SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fukumura A.) "

Sökning: WFRF:(Fukumura A.)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Vatnitsky, S, et al. (författare)
  • Proton dosimetry intercomparison based on the ICRU report 59 protocol
  • 1999
  • Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 51:3, s. 273-279
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE:A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors.MATERIALS AND METHODS:Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations.RESULTS:The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type.CONCLUSIONS:Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.
  •  
2.
  • Nowak-Sliwinska, Patrycja, et al. (författare)
  • Consensus guidelines for the use and interpretation of angiogenesis assays
  • 2018
  • Ingår i: Angiogenesis. - : Springer. - 0969-6970 .- 1573-7209. ; 21:3, s. 425-532
  • Forskningsöversikt (refereegranskat)abstract
    • The formation of new blood vessels, or angiogenesis, is a complex process that plays important roles in growth and development, tissue and organ regeneration, as well as numerous pathological conditions. Angiogenesis undergoes multiple discrete steps that can be individually evaluated and quantified by a large number of bioassays. These independent assessments hold advantages but also have limitations. This article describes in vivo, ex vivo, and in vitro bioassays that are available for the evaluation of angiogenesis and highlights critical aspects that are relevant for their execution and proper interpretation. As such, this collaborative work is the first edition of consensus guidelines on angiogenesis bioassays to serve for current and future reference.
  •  
3.
  • Ferraro, Gino B., et al. (författare)
  • Fatty acid synthesis is required for breast cancer brain metastasis
  • 2021
  • Ingår i: Nature Cancer. - : Springer Science and Business Media LLC. - 2662-1347. ; 2:4, s. 414-428
  • Tidskriftsartikel (refereegranskat)abstract
    • Brain metastases are refractory to therapies that control systemic disease in patients with human epidermal growth factor receptor 2-positive breast cancer and the brain microenvironment contributes to this therapy resistance. Nutrient availability can vary across tissues, therefore metabolic adaptations required for brain metastatic breast cancer growth may introduce liabilities that can be exploited for therapy. Here we assessed how metabolism differs between breast tumors in brain versus extracranial sites and found that fatty acid synthesis is elevated in breast tumors growing in the brain. We determine that this phenotype is an adaptation to decreased lipid availability in the brain relative to other tissues, resulting in site-specific dependency on fatty acid synthesis for breast tumors growing at this site. Genetic or pharmacological inhibition of fatty acid synthase reduces human epidermal growth factor receptor 2-positive breast tumor growth in the brain, demonstrating that differences in nutrient availability across metastatic sites can result in targetable metabolic dependencies.
  •  
4.
  •  
5.
  • Zeitlin, C., et al. (författare)
  • Fragmentation Cross Sections of Medium-Energy 35Cl, 40Ar, and 48Ti Beams on Elemental Targets
  • 2008
  • Ingår i: Physical Review. ; :C77, s. 034605-
  • Tidskriftsartikel (refereegranskat)abstract
    • Charge-changing and fragment production cross sections at 0 degrees have been obtained for interactions of 290, 400, and 650 MeV/nucleon 40Ar beams, 650 and 1000 MeV/nucleon 35Cl beams, and a 1000 MeV/nucleon 48Ti beam. Targets of C, CH2, Al, Cu, Sn, and Pb were used. Using standard analysis methods, we obtain fragment cross sections for charges as low as 8 for Cl and Ar beams, and as low as 10 for the Ti beam. Using data obtained with small-acceptance detectors, we report fragment production cross sections for charges as low as 5, corrected for acceptance using a simple model of fragment angular distributions. With the lower-charged fragment cross sections, we cancompare the data to predictions from several models (including NUCFRG2, EPAX2, and PHITS) in a region largely unexplored in earlier work. As found in earlier work with other beams, NUCFRG2 and PHITS predictions agree reasonably well with the data for charge-changing cross sections, but do not accurately predict the fragment production cross sections. The cross sections for the lightest fragments demonstrate the inadequacy of several models in which the cross sections fall monotonically with the charge of the fragment. PHITS, despite not agreeing particularly well with the fragment production cross sections on average, nonetheless qualitatively reproduces somesignificant features of the data that are missing from the other models.
  •  
6.
  • Zeitlin, C., et al. (författare)
  • Nuclear fragmentation database for GCR transport code development
  • 2010
  • Ingår i: Advances in Space Research. - : Elsevier BV. - 1879-1948 .- 0273-1177. ; 46:6, s. 728-734
  • Tidskriftsartikel (refereegranskat)abstract
    • A critical need for NASA is the ability to accurately model the transport of heavy ions in the Galactic Cosmic Rays (GCR) through matter, including spacecraft walls, equipment racks, etc. Nuclear interactions are of great importance in the GCR transport problem, as they can cause fragmentation of the incoming ion into lighter ions. Since the radiation dose delivered by a particle is proportional to the square of (charge/velocity), fragmentation reduces the dose delivered by incident ions. The other mechanism by which dose can be reduced is ionization energy loss, which can lead to some particles stopping in the shielding. This is the conventional notion of shielding, but it is not applicable to human spaceflight since the particles in the GCR tend to be too energetic to be stopped in the relatively thin shielding that is possible within payload mass constraints. Our group has measured a large number of fragmentation cross sections, intended to be used as input to, or for validation of, NASA's radiation transport models. A database containing over 200 charge-changing cross sections and over 2000 fragment production cross sections has been compiled. In this report, we examine in detail the contrast between fragment measurements at large acceptance and small acceptance. We use output from the PHITS Monte Carlo code to test our assumptions using as an example Ar-40 data (and simulated data) at a beam energy of 650 MeV/nucleon. We also present preliminary analysis in which isotopic resolution was attained for beryllium fragments produced by beams of B-10 and B-11. Future work on the experimental data set will focus on extracting and interpreting production cross sections for light fragments. (C) 2010 COSPAR. Published by Elsevier Ltd. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy