SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fernandez Perez Bibiana M.) "

Sökning: WFRF:(Fernandez Perez Bibiana M.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
2.
  • Trinca, Lucia Carmen, et al. (författare)
  • Evaluation of in vitro corrosion resistance and in vivo osseointegration properties of a FeMnSiCa alloy as potential degradable implant biomaterial
  • 2021
  • Ingår i: Materials science & engineering. C, biomimetic materials, sensors and systems. - : Elsevier BV. - 0928-4931 .- 1873-0191. ; 118
  • Tidskriftsartikel (refereegranskat)abstract
    • In vitro electrochemical characterization and in vivo implantation in an animal model were employed to evaluate the degradation behaviour and the biological activity of FeMnSi and FeMnSiCa alloys obtained using UltraCast (Ar atmosphere) melting. Electrochemical characterization was based on open circuit potential measurement, electrochemical impedance spectroscopy and potentiodynamic polarization techniques while the alloys were immersed in Ringer's solution at 37 degrees C for 7 days. Higher corrosion rates were measured for the Cacontaining material, resulting from inefficient passivation of the metal surface by oxy-hydroxide products. In vivo osseointegration was investigated on a tibia implant model in rabbits by referring to a standard control (AISI 316 L) stainless steel using standard biochemical, histological and radiological methods of investigation. Changes in the biochemical parameters were related to the main stages of the bone defect repair, whereas implantation of the alloys in rabbit's tibia provided the necessary mechanical support to the injured bone area and facilitated the growth of the newly connective tissue, as well as osteoid formation and mineralization, as revealed by either histological sections or computed tomography reconstructed images and validated by the bone morphometric indices. The present study highlighted that the FeMnSiCa alloy promotes better osteoinduction and osseconduction processes when compared to the base FeMnSi alloy or with AISI 316 L, and in vivo degradation rates correlate well with corrosion resistance measurements in Ringer's solution.
  •  
3.
  • Colozza, Noemi, et al. (författare)
  • Insights into Tripodal Tris(pyrazolyl) Compounds as Ionophores for Potentiometric Ammonium Ion Sensing
  • 2022
  • Ingår i: ChemElectroChem. - : Wiley. - 2196-0216. ; 9:18
  • Tidskriftsartikel (refereegranskat)abstract
    • The decentralisation of accurate determination of the ammonium ion (NH4+) is relevant for environmental monitoring (i. e., nitrogen cycle) and certain clinical applications (e. g., kidney and liver diseases). Potentiometric ionophore-based sensors are one alternative for these purposes in terms of versatile implementation, though the potassium ion (K+) is known to be a major source of interference. We herein investigate the use of three different tripodal tris(pyrazolyl) compounds derived from 1,3,5-triethylbenzene as NH4+ ionophores. A complete set of potentiometric experiments together with theoretical simulations reveals suitable analytical performance while demonstrating a suppression of the K+ interference given the formation of an adequate cavity in the ionophore to host NH4+ over K+ in the membrane environment. The results support the use of these electrodes in the analytical detection of NH4+ in a wide range of samples with variable contents.
  •  
4.
  • Cuartero, Maria, et al. (författare)
  • Why ammonium detection is particularly challenging but insightful with ionophore-based potentiometric sensors - an overview of the progress in the last 20 years
  • 2020
  • Ingår i: The Analyst. - : Royal Society of Chemistry (RSC). - 0003-2654 .- 1364-5528. ; 145:9, s. 3188-3210
  • Forskningsöversikt (refereegranskat)abstract
    • The monitoring of ammonium ion concentration has gained the attention of researchers from multiple fields since it is a crucial parameter with respect to environmental and biomedical applications. For example, ammonium is considered to be a quality indicator of natural waters as well as a potential biomarker of an enzymatic byproduct in key physiological reactions. Among the classical analytical methods used for the detection of ammonium ions, potentiometric ion-selective electrodes (ISEs) have attracted special attention in the scientific community because of their advantages such as cost-effectiveness, user-friendly features, and miniaturization ability, which facilitate easy portable measurements. Regarding the analytical performance, the key component of ISEs is the selective receptor, labelled as an ionophore in ISE jargon. Indeed, the preference of an ionophore for ammonium amongst other ions (i.e., selectivity) is a factor that primarily dictates the limit of detection of the electrode when performing measurements in real samples. A careful assessment of the literature for the last 20 years reveals that nonactin is by far the most employed ammonium ionophore to date. Despite the remarkable cross-interference of potassium over the ammonium response of nonactin-based ISEs, analytical applications comprising water quality assessment, clinical tests in biological fluids, and sweat monitoring during sports practice have been successfully researched. Nevertheless, there is evident difficulty in the determination of close-to-micromolar levels of ammonium in real samples with a significant potassium background level (i.e., millimolar concentration). This fact has fostered the search for a large variety of ammonium ionophores over the years, which are critically inspected herein. Overall, we provide an easily readable state of the art accompanied by a comprehensive description of other types of ammonium electrodes, including commercially available units. We conclude that newer breakthroughs are still required in the field to reach the desired analytical applications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy