SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gäbel Jakob 1971) "

Sökning: WFRF:(Gäbel Jakob 1971)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bartfay, Sven-Erik, et al. (författare)
  • Are biventricular assist devices underused as a bridge to heart transplantation in patients with a high risk of postimplant right ventricular failure?
  • 2017
  • Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 0022-5223 .- 1097-685X. ; 153:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Right ventricular failure in patients treated using left ventricular assist devices is associated with poor outcomes. We assessed the strategy of preplanned biventricular assist device implantation in patients with a high risk for right ventricular failure.Between 2010 and 2014, we assigned 20 patients to preplanned biventricular assist device and 21 patients to left ventricular assist device as a bridge to heart transplantation on the basis of the estimated risk of postimplant right ventricular failure. Preimplant characteristics and postimplant outcomes were compared between the 2 groups.Patients with a biventricular assist device were younger, more often female, and more frequently had nonischemic heart disease than left ventricular assist device recipients. At preoperative assessment, biventricular assist device recipients had poorer Interagency Registry for Mechanically Assisted Circulatory Support profiles, a lower cardiac index, and more compromised right ventricular function. Survival on device to heart transplantation/weaning/destination for biventricular assist device and left ventricular assist device recipients was 90% versus 86% (not significant), with shorter heart transplantation waiting times for biventricular assist device recipients (median days, 154 vs 302, P<.001). Overall survival at 1year was 85% (95% confidence interval, 62-95) versus 86% (95% confidence interval, 64-95) (not significant). The majority of both biventricular assist device and left ventricular assist device recipients could be discharged to home during the heart transplantation waiting time (55% vs 71%, not significant), and complication rates on device were comparable between groups (major stroke 10% vs 10%, not significant).Planned in advance, the biventricular assist device seems to be a feasible option as bridge to heart transplantation for patients with a high risk of postimplant right ventricular failure. The outcomes for these patients were similarto those observed for contemporary left ventricular assist device recipients, despite those receiving biventricular assist devices being more severely ill.
  •  
2.
  • Dellgren, Göran, 1961, et al. (författare)
  • Continuous improvement in outcome after heart transplantation - Long-term follow-up after three decades of experience.
  • 2017
  • Ingår i: International journal of cardiology. - : Elsevier BV. - 1874-1754 .- 0167-5273. ; 231, s. 188-194
  • Forskningsöversikt (refereegranskat)abstract
    • Heart transplantation (HTx) has become the standard treatment for patients with end-stage heart disease. We report on the long-term outcome after HTx at our centre and investigate trends in outcome over time.During the period, between 1984 and 2014, a total of 610 HTx procedures were performed in 595 patients (median 48years; IQR 31-57years; range 24days-71years; mean 43years; 75% male) in our institution. Long-term outcome was investigated in the whole cohort, among children (n=76), bridged with mechanical circulatory support (MCS, n=131), re-transplanted (n=17), and concomitant kidney transplantation (n=12).Long-term survival was at 1, 5, 10, 15 and 20years: 86% (95CI 0.83-0.89); 77% (95CI 0.73-0.80); 63% (95CI 0.59-0.68); 48% (95CI 0.43-0.54) and 30% (95CI 0.25-0.36), respectively. The median survival for the whole cohort was 14.1years. Patients transplanted during the most recent time period (2010-2014) had a better survival compared to previous eras, with a 1- and 3-year survival of 94% (95CI 0.89-0.97) and 93% (95CI 0.88-0.96), respectively (p<0.001). However, when survival was analysed for long-term MCS (n=80) versus short term MCS (n=35), there was a significantly poorer survival for the short-term MCS group (p=0.001). Independent predictors of long-term mortality included recipient age (p=0.041); previous smoking (p=0.034); ischemic heart disease (p=0.002); and preoperative ventilator therapy (p=0.004).We have shown that continuous improvement in outcome after HTx still occurs. In the last time era, direct transplantation from short-term MCS was abandoned, which may have inflicted outcome during the last time era.
  •  
3.
  • Gäbel, Jakob, 1971, et al. (författare)
  • Cell salvage of cardiotomy suction blood improves the balance between pro- and anti-inflammatory cytokines after cardiac surgery.
  • 2013
  • Ingår i: European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. - : Oxford University Press (OUP). - 1873-734X. ; 44:3, s. 506-11
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The inflammatory response after cardiac surgery is characterized by a profound release of pro- and anti-inflammatory cytokines. Recent data suggest that the balance between pro- and anti-inflammatory cytokines is of greater importance than the absolute levels. Retransfusion of unwashed cardiotomy suction blood contributes to the inflammatory response, but the balance between pro- and anti-inflammatory cytokines in cardiotomy suction blood and whether cell salvage before retransfusion influences the systemic balance have not been investigated previously. METHODS: Twenty-five coronary artery bypass grafting patients were randomized to either cell salvage of cardiotomy suction blood or no cell salvage before retransfusion. Plasma levels of three anti-inflammatory cytokines [interleukin (IL)-1 receptor antagonist, IL-4 and IL-10] and two proinflammatory cytokines (tumour necrosis factor-alpha and IL-6), and the IL-6-to-IL-10 ratio was measured in cardiotomy suction blood before and after cell salvage, and in the systemic circulation before, during and after surgery. RESULTS: Plasma levels of all cytokines except IL-4 and IL-10 were significantly higher in cardiotomy suction blood than in the systemic circulation. The IL-6-to-IL-10 ratio was 6-fold higher in cardiotomy suction blood than in the systemic circulation [median 10.2 (range 1.1-75) vs 1.7 (0.2-24), P < 0.001]. Cell salvage reduced plasma levels of cytokines in cardiotomy suction blood and improved the systemic IL-6-to-IL-10 ratio 24 h after surgery [median 5.2 (3.6-17) vs 12.4 (4.9-31)] compared with no cell salvage (P = 0.032). CONCLUSIONS: The balance of pro- and anti-inflammatory cytokines in cardiotomy suction blood is unfavourable. Cell salvage reduces the absolute levels of both pro- and anti-inflammatory cytokines in cardiotomy suction blood and improves the balance in the systemic circulation after surgery.
  •  
4.
  • Gäbel, Jakob, 1971, et al. (författare)
  • Cell saver processing mitigates the negative effects of wound blood on platelet function
  • 2016
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172. ; 60:7, s. 901-909
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundWound blood is highly activated and has poor haemostatic properties. Recent data suggest that retransfusion of unwashed wound blood may impair haemostasis. We hypothesized that cell saver processing of wound blood before retransfusion reduces the negative effects. MethodsWound blood was collected from 16 cardiac surgery patients during cardiopulmonary bypass. One portion of the wound blood was processed in a cell saver and one portion left unprocessed. Increasing amounts of unprocessed blood (10% and 20% of the systemic blood volume) or corresponding volumes of processed blood were added ex vivo to whole blood samples from the same patient. Clot formation was assessed by modified thromboelastometry (ROTEM (R)) and platelet function with impedance aggregometry (Multiplate((R))). ResultsAddition of unprocessed wound blood significantly impaired clot formation and platelet aggregability. Cell saver processing before addition did not influence clot formation but abolished completely the negative effects of wound blood on platelet aggregability tested with all agonists. Median adenosine diphosphate-induced platelet aggregation was 51 (25th and 75th percentiles 42-69) when 20% processed cardiotomy suction blood was added vs. 34 (24-52) U when 20% unprocessed blood was added, P < 0.001. The corresponding figures for arachidonic acid-, thrombin receptor activating peptide- and collagen-induced aggregation was 21 (17-51) vs. 13 (10-25) U, 112 (87-128) vs. 78 (65-103) U and 58 (50-73) vs. 33 (28-44) U, respectively, all P < 0.001). ConclusionThe results suggest that cell saver processing before retransfusion mitigates the negative effects of wound blood on platelet function despite that cell saver processing reduces platelet count.
  •  
5.
  • Gäbel, Jakob, 1971, et al. (författare)
  • Retransfusion of cardiotomy suction blood impairs haemostasis: Ex vivo and in vivo studies.
  • 2013
  • Ingår i: Scandinavian cardiovascular journal : SCJ. - : Informa UK Limited. - 1651-2006 .- 1401-7431. ; 47:6, s. 368-376
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives. Cardiotomy suction blood in volumes corresponding to 10-20% of the systemic blood volume is retransfused during cardiopulmonary bypass. We hypothesized that retransfusion of unwashed cardiotomy suction blood influences coagulation and platelet function. Design. Systemic blood samples collected during cardiopulmonary bypass were supplemented ex vivo with autologous wound blood (5, 10 and 20%, respectively). Clot formation and platelet function were assessed with thromboelastometry and platelet aggregometry. In an in vivo pilot study 30 patients were randomized into a retransfusion and a no-retransfusion group. Clot formation, platelet aggregability and thrombin generation capacity were compared between the groups. Results. Cardiotomy suction blood had markedly impaired clot stability and reduced levels of fibrinogen and platelets compared with systemic blood. Ex vivo addition of 10% and 20% suction blood to systemic blood impaired platelet aggregability and clot stability. Retransfusion of small amounts of wound blood in vivo (mean volume 280 ml, corresponding to 5% of the blood volume) did not significantly influence haemostasis. Conclusions. The ex vivo results suggest that addition of unwashed cardiotomy suction blood in clinically relevant volumes impairs systemic haemostasis. Retransfusion of smaller volumes in vivo has no or limited impact. Avoiding retransfusion of larger amounts of unwashed cardiotomy suction may improve postoperative haemostasis.
  •  
6.
  • Kennergren, Charles, 1948, et al. (författare)
  • A single-centre experience of over one thousand lead extractions.
  • 2009
  • Ingår i: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - : Oxford University Press (OUP). - 1532-2092. ; 11:5, s. 612-7
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The aim of the study was to present a single-centre experience of pacemaker and implantable cardioverter defibrillator (ICD) lead extraction using different methods, mainly laser-assisted extraction. METHODS AND RESULTS: Data from 1032 leads and 647 procedures were gathered. A step-by-step approach using different techniques while performing an ongoing risk-benefit analysis was used. The most common indications were local infection, systemic infection, non-functional lead, elective lead replacement, and J-wire fracture. Mean implantation time for all leads was 69 months and for laser-extracted leads 91 months. Laser technique was used to extract 60% of the leads, 29% were manually extracted, 6% extracted with mechanical tools, 4% were surgically removed, and 0.6% extracted by a femoral approach. Failure rate was 0.7%, and major complication rate was 0.9%. No extraction-related mortality occurred. Median time for laser extraction was 2 min. Long implantation time was not a risk factor for failure or for complication. CONCLUSION: Pacing and ICD leads can safely, successfully, and effectively be extracted. Leads can often be extracted by a superior transvenous approach; however, open-chest and femoral extractions are still required. Laser-assisted lead extraction proved to be a useful technique to extract leads that could not be removed by manual traction. The results indicate that the paradigm of abandoning redundant leads, instead of removing them, may have to be reconsidered.
  •  
7.
  • Sartipy, Ulrik, et al. (författare)
  • Cardiac rupture during vacuum-assisted closure therapy.
  • 2006
  • Ingår i: The Annals of thoracic surgery. - : Elsevier BV. - 1552-6259 .- 0003-4975. ; 82:3, s. 1110-1
  • Tidskriftsartikel (refereegranskat)abstract
    • Vacuum-assisted closure therapy is a recently introduced technique for treatment of deep sternal wound infections after cardiac surgery. We present five cases of vacuum-assisted closure therapy-related major bleeding complications due to rupture of the right ventricle. This potentially lethal complication may be avoided by covering the heart with protective layers of paraffin gauze dressings.
  •  
8.
  • Wartig, Maria, et al. (författare)
  • Tricuspid regurgitation influences outcome after heart transplantation.
  • 2014
  • Ingår i: The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. - : Elsevier BV. - 1557-3117. ; 33:8, s. 829-835
  • Tidskriftsartikel (refereegranskat)abstract
    • We investigated the correlation between tricuspid regurgitation (TR) and late survival, and its relation to bicaval (BC) and biatrial (BA) technique, after heart transplantation (HTx).
  •  
9.
  • Westerberg, Martin, et al. (författare)
  • Hemodynamic effects of cardiotomy suction blood.
  • 2006
  • Ingår i: The Journal of thoracic and cardiovascular surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 131:6, s. 1352-7
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: Cardiac surgery induces a systemic inflammatory activation, which in severe cases is associated with peripheral vasodilation and hypotension. Cardiotomy suction blood contains high levels of inflammatory mediators, but the effect of cardiotomy suction blood on the vasculture is unknown. We investigated the effect of cardiotomy suction blood on systemic vascular resistance in vivo and whether cell-saver processing of suction blood affects the vascular response. METHODS: Twenty-five patients undergoing coronary surgery (mean age, 68 +/- 2 years; 80% men) were included in a prospective randomized study. The patients were randomized to retransfusion of cell-saver processed (n = 13) or cell-saver unprocessed (n = 12) suction blood during full cardiopulmonary bypass. Mean arterial blood pressure was continuously registered during retransfusion, and systemic vascular resistance was calculated. Plasma concentrations of tumor necrosis factor alpha, interleukin 6, and complement factor C3a were measured in suction blood. RESULTS: Retransfusion of cardiotomy suction blood induced a transient reduction in systemic vascular resistance in all patients. The peak reduction was significantly less pronounced in the group receiving cell-saver processed blood (-12% +/- 2% vs -28% +/- 3%, P = .001). There was a significant correlation between tumor necrosis factor alpha concentration in retransfused cardiotomy suction blood and peak reduction of systemic vascular resistance (r = 0.60, P = .002). CONCLUSIONS: The results suggest cardiotomy suction blood is vasoactive and might influence vascular resistance and blood pressure during cardiac surgery. The observed vasodilation is proportional to the inflammatory activation of suction blood and can be reduced by processing suction blood with a cell-saving device before retransfusion.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy