SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Escobar Kvitting John Peder) "

Sökning: WFRF:(Escobar Kvitting John Peder)

  • Resultat 1-10 av 64
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bolger, Ann F, 1957-, et al. (författare)
  • Transit of blood flow through thehuman left ventricle mapped by cardiovascular magnetic resonance
  • 2007
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Informa UK Limited. - 1097-6647 .- 1532-429X. ; 9:5, s. 741-747
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:The transit of blood through the beating heart is a basic aspect of cardiovascular physiology which remains incompletely studied. Quantification of the components of multidirectional flow in the normal left ventricle (LV) is lacking, making it difficult to put the changes observed with LV dysfunction and cardiac surgery into context.METHODS:Three dimensional, three directional, time resolved magnetic resonance phase-contrast velocity mapping was performed at 1.5 Tesla in 17 normal subjects, 6 female, aged 44+/-14 years (mean+/-SD). We visualized and measured the relative volumes of LV flow components and the diastolic changes in inflowing kinetic energy (KE). Of total diastolic inflow volume, 44+/-11% followed a direct, albeit curved route to systolic ejection (videos 1 and 2), in contrast to 11% in a subject with mildly dilated cardiomyopathy (DCM), who was included for preliminary comparison (video 3). In normals, 16+/-8% of the KE of inflow was conserved to the end of diastole, compared with 5% in the DCM patient. Blood following the direct route lost or transferred less of its KE during diastole than blood that was retained until the next beat (1.6+/-1.0 millijoules vs 8.2+/-1.9 millijoules, p<0.05); whereas, in the DCM patient, the reduction in KE of retained inflow was 18-fold greater than that of the blood tracing the direct route.CONCLUSION:Multidimensional flow mapping can measure the paths, compartmentalization and kinetic energy changes of blood flowing into the LV, demonstrating differences of KE loss between compartments, and potentially between the flows in normal and dilated left ventricles.
  •  
2.
  • Bothe, Wolfgang, et al. (författare)
  • Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia
  • 2011
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier. - 0022-5223 .- 1097-685X. ; 141:2, s. 345-353
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The study objective was to quantify the effects of different annuloplasty rings on mitral leaflet septal-lateral tenting areas during acute myocardial ischemia. Methods Radiopaque markers were implanted along the central septal-lateral meridian of the mitral valve in 30 sheep: 1 each to the septal and lateral aspects of the mitral annulus and 4 and 2 along the anterior and posterior mitral leaflets, respectively. Ten true-sized Carpentier-Edwards Physio, Edwards IMR ETLogix, and GeoForm annuloplasty rings (Edwards Lifesciences, Irvine, Calif) were inserted in a releasable fashion. Marker coordinates were obtained using biplane videofluoroscopy with ring inserted at baseline (RING_BL) and after 90 seconds of left circumflex artery occlusion (RING_ISCH). After ring release, another dataset was acquired before (No_Ring_BL) and after left circumflex artery occlusion (No_Ring_ISCH). Anterior and posterior mitral leaflet tenting areas were computed at mid-systole from sums of marker triangles with the midpoint between the annular markers being the vertex for all triangles. Results Compared with No_Ring_BL, mitral regurgitation grades and all tenting areas significantly increased with No_Ring_ISCH. Compared with No_Ring_ISCH, (1) all rings significantly prevented mitral regurgitation and reduced all tenting areas; (2) Edwards IMR ETLogix and GeoForm rings reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, to a significantly greater extent than the Carpentier-Edwards Physio ring; and (3) Edwards IMR ETLogix and GeoForm rings affected tenting areas similarly. Conclusions In response to acute left ventricular ischemia, disease-specific functional/ischemic mitral regurgitation rings (Edwards IMR ETLogix, GeoForm) more effectively reduced posterior mitral leaflet area, but not anterior mitral leaflet tenting area, compared with true-sized physiologic rings (Carpentier-Edwards Physio). Despite its radical 3-dimensional shape and greater amount of mitral annular septal-lateral downsizing, the GeoForm ring did not reduce tenting areas more than the Edwards IMR ETLogix ring, suggesting that further reduction in tenting areas in patients with FMR/IMR may not be effectively achieved on an annular level.
  •  
3.
  • Bothe, Wolfgang, et al. (författare)
  • Rigid, complete annuloplasty rings increase anterior mitral leaflet strain in normal beating ovine heart
  • 2011
  • Ingår i: Circulation. - 0009-7322 .- 1524-4539. ; 124, s. S81-S96
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Annuloplasty ring or band implantation during surgical mitral valve repair perturbs mitral annular dimensions, dynamics, and shape, which have been associated with changes in anterior mitral leaflet (AML) strain patterns and suboptimal long-term repair durability. We hypothesized that rigid rings with nonphysiological three-dimensional shapes, but not saddle-shaped rigid rings or flexible bands, increase AML strains. METHODS AND RESULTS: Sheep had 23 radiopaque markers inserted: 7 along the anterior mitral annulus and 16 equally spaced on the AML. True-sized Cosgrove-Edwards flexible, partial band (n=12), rigid, complete St Jude Medical rigid saddle-shaped (n=12), Carpentier-Edwards Physio (n=12), Edwards IMR ETlogix (n=11), and Edwards GeoForm (n=12) annuloplasty rings were implanted in a releasable fashion. Under acute open-chest conditions, 4-dimensional marker coordinates were obtained using biplane videofluoroscopy along with hemodynamic parameters with the ring inserted and after release. Marker coordinates were triangulated, and the largest maximum principal AML strains were determined during isovolumetric relaxation. No relevant changes in hemodynamics occurred. Compared with the respective control state, strains increased significantly with rigid saddle-shaped annuloplasty ring, Carpentier-Edwards Physio, Edwards IMR ETlogix, and Edwards GeoForm (0.14 ± 0.05 versus 0.16 ± 0.05, P=0.024, 0.15 ± 0.03 versus 0.18 ± 0.04, P=0.020, 0.11 ± 0.05 versus 0.14 ± 0.05, P=0.042, and 0.13 ± 0.05 versus 0.16 ± 0.05, P=0.009), but not with Cosgrove-Edwards band (0.15 ± 0.05 versus 0.15 ± 0.04, P=0.973). CONCLUSIONS: Regardless of three-dimensional shape, rigid, complete annuloplasty rings, but not a flexible, partial band, increased AML strains in the normal beating ovine heart. Clinical studies are needed to determine whether annuloplasty rings affect AML strains in patients, and, if so, whether ring-induced perturbations in leaflet strain states are linked to repair failure.
  •  
4.
  • Dyverfeldt, Petter, 1980-, et al. (författare)
  • Assessment of fluctuating velocities in disturbed cardiovascular blood flow : in vivo feasibility of generalized phase-contrast MRI
  • 2008
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 28:3, s. 655-663
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo evaluate the feasibility of generalized phase-contrast magnetic resonance imaging (PC-MRI) for the noninvasive assessment of fluctuating velocities in cardiovascular blood flow.Materials and MethodsMultidimensional PC-MRI was used in a generalized manner to map mean flow velocities and intravoxel velocity standard deviation (IVSD) values in one healthy aorta and in three patients with different cardiovascular diseases. The acquired data were used to assess the kinetic energy of both the mean (MKE) and the fluctuating (TKE) velocity field.ResultsIn all of the subjects, both mean and fluctuating flow data were successfully acquired. The highest TKE values in the patients were found at sites characterized by abnormal flow conditions. No regional increase in TKE was found in the normal aorta.ConclusionPC-MRI IVSD mapping is able to detect flow abnormalities in a variety of human cardiovascular conditions and shows promise for the quantitative assessment of turbulence. This approach may assist in clarifying the role of disturbed hemodynamics in cardiovascular diseases.
  •  
5.
  •  
6.
  • Dyverfeldt, Petter, et al. (författare)
  • Extending 4D Flow Visualization to the Human Right Ventricle
  • 2009
  • Ingår i: Proceedings of International Society for Magnetic Resonance in Medicine: 17th Scientific Meeting 2009. - : International Society for Magnetic Resonance in Medicine. ; , s. 3860-3860
  • Konferensbidrag (refereegranskat)abstract
    • The right ventricle has an important role in cardiovascular disease. However, because of the complex geometry and the sensitivity to the respiratory cycle, imaging of the right ventricle is challenging. We investigated whether 3D cine phase-contrast MRI can provide data with sufficient accuracy for visualizations of the 4D blood flow in the right ventricle. Whole-heart 4D flow measurements with optimized imaging parameters and post-processing tools were made in healthy volunteers. Pathlines emitted from the right atrium could be traced through the right ventricle to the pulmonary artery without leaving the blood pool and thereby met our criteria for sufficient accuracy.
  •  
7.
  • Dyverfeldt, Petter, et al. (författare)
  • Hemodynamic aspects of mitral regurgitation assessed by generalized phase-contrast MRI
  • 2011
  • Ingår i: Journal of Magnetic Resonance Imaging. - : John Wiley and Sons. - 1053-1807 .- 1522-2586. ; 33:3, s. 582-588
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Mitral regurgitation creates a high velocity jet into the left atrium (LA), contributing both volume andpressure; we hypothesized that the severity of regurgitation would be reflected in the degree of LA flowdistortion.Material and Methods: Three-dimensional cine PC-MRI was applied to determine LA flow patterns andturbulent kinetic energy (TKE) in seven subjects (five patients with posterior mitral leaflet prolapse, two normalsubjects). In addition, the regurgitant volume and the time-velocity profiles in the pulmonary veins weremeasured.Results: The LA flow in the mitral regurgitation patients was highly disturbed with elevated values of TKE.Peak TKE occurred consistently at late systole. The total LA TKE was closely related to the regurgitant volume.LA flow patterns were characterized by a pronounced vortex in proximity to the regurgitant jet. In some patients,pronounced discordances were observed between individual pulmonary venous inflows, but these could not berelated to the direction of the flow jet or parameters describing global LA hemodynamics.Conclusion: PC-MRI permits investigations of atrial and pulmonary vein flow patterns and TKE in significantmitral regurgitation, reflecting the impact of the highly disturbed blood flow that accompanies this importantvalve disease.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 64
Typ av publikation
tidskriftsartikel (39)
konferensbidrag (19)
doktorsavhandling (3)
annan publikation (2)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (49)
övrigt vetenskapligt/konstnärligt (15)
Författare/redaktör
Sigfridsson, Andreas (17)
Engvall, Jan, 1953- (13)
Ebbers, Tino (13)
Dyverfeldt, Petter (12)
Wigström, Lars (9)
Bolger, Ann F, 1957- (8)
visa fler...
Bolger, Ann F (7)
Knutsson, Hans (6)
Engvall, Jan (5)
Carlhäll, Carljohan (4)
Ramström, Sofia, 197 ... (4)
Wranne, Bengt, 1940- (4)
Cederholm, Ingemar (3)
Hermansson, Ulf (3)
Franzén, Stefan (3)
Szabó, Zoltan (3)
Andersson, Mats (2)
Alfredsson, Joakim, ... (2)
Berg, Sören (2)
Sutherland, George R (2)
Ha, Hojin (2)
Svensson, Anders (1)
Andersson, Peter (1)
Boano, Gabriella (1)
Baranowski, Jacek (1)
Nielsen, Niels Erik (1)
Koul, Bansi (1)
Alfredsson, Joakim (1)
Dhooge, Jan (1)
Schött, Ulf, Associa ... (1)
Walther, Sten, 1954- (1)
Aukrust, Pal (1)
Lundberg, Magnus (1)
Mollnes, Tom Eirik (1)
Nilsson, Per H., 198 ... (1)
Karlsson, Matts (1)
Kullman, Eric, 1952- (1)
Borch, Kurt, 1944- (1)
Eriksson, Jonatan (1)
Hatle, Liv (1)
Karlsson, Matts, 196 ... (1)
Wranne, Bengt (1)
Broqvist, Mats, 1955 ... (1)
Berg, Sören, 1954- (1)
Carlhäll, Carl-Johan (1)
Walther, Sten, Assoc ... (1)
Rosén, Magnus (1)
Nielsen, Niels Erik, ... (1)
Björkman, Erik (1)
Heiberg, Einar, 1973 ... (1)
visa färre...
Lärosäte
Linköpings universitet (62)
Örebro universitet (3)
Lunds universitet (2)
Linnéuniversitetet (1)
Språk
Engelska (62)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (27)
Teknik (6)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy