  • Elyas, Eli, et al. (författare)
  • Multi-Channel Optical Coherence Elastography Using Relative and Absolute Shear-Wave Time of Flight
  • 2017
  • Ingår i: PLOS ONE. - : PUBLIC LIBRARY SCIENCE. - 1932-6203. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Elastography, the imaging of elastic properties of soft tissues, is well developed for macroscopic clinical imaging of soft tissues and can provide useful information about various pathological processes which is complementary to that provided by the original modality. Scaling down of this technique should ply the field of cellular biology with valuable information with regard to elastic properties of cells and their environment. This paper evaluates the potential to develop such a tool by modifying a commercial optical coherence tomography (OCT) device to measure the speed of shear waves propagating in a three-dimensional (3D) medium. A needle, embedded in the gel, was excited to vibrate along its long axis and the displacement as a function of time and distance from the needle associated with the resulting shear waves was detected using four M-mode images acquired simultaneously using a commercial four-channel swept-source OCT system. Shear-wave time of arrival (TOA) was detected by tracking the axial OCT-speckle motion using cross-correlation methods. Shear-wave speed was then calculated from inter-channel differences of TOA for a single burst (the relative TOA method) and compared with the shear-wave speed determined from positional differences of TOA for a single channel over multiple bursts (the absolute TOA method). For homogeneous gels the relative method provided shear-wave speed with acceptable precision and accuracy when judged against the expected linear dependence of shear modulus on gelatine concentration (R-2 = 0.95) and ultimate resolution capabilities limited by 184 mu m inter-channel distance. This overall approach shows promise for its eventual provision as a research tool in cancer cell biology. Further work is required to optimize parameters such as vibration frequency, burst length and amplitude, and to assess the lateral and axial resolutions of this type of device as well as to create 3D elastograms.
  •  
2.
  • Listz Maurice, Roch, et al. (författare)
  • Characterization of atherosclerotic plaques and mural thrombi with intravascular ultrasound elastography : A potential method evaluated in an aortic rabbit model and a human coronary artery
  • 2008
  • Ingår i: IEEE transactions on information technology in biomedicine. - : Institute of Electrical and Electronics Engineers (IEEE). - 1089-7771 .- 1558-0032. ; 12:3, s. 290-298
  • Tidskriftsartikel (refereegranskat)abstract
    • Plaque rupture is correlated with the plaque morphology, composition, mechanical properties, and with the blood pressure. Whereas the geometry can accurately be assessed with intravascular ultrasound (IVUS) imaging, intravascular elastography (IVE) is capable of extracting information on the plaque local mechanical properties and composition. This paper reports additional IVE validation data regarding reproducibility and potential to characterize atherosclerotic plaques and mural thrombi. In a first investigation, radio frequency (RF) data were acquired from the abdominal aorta of an atherosclerotic rabbit model. In a second investigation, IVUS RF data were recorded from the left coronary artery of a patient referred for angioplasty. In both cases, Galaxy IVUS scanners (Boston Scientific, Freemont, CA), equipped with 40 MHz Atlantis catheters, were used. Elastograms were computed using two methods, the Lagrangian speckle model estimator (LSME) and the scaling factor estimator (SFE). Corroborated with histology, the LSME and the SFE both clearly detected a soft thrombus attached to the vascular wall. Moreover, shear elastograms, only available with the LSME, confirmed the presence of the thrombus. Additionally, IVE was found reproducible with consistent elastograms between cardiac cycles (CCs). Regarding the human dataset, only the LSME was capable of identifying a plaque that presumably sheltered a lipid core. Whereas such an assumption could not be certified with histology, radial shear and tangential strain LSME elastograms enabled the same conclusion. It is worth emphasizing that this paper reports the first ever in vivo tangential strain elastogram with regards to vascular imaging, due to the LSME. It is concluded that the IVE was reproducible exhibiting consistent strain patterns between CCs. The IVE might provide a unique tool to assess coronary wall lesions.
  •  