areas were found on the labial surfaces.CONCLUSIONS: The extended EDI and the standardised image acquisition and analysis system provided additional information to conventional measurement techniques. Additional phenotypic variables were described.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4
Typ av publikation
tidskriftsartikel (4)
Typ av innehåll
refereegranskat (4)
Författare/redaktör
Elcock, C (4)
Smith, RN (3)
Brook, AH (3)
Simpson, J (2)
Bäckman, B (2)
Bäckman, Birgitta (2)
visa fler...
Abdellatif, A (2)
Russell, JM (1)
Kirkham, J (1)
Brookes, S.J. (1)
Shore, R. C. (1)
Brook, A. H. (1)
visa färre...
Lärosäte
Umeå universitet (4)
Språk
Engelska (4)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy