SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fritioff T) "

Sökning: WFRF:(Fritioff T)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Delahaye, P, et al. (författare)
  • Recent results with the Phoenix booster at ISOLDE
  • 2006
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 77:3, s. 03B105-
  • Tidskriftsartikel (refereegranskat)abstract
    • At ISOLDE, CERN the development of charge breeding techniques is one of the key points for numerous future experiments. We report in this article on the latest online tests of the Daresbury Phoenix booster at ISOLDE. The performances of the continuous mode were investigated for different injected stable beams. Preliminary results were obtained with the afterglow pulsing method and two injected noble gas isotopes. These latter tests are of particular interest for the postacceleration of ISOL-type beams.
  •  
2.
  • Fritioff, T., et al. (författare)
  • Purification of radioactive neutron-rich argon beams using an ion source in charge breeding mode
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576 .- 0167-5087. ; 556:1, s. 31-37
  • Tidskriftsartikel (refereegranskat)abstract
    • Measurements of nuclear properties of some neutron-rich asymmetric fission isotopes at an ISOL laboratory present a severe problem when a plasma ion source is used as the primary ion-source. The problem is associated with intense multi-charged symmetric fission contaminants that cannot be mass-separated from asymmetric fission products. In this work we demonstrate how this problem can be overcome on-line by using an electron cyclotron resonance ion source (ECRIS) as a charge-breeding secondary ion-source. Mixed Ar+/Kr2+/Xe3+ radioactive beams from an plasma ion-source were injected into the PHOENIX ECRIS that currently is installed at the ISOLDE facility at CERN in order to improve the ratio of Ar to the background contaminants of Kr and Xe. The signal to noise ratio was improved by more than two orders of magnitude after charge-breeding and mass-separation of the Ar8+, Ar9+ beams. The information on the decay of the Ar-48 nucleus obtained in these tests is useful for a better understanding of the origin of the Ca-48/Ca-46 meteorite isotopic anomaly. Potential applications of the method are discussed.
  •  
3.
  • Bläckberg, Lisa, et al. (författare)
  • Investigations of surface coatings to reduce memory effect in plastic scintillator detectors used for radioxenon detection
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 656:1, s. 84-91
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work Al(2)O(3) and SiO(2) coatings are tested as Xe diffusion barriers on plastic scintillator substrates. The motivation is improved beta-gamma coincidence detection systems, used to measure atmospheric radioxenon within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty. One major drawback with the current setup of these systems is that the radioxenon tends to diffuse into the plastic scintillator material responsible for the beta detection, resulting in an unwanted memory effect. Here, coatings with thicknesses between 20 and 900 nm have been deposited onto plastic scintillators, and investigated using two different experimental techniques. The results show that all tested coatings reduce the Xe diffusion into the plastic. The reduction is observed to increase with coating thickness for both coating materials. The 425 nm Al(2)O(3) coating is the most successful one, presenting a diffusion reduction of a factor 100, compared to uncoated plastic. In terms of memory effect reduction this coating is thus a viable solution to the problem in question.
  •  
4.
  • Bläckberg, Lisa, et al. (författare)
  • Memory effect, resolution, and efficiency measurements of an Al2O3 coated plastic scintillator used for radioxenon detection
  • 2013
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 714, s. 128-135
  • Tidskriftsartikel (refereegranskat)abstract
    • A cylindrical plastic scintillator cell, used for radioxenon monitoring within the verification regime of the Comprehensive Nuclear-Test-Ban Treaty, has been coated with 425 nm Al2O3 using low temperature Atomic Layer Deposition, and its performance has been evaluated. The motivation is to reduce the memory effect caused by radioxenon diffusing into the plastic scintillator material during measurements, resulting in an elevated detection limit. Measurements with the coated detector show both energy resolution and efficiency comparable to uncoated detectors, and a memory effect reduction of a factor of 1000. Provided that the quality of the detector is maintained for a longer period of time, Al2O3 coatings are believed to be a viable solution to the memory effect problem in question.
  •  
5.
  • Hobein, Matthias, 1981-, et al. (författare)
  • Optimization of the Stockholm R-EBIT for the production and extraction of highly charged ions
  • 2010
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 5:C11003
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a refrigerated EBIT (R-EBIT) commissioned at the AlbaNova Research Center at Stockholm University. As an innovative solution, the superconducting magnet and the trapping drift tubes of the R-EBIT are cooled to a temperature of 4 K by a set of two cooling heads connected to helium compressors. This dry, i.e. liquid helium and liquid nitrogen free, system is easily operated and creates highly charged ions at a fraction of the cost of traditional liquid-cooled systems. A pulsed and continuous gas injection system was developed to feed neutral particles into the electron beam in the trap region. This improves significantly the highly charged ion production and R-EBIT performance. Fast extraction of ions from the R-EBIT yields very short ( < 100 ns), charge-separated ion bunches which can be either analysed using a straight time-of-flight section or sent to experimental beam lines following selection in a bending magnet. An emittance meter was used to measure the emittance of the ions extracted from the R-EBIT. The extracted ions were also re-trapped in a cylindrical Penning trap and properties of the re-trapped ions have been measured using the emittance meter. Results of these measurements are reported in this publication.
  •  
6.
  • Nagy, Sz, et al. (författare)
  • High-precision mass measurements for fundamental applications using highly-charged ions with SMILETRAP
  • 2007
  • Ingår i: Journal of Physics, Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 58, s. 109-112
  • Tidskriftsartikel (refereegranskat)abstract
    • The Penning trap mass spectrometer SMILETRAP takes advantage of highly-charged ions for high-accuracy mass measurements. In this paper recent mass measurements on Li and Ca ions are presented and their impact on fundamental applications discussed, especially the need for accurate mass values of hydrogen-like and lithium-like ions in the evaluation of the electron g-factor measurements in highly-charged ions is emphasized. Such experiments aim to test bound state quantum electrodynamics. Here the ionic mass is a key ingredient, which can be the limiting factor for the final precision.
  •  
7.
  • Nagy, Sz., et al. (författare)
  • New Mass Value for 7Li
  • 2006
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 96:16, s. 163004-
  • Tidskriftsartikel (refereegranskat)
  •  
8.
  •  
9.
  • Nagy, Sz, et al. (författare)
  • Precision mass measurements of 40Ca17+ and 40Ca19+ ions in a Penning trap
  • 2006
  • Ingår i: European Physical Journal D. - : Springer Science and Business Media LLC. - 1434-6060 .- 1434-6079. ; 39:1, s. 1-4
  • Tidskriftsartikel (refereegranskat)abstract
    • High-precision mass measurements on lithium-like and hydrogen-like 40Ca-ions are reported. The obtained mass of the hydrogen-like and lithium-like ion is 39.952181819(29) u and 39.953272223(24) u, respectively. The corresponding mass of the 40Ca atom is 39.962590858(22) u. This new value has a precision ten times higher than the literature value.
  •  
10.
  • Schuch, R., et al. (författare)
  • Precise Atomic Masses for Fundamental Physics Determined at SMILETRAP
  • 2008
  • Ingår i: Advances in Quantum Chemistry. - Nederländerna : Elsevier. - 0065-3276 .- 2162-8815. ; 53, s. 67-81
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper we describe the features of the SMILETRAP Penning trap mass spectrometer and give examples of recently performed precision mass measurements. SMILETRAP is designed for precision mass measurements using the merits of highly-charged ions. We emphasize here the importance of accurate masses of hydrogen-like and lithium-like ions for the evaluation of g-factor measurements of electrons bound to even–even nuclei and test quantum electrodynamics (QED). For these experiments the ion masses of 40Ca17+ and 40Ca19+ were measured at SMILETRAP with 5×10−10 precision. Highly precise mass measurements can also be used for testing atomic structure calculations and determination of atomic and nuclear binding energies. Some Q-values are of fundamental interest, for example, the beta-decay of tritium and the double beta-decay with no neutrinos of several nuclei, in particular 76Ge. These decays are related to properties of the electron neutrino mass and whether this neutrino is a Majorana particle. The reason that Penning traps are so reliable for the determinations of accurate decay Q-values is due to the fact that systematic errors to a great deal cancel in the mass difference between the two atoms defining the Q-value. In this paper we report the most accurate Q-values of these two beta decays namely 18589.8(12) eV for the tritium decay, and 2038.997(46) keV for the neutrinoless double beta-decay of 76Ge.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy