SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Engberg Anna E. 1982 ) "

Sökning: WFRF:(Engberg Anna E. 1982 )

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bexborn, Fredrik, et al. (författare)
  • Hirudin versus heparin for use in whole blood in vitro biocompatibility models
  • 2009
  • Ingår i: Journal of Biomedical Materials Research. Part A. - Hoboken, NJ, US : John Wiley & Sons Inc. - 1549-3296 .- 1552-4965. ; 89A:4, s. 951-959
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Heparin has traditionally been a widely used anticoagulant in blood research, but has been shown to be inappropriate for work with the complement system because of its complement-interacting properties. In this work, we have compared the effects of heparin with those of the specific thrombin inhibitor hirudin on complement and blood cells in vitro. Methods: Whole blood collected in the presence of hirudin (50 µg/mL) or heparin (1 IU/mL) was incubated in the slide chamber model. The plasma was analyzed for complement activation markers C3a and sC5b-9, and the polyvinylchloride test slides were stained for adhering cells. The integrity of the complement system was tested by incubating serum and hirudin-treated plasma in the presence of various activating agents.Results: In contrast to heparin, the addition of hirudin generally preserved the complement reactivity, and complement activation in hirudin plasma closely resembled that in normal serum. Importantly, immunochemical staining of surface-bound cells demonstrated the inducible expression of tissue factor on bound monocytes from hirudin-treated blood, an effect that was completely abolished in heparin-treated blood.Conclusion: Our results indicate that hirudin as an anticoagulant produces more physiological conditions than heparin, making hirudin well-suited for in vitro studies, especially those addressing the regulation of cellular processes.
  •  
2.
  • Engberg, Anna E., 1982- (författare)
  • Biomaterials and Hemocompatibility
  • 2010
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Biomaterials are commonly used in the medical clinic today; however, artificial materials can activate the cascade systems in the blood (complement-, coagulation-, contact- and fibrinolytic systems) as well as the platelets to various degrees. When an artificial surface comes in contact with blood, plasma proteins will be adsorbed to the surface within seconds. The composition of the layer of proteins differs between materials and is crucial for the hemocompatibility of the material.This thesis includes five projects.In Paper I the anticoagulants heparin and the thrombin inhibitor hirudin were evaluated in a whole blood model. Hirudin was found to be superior to low dose heparin since it did not affect the activation of the complement system nor the leukocytes. The most interesting observation was that expression of TF was seen on surface-attached monocytes in hirudin- treated blood but not heparin blood.In Paper II peptides from the streptococcal M-protein, which has affinity for the human complement inhibitor C4BP, were attached to a polymeric surface. When being exposed to blood the endogenous complement regulator was enriched at the surface of the material, via the M-peptides. With this new approach we created a self-regulatory surface, showing significant lowered material-induced complement activation.In Paper III apyrase, an enzyme which hydrolyzes nucleoside ATP and ADP, was immobilized on a polymer surface. Lower platelet activation and platelet-induced coagulation activation was seen for the apyrase-coated surface compared to control surfaces after exposure to whole human blood, due to the enzymes capability to degrade ADP released from activated platelets.In Paper IV and V we synthesized an array of polymeric materials which were characterized regarding physical-chemical properties, adsorption of plasma proteins, and hemocompatibility. The polymers showed widely heterogeneous protein adsorption. Furthermore, when the polymers were exposed to whole blood, two of the materials showed superior hemocompatibility (monitored as complement- and coagulation activation), compared to the reference poly(vinyl chloride).
  •  
3.
  • Engberg, Anna E., 1982-, et al. (författare)
  • EVALUATION OF THE HEMOCOMPATIBILITY OF NOVEL POLYMERIC MATERIALS
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • When a biomaterial surface comes in contact with blood an immediate adsorption of plasma proteins to the surface will occur, and the cascade systems in the blood, such as the complement, coagulation and contact system, will be activated to various degrees. The intensity of this reaction will determine the hemocompatibility of the materials. Here we present an evaluation of the link between the composition, the physico-chemical properties and the protein adsorption properties of six newly synthesized polymers (P1-P6) and the hemocompatibility.The hemocompatibility of the polymeric surfaces was evaluated in human blood plasma and whole blood. Commercially available polyvinylchloride (PVC) was used as reference material. The hemocompatibility of the polymeric surfaces was evaluated with regard to complement activation (C3a and sC5-9 generation) and coagulation activation (platelet loss and TAT-formation) and cytokine productions (27 analytes in multiplex assay) after contact with whole blood. Contact activation was quantified by analyses of FXIIa-C1INH, FXIa-C1INH, and kallikrein-C1INH complexes.Polymers P2 (p<0.05 for C3a), P3, P5 and P6 showed less complement activation, and polymers P1 and P4 (p<0.05 for platelet loss), as well as P5 and P6 showed less coagulation activation compared with reference PVC. Polymers P1-P3 induced activation of the contact system, P3 being the most potent. Secretion of 17 cytokines including chemokines and growth factors were differentially influenced by the polymers, P1 and P3 being significantly (p<0.05) more compatible for five of the analytes.Collectively these data demonstrate that the composition of the polymers clearly leads to different biological properties as a consequence of distinctive physico-chemical properties and protein adsorption patterns.1
  •  
4.
  • Engberg, Anna E., 1982-, et al. (författare)
  • Inhibition of complement activation on a model biomaterial surface by streptococcal M protein-derived peptides
  • 2009
  • Ingår i: Biomaterials. - : Elsevier. - 0142-9612 .- 1878-5905. ; 30:13, s. 2653-2659
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to evaluate a new approach to inhibit complement activation triggered by biomaterial surfaces in contact with blood. In order to inhibit complement activation initiated by the classical pathway (CP), we used streptococcal M protein-derived peptides that specifically bind human C4BP, an inhibitor of the CP. The peptides were used to coat polystyrene microtiter wells which served as a model biomaterial. The ability of coated peptides to bind C4BP and to attenuate complement activation via the CP (monitored as generation of fluid-phase C3a and binding of fragments of C3 and C4 to the surface) was investigated using diluted normal human serum, where complement activation by the AP is minimal, as well as serum from a patient lacking alternative pathway activation. Complement activation (all parameters) was significantly decreased in serum incubated in well surfaces coated with peptides. Total inhibition of complement activation was obtained at peptide coating concentrations as low as 1-5 mu g/mL. Successful use of Streptococcus-derived peptides shows that it is feasible to control complement activation at a model biomaterial surface by capturing autologous complement regulatory molecules from plasma. (C) 2009 Elsevier Ltd. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy