SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fehrenbacher G.) "

Sökning: WFRF:(Fehrenbacher G.)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bilski, P., et al. (författare)
  • The problems associated with the monitoring of complex workplace radiation fields at European high-energy accelerators and thermonuclear fusion facilities
  • 2007
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 126:1-4, s. 491-496
  • Tidskriftsartikel (refereegranskat)abstract
    • The European Commission is funding within its Sixth Framework Programme a three-year project (2005-2007) called CONRAD, COordinated Network for RAdiation Dosimetry. The organisational framework for this project is provided by the European Radiation Dosimetry Group EURADOS. One task within the CONRAD project, Work Package 6 (WP6), was to provide a report outlining research needs and research activities within Europe to develop new and improved methods and techniques for the characterisation of complex radiation fields at workplaces around high-energy accelerators, but also at the next generation of thermonuclear fusion facilities. The paper provides an overview of the report, which will be available as CERN Yellow Report.
  •  
2.
  • Fehrenbacher, G., et al. (författare)
  • Measurement of the fluence response of the GSI neutron ball in high-energy neutron fields produced by 500 A Mev and 800 AMev deuterons
  • 2007
  • Ingår i: Radiation Protection Dosimetry. - 0144-8420 .- 1742-3406. ; 126:1-4, s. 497-500
  • Tidskriftsartikel (refereegranskat)abstract
    • Experiments were performed in Cave C of GSI (Gesellschaft fur Schwerionenforschung) using the LAND (Large Area Neutron Detector) in combination with the deflection magnet ALADIN (A LArge DIpol magNet) in front of the LAND where charged particles and neutrons can be separated. This arrangement is used to create high-energetic neutron fields by irradiation of a thick lead target (5 cm) with deuteron beams with the energies of 500 or 800 MeV per nucleon. In break-up reactions the neutron is separated from the proton which is deflected in the magnetic field of the ALADIN. The produced neutron radiation, which has a pronounced peak at the nucleon energy, is used to measure the fluence response of the GSI neutron ball. A thermoluminescence (TL) based spherical neutron dosemeter was developed for the area monitoring for the quantity H*(10) at high-energy accelerators. In the same experiment, the spectral neutron fluence Phi(E) is measured with the LAND in the energy range from 100 MeV to 1 GeV. The measured fluence responses are compared with results of FLUKA calculations and the corresponding fluence-to-dose conversion coefficients. The measured dosemeter responses are too high in comparison to the calculated ones (up to similar to 50%), the dosemeter reading gives dose values which are too high by a factor of 1.1-2.2 related to the corresponding fluence-to-dose conversion factors.
  •  