1.
  • Beal, Jacob, et al. (författare)
  • Robust estimation of bacterial cell count from optical density
  • 2020
  • Ingår i: Communications Biology. - : Springer Science and Business Media LLC. - 2399-3642. ; 3:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data.
  •  
2.
  •  
3.
  • 2019
  • Tidskriftsartikel (refereegranskat)
  •  
4.
  • Hu, Shih-Cheng, et al. (författare)
  • Energy savings approaches for high-tech manufacturing factories
  • 2020
  • Ingår i: CASE STUDIES IN THERMAL ENGINEERING. - : ELSEVIER. - 2214-157X. ; 17
  • Tidskriftsartikel (refereegranskat)abstract
    • This study integrates a fab energy simulation (FES) tool and energy conversion factors to analyze energy consumption and identify energy savings opportunities of high-tech manufacturing factories. The data used is the 169,124 MW h annual energy consumption of a Taiwanese semiconductor manufacturing fab. We proposed a compressed/clean dry air (CDA) system as a two-pressure system using a heated-type dryer. The proposed method achieved 3050 MW h as the highest energy savings in the CDA system compared to the original fab data. The results also indicate that lowering the make-up air unit (MAU) operating temperature caused significant energy savings for the high-temperature water chiller system. When the outlet air temperature of the MAU system was 14 degrees C, the maximum energy savings were 3532 MW h. In addition, the process cooling water (PCW) system could potentially save energy by reducing the pumping head of water in its open system. Therefore, we suggested a closed PCW system that reached a maximum energy saving of 1541 MW h.
  •  