SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fakhro Mohammed) "

Sökning: WFRF:(Fakhro Mohammed)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andreasson, Jesper, et al. (författare)
  • Exhaled phospholipid transfer protein and hepatocyte growth factor receptor in lung adenocarcinoma
  • 2022
  • Ingår i: Respiratory Research. - : Springer Science and Business Media LLC. - 1465-9921 .- 1465-993X. ; 23:1, s. 1-10
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Screening decreases mortality among lung cancer patients but is not widely implemented, thus there is an unmet need for an easily accessible non-invasive method to enable early diagnosis. Particles in exhaled air offer a promising such diagnostic tool. We investigated the validity of a particles in exhaled air device (PExA) to measure the particle flow rate (PFR) and collect exhaled breath particles (EBP) to diagnose primary lung adenocarcinoma (LUAD).METHODS: Seventeen patients listed for resection of LUAD stages IA-IIIA and 18 non-cancer surgical control patients were enrolled. EBP were collected before and after surgery for LUAD, and once for controls. Proteomic analysis was carried out using a proximity extension assay technology. Results were validated in both plasma from the same cohort and with microarray data from healthy lung tissue and LUAD tissue in the GSE10072 dataset.RESULTS: Of the 92 proteins analyzed, levels of five proteins in EBP were significantly higher in the LUAD patients compared to controls. Levels of phospholipid transfer protein (PLTP) and hepatocyte growth factor receptor (MET) decreased in LUAD patients after surgery compared to control patients. PFR was significantly higher in the LUAD cohort at all timepoints compared to the control group. MET in plasma correlated significantly with MET in EBP.CONCLUSION: Collection of EBP and measuring of PFR has never been performed in patients with LUAD. In the present study PFR alone could distinguish between LUAD and patients without LUAD. PLTP and MET were identified as potential biomarkers to evaluate successful tumor excision.
  •  
2.
  • Broberg, Ellen, et al. (författare)
  • Mechanically ventilated patients exhibit decreased particle flow in exhaled breath as compared to normal breathing patients
  • 2020
  • Ingår i: Erj Open Research. - : European Respiratory Society (ERS). - 2312-0541. ; 6:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: In this cohort study, we evaluated whether the particles in exhaled air (PExA) device can be used in conjunction with mechanical ventilation during surgery. The PExA device consists of an optical particle counter and an impactor that collects particles in exhaled air. Our aim was to establish the feasibility of the PExA device in combination with mechanical ventilation (MV) during surgery and if collected particles could be analysed. Patients with and without nonsmall cell lung cancer (NSCLC) undergoing lung surgery were compared to normal breathing (NB) patients with NSCLC. Methods: A total of 32 patients were included, 17 patients with NSCLC (MV-NSCLC), nine patients without NSCLC (MV-C) and six patients with NSCLC and not intubated (NB). The PEx samples were analysed for the most common phospholipids in surfactant using liquid-chromatography-mass-spectrometry (LCMS). Results: MV-NSCLC and MV-C had significantly lower numbers of particles exhaled per minute ( particle flow rate; PFR) compared to NB. MV-NSCLC and MV-C also had a siginificantly lower amount of phospholipids in PEx when compared to NB. MV-NSCLC had a significantly lower amount of surfactant A compared to NB. Conclusion: We have established the feasibility of the PExA device. Particles could be collected and analysed. We observed lower PFR from MV compared to NB. High PFR during MV may be due to more frequent opening and closing of the airways, known to be harmful to the lung. Online use of the PExA device might be used to monitor and personalise settings for mechanical ventilation to lower the risk of lung damage.
  •  
3.
  • Broberg, Ellen, et al. (författare)
  • Releasing high positive end-expiratory pressure to a low level generates a pronounced increase in particle flow from the airways
  • 2023
  • Ingår i: Intensive Care Medicine Experimental. - : Springer Science and Business Media LLC. - 2197-425X. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Detecting particle flow from the airways by a non-invasive analyzing technique might serve as an additional tool to monitor mechanical ventilation. In the present study, we used a customized particles in exhaled air (PExA) technique, which is an optical particle counter for the monitoring of particle flow in exhaled air. We studied particle flow while increasing and releasing positive end-expiratory pressure (PEEP). The aim of this study was to investigate the impact of different levels of PEEP on particle flow in exhaled air in an experimental setting. We hypothesized that gradually increasing PEEP will reduce the particle flow from the airways and releasing PEEP from a high level to a low level will result in increased particle flow. Methods: Five fully anesthetized domestic pigs received a gradual increase of PEEP from 5 cmH2O to a maximum of 25 cmH2O during volume-controlled ventilation. The particle count along with vital parameters and ventilator settings were collected continuously and measurements were taken after every increase in PEEP. The particle sizes measured were between 0.41 µm and 4.55 µm. Results: A significant increase in particle count was seen going from all levels of PEEP to release of PEEP. At a PEEP level of 15 cmH2O, there was a median particle count of 282 (154–710) compared to release of PEEP to a level of 5 cmH2O which led to a median particle count of 3754 (2437–10,606) (p < 0.009). A decrease in blood pressure was seen from baseline to all levels of PEEP and significantly so at a PEEP level of 20 cmH2O. Conclusions: In the present study, a significant increase in particle count was seen on releasing PEEP back to baseline compared to all levels of PEEP, while no changes were seen when gradually increasing PEEP. These findings further explore the significance of changes in particle flow and their part in pathophysiological processes within the lung.
  •  
4.
  • Fakhro, Mohammed, et al. (författare)
  • 25-year follow-up after lung transplantation at Lund University Hospital in Sweden : superior results obtained for patients with cystic fibrosis
  • 2016
  • Ingår i: Interactive Cardiovascular and Thoracic Surgery. - : Oxford University Press (OUP). - 1569-9285 .- 1569-9293. ; 23:1, s. 65-73
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: In Sweden, two centres perform lung transplantation for a population of about 9 million and the entire population is covered for lung transplantation by government health insurance. Lund University Hospital is one of these centres. This retrospective report reviews the 25-year experience of the Skåne University Hospital Lung Transplant Program with particular emphasis on short-term outcome and long-term survival but also between different subgroups of patients and types of transplant [single-lung transplantation (SLTx) versus double-lung transplantation (DLTx)] procedure performed.METHODS: Between January 1990 and June 2014, 278 patients underwent lung transplantation at the Skåne University Hospital Sweden. DLTx was performed in 172 patients, SLTx was performed in 97 patients and heart-lung transplantation was performed in 9 patients. In addition, 15 patients required retransplantation (7 DLTx and 8 SLTx).RESULTS: Overall 1-, 5-, 10-, 15- and 20-year survival rates were 88, 65, 49, 37 and 19% for the whole cohort. DLTx recipients showed 1-, 5-, 10- and 20-year survival rates of 90, 71, 60 and 30%, compared with SLTx recipients with 1-, 5-, 10- and 20-year survival rates of 83, 57, 34 and 6% (P < 0.05), respectively. Comparing the use of intraoperative extracorporeal membrane oxygenation, extracorporeal circulation (ECC) and no circulatory support in the aspect of survival, a significant difference in favour of intraoperative ECC was seen.CONCLUSIONS: Superior long-term survival rates were seen in recipients diagnosed with cystic fibrosis, α1-antitrypsin deficiency and pulmonary hypertension. DLTx showed better results compared with SLTx especially at 10 years post-transplant. In the present study, we present cumulative incidence rates of bronchiolitis obliterans syndrome of 15% at 5 years, 26% at 10 years and 32% at 20 years post-transplant; these figures are in line with the lowest rates presented internationally.
  •  
5.
  • Fakhro, Mohammed, et al. (författare)
  • ABO-identical matching has no superiority in long-term survival in comparison to ABO-compatible matching in lung transplantation
  • 2019
  • Ingår i: Journal of Cardiothoracic Surgery. - : Springer Science and Business Media LLC. - 1749-8090. ; 14:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Even though identical blood group matching between recipient and donor is preferred, it is still not clear by how much this improves the outcome for patients who received a lung transplant (LTx), or whether there is any survival benefit. Earlier studies have yielded ambiguous results and few have investigated long-term survival. The aim of this study is, therefore, to explore the different outcomes of identical and compatible recipient and donor blood group matching to determine whether identical matching is superior (LTx). Method: Between January 1990 to June 2016, 297 patients underwent primary LTx, 10 patients underwent heart and lung transplantation (HLTx), and 18 patients required re-transplantation (Re-LTx) at Skåne University Hospital in Lund. With a total of 325 transplantations at our center, 262 were ABO-identically matched while 53 were ABO-compatible. For survival analyses, the end-point used was retransplantation-free survival in addition to excluding HLTx (n = 10), assessed by Cox regression and Kaplan-Meier. Results: ABO-compatible patients had a median of 49 days (2-641), and ABO-identical patients had a median of 89 days (1-1717) (p = 0.048) on the transplant waiting list. Patients with a limited survival up to 1-year showed significant difference in survival rate for ABO-compatible recipients compared to ABO-identical recipients (p < 0.05), however no significant difference was shown in overall survival between the two groups (p > 0.05), with the same pattern shown in patients with a limited survival rate up to ten years, emphysema-patients, when excluding single-LTx and patients transplanted before 2005 and after 2005, respectively (p > 0.05). Conclusion: Recipients who received ABO-compatible matched grafts showed a similar survival rate to recipients who received ABO-identical matched grafts in the present study. Cytolomegalovirus and Ebstein Barr Virus mismatch were also identified as risk factors particular among emphysema patients. Since ABO-identical transplantations and ABO-compatible transplantations showed similar results, the present selection-bias of preferring ABO-identical lungs could be adjusted to increase organ allocation. It might also be possible to shorten recipient waiting list time, as an identical match showed over 80% higher time on the waiting list than a compatible, non-identical match.
  •  
6.
  •  
7.
  • Fakhro, Mohammed, et al. (författare)
  • Double lung, unlike single lung transplantation might provide a protective effect on mortality and bronchiolitis obliterans syndrome
  • 2017
  • Ingår i: Journal of Cardiothoracic Surgery. - : Springer Science and Business Media LLC. - 1749-8090. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Survival after lung transplantation (LTx) is often limited by bronchiolitis obliterans syndrome (BOS).METHOD: Survey of 278 recipients who underwent LTx. The endpoint used was BOS (BOS grade ≥ 2), death or Re-lung transplantation (Re-LTx) assessed by competing risk regression analyses.RESULTS: The incidence of BOS grade ≥ 2 among double LTx (DLTx) recipients was 16 ± 3% at 5 years, 30 ± 4% at 10 years, and 37 ± 5% at 20 years, compared to single LTx (SLTx) recipients whose corresponding incidence of BOS grade ≥ 2 was 11 ± 3%, 20 ± 4%, and 24 ± 5% at 5, 10, and 20 years, respectively (p > 0. 05). The incidence of BOS grade ≥ 2 by major indications ranked in descending order: other, PF, CF, COPD, PH and AAT1 (p < 0. 05). The mortality rate by major indication ranked in descending order: COPD, PH, AAT1, PF, Other and CF (p < 0. 05).CONCLUSION: No differences were seen in the incidence of BOS grade ≥ 2 regarding type of transplant, however, DLTx recipients showed a better chance of survival despite developing BOS compared to SLTx recipients. The highest incidence of BOS was seen among CF, PF, COPD, PH, and AAT1 recipients in descending order, however, CF and PF recipients showed a better chance of survival despite developing BOS compared to COPD, PH, and AAT1 recipients.
  •  
8.
  •  
9.
  •  
10.
  • Fakhro, Mohammed, et al. (författare)
  • Impact of Forced Expiratory Volume in 1 Second (FEV1) and 6-Minute Walking Distance at 3, 6, and 12 Months and Annually on Survival and Occurrence of Bronchiolitis Obliterans Syndrome (BOS) After Lung Transplantation
  • 2017
  • Ingår i: Annals of Transplantation. - 2329-0358. ; 22, s. 532-540
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Development of bronchiolitis obliterans syndrome (BOS) is a great limitation for patient survival in lung transplantation (LTx). A curative treatment for BOS is still missing, and in terminal stages re-transplantation (Re-LTx) is the only salvation. It is possible to slow the progress of BOS if it is detected at an early stage. This might be possible by assessing pulmonary function pattern. MATERIAL AND METHODS Between 1990 and 2014, 278 patients underwent LTx at Skåne University Hospital, Sweden. Pulmonary function was followed using spirometry (FEV1) and 6-minute walking test (6MWT) measured at 3, 6, and 12 months and annually. The endpoint used was freedom from BOS (BOS grade ≤1), BOS (BOS grade ≥2), and death or Re-LTx. RESULTS Double-lung transplantation (DLTx) showed a hazard ratio (HR) of 0.514 (p=0.001) versus recipients who underwent single-lung transplantation (SLTx). Regarding freedom from BOS, FEV1 showed an HR of 0.597 and 6MWT an HR of 0.982 (p<0.001). Regarding combined endpoint BOS ≥2 and Re-LTx, FEV1 showed an HR of 0.618 and 6MWT an HR of 0.972 (p<0.001). CONCLUSIONS Recipients with higher FEV1 or 6MWT values had better chances of survival. Recipients with DLTx had a significant survival benefit and a protective effect against development of BOS. As the distance that the patient can walk in 6 minutes increases, risk for death or Re-LTx is significantly lower, as is incidence of developing BOS grade ≥2. Understanding changes within pulmonary function are probably key to understanding patient prognosis.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy