SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Felice Pietro) "

Sökning: WFRF:(Felice Pietro)

  • Resultat 1-10 av 41
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Acuña, G. J., et al. (författare)
  • Teaching about complementarity - proposal of classes for university students - including exercises
  • 2022
  • Ingår i: Complementarity of Variable Renewable Energy Sources. - : Elsevier. - 9780323855273 - 9780323855280 ; , s. 687-713
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • The idea behind this chapter is to provide teachers and students with material that can be used while studying renewable energy sources with special attention paid to their complementary characteristics. The questions and exercises included below refer to chapters presented in the book. In case of any questions, we provide the readers with contact details to chapters corresponding authors who would be happy in assisting you in case of any queries.
  •  
2.
  • Barausse, Carlo, et al. (författare)
  • POSTERIOR JAW REHABILITATION USING PARTIAL PROSTHESES SUPPORTED BY IMPLANTS 4.0 X 4.0 MM OR LONGER: THREE-YEAR POST-LOADING RESULTS OF A MULTICENTRE RANDOMISED CONTROLLED TRIAL
  • 2019
  • Ingår i: Clinical Trials in Dentistry. - 2784-9015 .- 2785-3039. ; 1, s. 25-36
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE. To evaluate whether 4.0 x 4.0-mm dental implants could be viable alternatives to implants of length at least 8.5 mm when placed in posterior jaws with adequate bone volumes. MATERIALS AND METHODS. One hundred and fifty patients with posterior (premolar and molar areas) jaws having at least 12.5 mm bone height above the mandibular canal or 11.5 mm below the maxillary sinus, as applicable, were randomised according to a paral-lel-group design and received one to three 4.0 mm-long implants or one to three implants which were at least 8.5 mm-long at three treatment centres. All implants had a diameter of 4.0 mm. Implants were loaded with permanent screw-retained prostheses after 4 months. Patients were followed-up until 3-year post-loading, and outcome measures considered were prosthesis and implant failure, any complications, and changes in pe-ri-implant marginal bone levels. RESULTS. Seventy-five patients were randomly allocated to each group. Drop-outs at 3-year post-loading assessment were five patients from the long implant group and three from the short implant group. Up to 3 years post-loadings, three patients lost one 4.0 mm-long implant each, in comparison to two patients who lost one long implant each (difference in proportion =-0.013; 95% CI:-0.079 to 0.054; P = 1). All failures occurred before loading; failed implants were replaced, delaying delivery of two prostheses in each group by several months (difference in proportion = 0; 95% CI:-0.061 to 0.062; P = 1). Five short-implant patients experienced six complications versus the three complications seen in three long implant patients (difference in proportion =-0.026; 95% CI:-0.103 to 0.053; P = 0.719). There were no statistically significant differences between groups in prosthesis failures, implant failures or complications. Patients with short implants lost on average 0.55 mm of peri-implant bone, and patients with longer implants lost 0.61 mm. There were no statistically significant differences between short and long implants in bone level changes up to 3 years (mean difference = 0.05 mm; 95% CI:-0.05 to 0.16; P = 0.221). CONCLUSIONS. Outcomes 3 years after loading were similar with 4.0 x 4.0 mm-long implants and 8.5 x 4.0 mm or longer implants in posterior jaws, in the presence of adequate bone volumes. However, 5 to 10-year post-loading data will be necessary before reliable recommendations can be made. CONFLICT OF INTEREST STATEMENT. Global D (Brignais, France) partially supported this trial and donated the implants and prosthetic components. OsteoBiol (Tecnoss, Giaveno, Italy) donated the biomaterials used for bone augmentation. However, the data property belonged to the authors and neither Global D nor OsteoBiol interfered in any way with the conduct of the trial or the publication of the results.
  •  
3.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2 (all-on-2) flapless-placed mandibular implants supporting cross-arch fixed prostheses: interim data from a 1-year follow-up prospective single cohort study.
  • 2012
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 5:1, s. 49-58
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the clinical outcome of 2 implants placed flapless in fully edentulous mandibles and immediately restored with a metal-resin screw-retained cross-arch prosthesis 1 year after loading.Eighty consecutive patients were recruited. To be immediately loaded, implants had to be inserted with a minimum torque of 80 Ncm. Outcome measures, evaluated by two independent assessors, were prosthesis and implant failures, complications, marginal bone level changes, implant stability quotient (ISQ) values and patient satisfaction.Flaps were raised in 7 patients. Twelve implants in 7 patients did not reach the planned insertion torque. Four implants in 3 patients were immediately replaced by larger diameter implants and achieved the desired torque, whereas the remaining implants were immediately loaded anyway. Two implants failed early in 2 patients, but were successfully replaced and their prostheses remade. One month after loading, 72 (90%) patients declared to be completely satisfied with the therapy, 7 (9%) partially satisfied and 1 (1%) unsatisfied. One year after loading, all prostheses were in function, though one patient did not attend the 1-year control. Eight (10%) complications occurred, all successfully treated. After 1 year, the mean marginal bone loss was 0.3 mm and mean ISQ values decreased from 75.4 to 72.4.These short-term results at 1 year after loading suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only 2 dental implants. Longer follow-ups (around 10 years) are needed to know the prognosis of this treatment modality.
  •  
4.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2(all-on-2) versus 4 (all-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: 1-year results from a pilot randomised controlled trial.
  • 2013
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 6:2, s. 121-31
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the outcome of 2 versus 4 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Sixty patients from two different centres were randomised: 30 to the allon- 2 group and 30 to the all-on-4 group according to a parallel group design. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, complications, and marginal bone level changes.Flaps were raised in 18 patients. A total of 2 implants in 2 patients did not reach the planned insertion torque and were immediately replaced by larger diameter ones. One year after loading, no drop-out or implant failure occurred. Eight biomechanical complications occurred in the all-on-2 group versus 8 complications in the all-on-4 group. There were no statistically significant differences for complications between groups. There were no statistically significant differences for marginal peri-implant bone levels between the two groups (estimate of the difference = -0.16; 95%CI -0.40 to 0.08; P (ANCOVA) = 0.074), with both groups losing a statistically significant amount of marginal bone (0.74 mm for all-on-2 implants and 0.58 mm for all-on-4 implants). There were statistically significant differences between the two centres, with more bone being lost for the Bologna centre (0.26 mm versus 1.07 mm).These preliminary results, up to 1 year after loading, suggest that immediately loaded mandibular cross-arch fixed prostheses can be supported by only 2 dental implants. Longer followups (approximately 10 years) are needed to properly evaluate this therapeutic option.
  •  
5.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of 2 (all-on-2) versus 4 (all-on-4) implants placed with a flapless technique supporting mandibular cross-arch fixed prostheses: preliminary results from a pilot randomised controlled trial.
  • 2011
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 4:3, s. 205-17
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the clinical outcome of 2 implants versus 4 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Sixty patients from two different centres were randomised: 30 to the allon- 2 group and 30 to the all-on-4 group. To be immediately loaded, implants had to be inserted with a minimum torque of 40 Ncm. Outcome measures were prosthesis and implant failures, and biological and biomechanical complications.Flaps were raised in 18 patients. Two implants in 2 patients did not reach the planned insertion torque and were immediately replaced by larger diameter ones. Four months after loading, no drop-out or implant failure occurred. One biomechanical complication occurred in the all-on-2 group versus 4 in the all-on-4 group. There were no statistically significant differences between groups for complications. There were no differences between centres.These very preliminary results, just 4 months after loading, suggest that immediately loaded mandibular cross-arch fixed dental prostheses can be supported by only 2 dental implants. Longer follow-ups (around 10 years) are needed to understand whether cross-arch mandibular prostheses can be successfully supported by only 2 dental implants.
  •  
6.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate loading of fixed cross-arch prostheses supported by flapless-placed 5 mm or 11.5 mm long implants: 5-year results from a randomised controlled trial.
  • 2018
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 11:3, s. 295-306
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare the outcome of cross-arch prostheses supported either by 5 mm long or 11.5 mm long implants placed flapless and immediately restored with a metal-resin screw-retained cross-arch prostheses.Thirty patients with edentulous or to-be- rendered edentulous mandibles, and 30 with edentulous maxillas, having sufficient bone to allow the placement of four and six implants respectively, of at least 11.5 mm long, were randomised according to a parallel group design into two equal groups and received either 5 mm or 11.5 mm long implants at one centre. Implants had a diameter of 5 mm, were to be placed flapless, and with an insertion torque of at least 50 Ncm. Mandibles received four implants between the mental foramina. Implants were to be immediately loaded with metal-resin definitive prostheses the same day as implant placement. Patients were followed to 5 years post-loading and the outcome measures were: prosthesis and implant failures, complications, and peri-implant marginal bone level changes.Four patients per group dropped out. Two prostheses were remade, one on short maxillary implants and one on long mandibular implants (difference in proportions = 0; 95% CI: -0.15 to 0.15; P = 1.000). Three patients lost six short implants vs three patients who lost four long implants (difference in proportions = 0; 95% CI: -0.19 to 0.19; P = 1.000). Four short implant patients were affected by complications vs five patients with long implants (difference in proportions = 0.04; 95% CI: -0.17 to 0.25; P = 1.000). There were no statistically significant differences for prostheses failures, implant failures and complications. Patients with mandibular short implants lost on average 0.22 mm of peri-implant bone at 5 years while patients with long mandibular implants lost 0.83 mm. Patients with maxillary short implants lost on average 0.30 mm of peri-implant bone at 5 years and patients with long maxillary implants lost 0.89 mm. Short implants showed less bone loss when compared with long implants and the differences up to 5 years were statistically significant both in maxillae (mean difference = 0.59 mm, 95% CI: 0.33 to 0.86 mm, P < .0001) and in mandibles (mean difference = 0.61 mm, 95% CI: 0.36 to 0.86 mm, P < 0.0001).Flapless-placed 5 mm long implants achieved similar results as 11.5 mm long implants when supporting immediately loaded cross-arch prostheses both in maxillae and mandibles up to 5 years after loading. These results must be confirmed by other trials, and 10 years post-loading data is necessary before making reliable recommendations.
  •  
7.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomised clinical trial.
  • 2010
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 3:2, s. 111-20
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether immediate non-occlusal loading of single zirconia implants could reduce early failures when compared to immediate occlusal loading. MATERIALS AND METHODS: Forty partially edentulous patients who received one single zirconia implant (Z-Systems) at least 10 mm long and 3.25 mm wide inserted with a torque of at least 35 Ncm were randomised to immediate occlusal or non-occlusal loading groups. All patients received provisional acrylic crowns the same day of implant placement. Provisional crowns were replaced after 4 to 5 months by definitive full ceramic crowns. Outcome measures were implant success, any complications and peri-implant marginal bone levels. RESULTS: One year after loading, no patients had dropped out. Five implants (12.5%) failed early: three occlusally loaded and two non-occlusally loaded. Three complications occurred, all after delivery of the definitive crowns: one crown fractured (occlusal loading), one had to be remade after debridement because of hyperplastic tissues (occlusal loading), and one crown decemented (nonocclusal loading). These differences were not statistically significant. Both groups gradually lost periimplant bone in a highly statistically significant way. One year after loading, patients subjected to non-occlusal loading lost an average of 0.7 mm of peri-implant bone versus 0.9 mm in the occlusal group. This difference in bone loss between groups was not statistically significant. There was an association between immediate post-extractive implants and implant failures (P=0.01). Four of the 10 immediate post-extractive implants (40%) failed versus one out of 30 delayed implants (3%). CONCLUSIONS: The results of this study do not provide a conclusive answer to whether immediate non-occlusal loading may decrease implant failures. Immediately loaded zirconia implants placed in post-extractive sites had high failure rates.
  •  
8.
  • Cannizzaro, Gioacchino, et al. (författare)
  • Immediate vs early loading of 6.6 mm flapless-placed single implants: 9 years after-loading report of a split-mouth randomised controlled trial.
  • 2018
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 11:2, s. 163-173
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the long-term effectiveness of 6.6 mm long flapless-placed single implants loaded immediately or early loaded at 6 weeks.Thirty patients each received two single Nanotite External Hex Biomet 3i implants, which were then randomly allocated to be either immediately or early loaded, according to a split-mouth design. Implants had to be inserted with a torque superior to 40 Ncm. Provisional crowns were put in slight occlusal contact and replaced by definitive crowns 3 months after loading. Patients were followed for 9 years after loading. Outcome measures were implant failures, biological and biomechanical complications, peri-implant marginal bone level changes and patient preference.A total of 29 implants were immediately loaded, while 31 were early loaded. Nine years after loading, three patients dropped out. One implant failed in each group within 2 months after loading. One patient asked for the immediately loaded crown to be remade for aesthetic reasons and then again to have both metal-ceramic crowns replaced by full ceramic crowns. Another patient had his immediately loaded crown remade after repeated debonding. Six patients from each group experienced complications, the difference being not statistically significant (difference of proportions = 0.00; 95% CI -0.20 to 0.20, P = 1.000). Peri-implant bone loss was 0.60 mm for patients with immediately loaded implants and 0.46 mm for early loaded ones, which was not significantly different (mean difference = 0.14 mm, 95% CI -0.13 to 0.41, P = 0.283). All but one patient had no preference for either procedure after 9 years.Flapless-placed 6.6 mm long single implants can be immediately loaded and remain successful up to 9 years after loading. Conflict-of-interest statement:
  •  
9.
  • Checchi, Luigi, et al. (författare)
  • Crestal sinus lift for implant rehabilitation: a randomised clinical trial comparing the Cosci and the Summers techniques. A preliminary report on complications and patient preference
  • 2010
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 3:3, s. 221-232
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare the effectiveness of two different techniques to lift the maxillary sinus via a crestal approach: the Summers versus the Cosci technique. MATERIALS AND METHODS: Fifteen partially edentulous patients missing bilaterally maxillary molars and/ or premolars having 4 to 7 mm of residual crestal height and at least 5 mm thickness below the maxillary sinuses measured on computed tomography scans were randomised to have implants placed in sinuses crestally lifted according to the Cosci or Summers technique with bone substitutes according to a split-mouth design. Implants were left to heal submerged for 6 months. Implants were loaded with acrylic provisional crowns/prostheses. Screw-retained definitive metal-ceramic prostheses were delivered 4 months after provisional loading. Outcome measures were prosthesis and implant failures, any complications, operation time, operator preference, and patient preference assessed 1 month after surgery and 1 month after delivery of the final prostheses by a blinded outcome assessor. All patients were followed up to 5 months after loading (1 year after implant placement). RESULTS: Nineteen study implants were placed according to each technique. No patient dropped out and no implant failed. No discomfort/complications occurred at sites treated with the Cosci technique whereas 12 patients reported discomfort during the augmentation procedure at the side treated with the Summers technique, this was statistically significant, and in one of these patients a perforation of the sinus membrane occurred. Postoperatively, headache was reported by nine patients and swelling occurred in three of these patients at the Summers treated sides. Statistically significantly less time was required to place implants according to the Cosci technique (33 versus 24 minutes, on average). The two operators and 14 out of 15 patients preferred the Cosci technique. CONCLUSIONS: Both crestal sinus lift techniques were successful but the Cosci technique required less surgical time, produced less intra- and postoperative morbidity and was preferred by patients.
  •  
10.
  • Davó, Rubén, et al. (författare)
  • Immediately loaded zygomatic implants vs conventional dental implants in augmented atrophic maxillae: 1-year post-loading results from a multicentre randomised controlled trial.
  • 2018
  • Ingår i: European journal of oral implantology. - 1756-2406. ; 11:2, s. 145-161
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare the clinical outcome of immediately loaded cross-arch maxillary prostheses supported by zygomatic implants vs conventional implants placed in augmented bone.In total, 71 edentulous patients with severely atrophic maxillas without sufficient bone volumes for placing dental implants, or when it was possible to place only two implants in the anterior area (minimal diameter 3.5 mm and length of 8 mm) and less than 4 mm of bone height subantrally, were randomised according to a parallel group design to receive zygomatic implants (35 patients) to be loaded immediately vs grafting with a xenograft, followed after 6 months of graft consolidation by placement of six to eight conventional dental implants submerged for 4 months (36 patients). For immediate loading, zygomatic implants had to be inserted with an insertion torque superior to 40 Ncm. Screw-retained metal reinforced acrylic provisional prostheses were provided, to be replaced by definitive Procera Implant Bridge Titanium prostheses (Nobel Biocare, Göteborg, Sweden), with ceramic or acrylic veneer materials 4 months after initial loading. Outcome measures were: prosthesis, implant and augmentation failures, any complications, quality of life (OHIP-14), patients' number of days with total or partial impaired activity, time to function and number of dental visits, assessed by independent assessors. Patients were followed up to 1 year after loading.No augmentation procedure failed. Five patients dropped out from the augmentation group. Six prostheses could not be delivered or failed in the augmentation group vs one prosthesis in the zygomatic group, the difference being statistically significant (difference in proportions = -16.5%; P = 0.045; 95% CI: -0.34 to -0.01). Eight patients lost 35 implants in the augmentation group vs two patients who lost four zygomatic implants, the difference being statistically significant (difference in proportions = -20.1%; P = 0.037; 95% CI: -0.38 to -0.02). A total of 14 augmented patients were affected by 22 complications, vs 28 zygomatic patients (40 complications), the difference being statistically significant (difference in proportions = 34.8%; P = 0.005; 95% CI: 0.12 to 0.54). The 1-year OHIP-14 score was 3.93 ± 5.86 for augmented patients and 3.97 ± 4.32 for zygomatic patients with no statistically significant differences between groups (mean difference = 0.04; 95% CI: -2.56 to 2.65; P = 0.747). Both groups had significantly improved OHIP-14 scores from before rehabilitation (P < 0.001 for both augmented and zygomatic patients). On average, the number of days of total infirmity was 7.42 ± 3.17 for the augmented group and 7.17 ± 1.96 for the zygomatic group, the difference not being statistically significant (mean difference = -0.25; 95% CI: -1.52 to 1.02; P = 0.692). The number of days of partial infirmity were on average 14.24 ± 4.64 for the augmented group and 12.17 ± 3.82 for the zygomatic group, the difference being statistically significant (mean difference = -2.07; 95% CI: -4.12 to -0.02; P = 0.048). The mean number of days that needed to have a functional prosthesis was 444.32 ± 207.86 for augmented patients and 1.34 ± 2.27 for zygomatic patients, the difference being statistically significant (mean difference = -442.98; 95% CI: -513.10 to -372.86; P < 0.001). The average number of dental visits was 19.72 ± 12.22 for augmented patients and 15.12 ± 5.76 for zygomatic patients, the difference not being statistically significant (mean difference = -4.61; 95% CI: -9.31 to 0.92; P = 0.055).Preliminary 1-year post-loading data suggest that immediately loaded zygomatic implants were associated with statistically significantly fewer prosthetic failures (one vs six patients), implant failures (two vs eight patients) and time needed to functional loading (1.3 days vs 444.3 days) when compared to augmentation procedures and conventionally loaded dental implants. Even if more complications were reported for zygomatic implants, they proved to be a better rehabilitation modality for severely atrophic maxillae. Long-term data are absolutely needed to confirm or dispute these preliminary results.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 41
Typ av publikation
tidskriftsartikel (38)
forskningsöversikt (2)
bokkapitel (1)
Typ av innehåll
refereegranskat (39)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Esposito, Marco, 196 ... (38)
Felice, Pietro (38)
Pistilli, Roberto (19)
Barausse, Carlo (18)
Cannizzaro, Gioacchi ... (10)
Soardi, Elisa (8)
visa fler...
Ippolito, Daniela Ri ... (7)
Pellegrino, Gerardo (7)
Buti, Jacopo (5)
Grusovin, Maria Gabr ... (5)
Leone, Michele (5)
Ferri, Vittorio (4)
Lazzarini, Matteo (3)
Gastaldi, Giorgio (3)
Checchi, Luigi (3)
Velasco-Ortega, Euge ... (2)
Torchio, Cinzia (2)
Trullenque-Eriksson, ... (2)
De Angelis, Nicola (2)
Camurati, Andrea (2)
Sammartino, Gilberto (2)
Blasone, Rodolfo (2)
Campana, Pietro Elia ... (1)
Gustafsson, Mats (1)
Berger, M. (1)
Acuña, G. J. (1)
Campos, R. A. (1)
Canales, F. A. (1)
Cantor, D. (1)
Ciapała, B. (1)
Cioccolanti, L. (1)
De Felice, M. (1)
de Oliveira Costa So ... (1)
Nordebo, Sven (1)
Davo, Ruben (1)
Worthington, Helen V ... (1)
Linusson, Anna, 1970 ... (1)
Testori, Tiziano (1)
Rcsed, Mperio (1)
Bigagli, Lorenzo (1)
Giorgi, Angelo (1)
Audino, Salvatore (1)
Galli, Fabio (1)
Antonini, Elisa Soar ... (1)
Cosci, Ferdinando (1)
Todisco, Marzio (1)
Marti-Pages, Carlos (1)
Ferrer-Fuertes, Ada (1)
Gambino, Paolo (1)
Cannizarro, Gioacchi ... (1)
visa färre...
Lärosäte
Göteborgs universitet (38)
Umeå universitet (1)
Mälardalens universitet (1)
Lunds universitet (1)
Linnéuniversitetet (1)
Språk
Engelska (41)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (39)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy