SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gadea Andres) "

Sökning: WFRF:(Gadea Andres)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hueyuek, Tayfun, et al. (författare)
  • Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA
  • 2016
  • Ingår i: European Physical Journal A. - : Springer-Verlag New York. - 1434-6001 .- 1434-601X. ; 52:3
  • Tidskriftsartikel (refereegranskat)abstract
    • The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large gamma-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23 l and it is filled with the EJ301 liquid scintillator, that presents good neutron-gamma discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the Ni-58 + Fe-56 reaction measured with the Neutron Wall detector array.
  •  
2.
  •  
3.
  • Javier Egea, Francisco, et al. (författare)
  • Design and Test of a High-Speed Flash ADC Mezzanine Card for High-Resolution and Timing Performance in Nuclear Structure Experiments
  • 2013
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 60:5, s. 3526-3531
  • Tidskriftsartikel (refereegranskat)abstract
    • This work describes new electronics for the EX-OGAM2 (HP-Ge detector array) and NEDA (BC501A-based neutron detector array). A new digitizing card with high resolution has been designed for gamma-ray and neutron spectroscopy experiments. The higher bandwidth requirement of the NEDA signals, together with the necessity for accuracy, require a high sampling rate in order to preserve the shape for real-time Pulse Shape Analysis (PSA). The PSA is of paramount importance for the NEDA to discriminate between neutrons and gamma-ray signals. Both high resolution and high speed parameters are often difficult to achieve in a single electronic unit. These constraints, together with the need to build new digitizing electronics to improve performance and flexibility of signal analysis in nuclear physics experiments, led to the development a new FADC mezzanine card. In this work, the design and development are described, including the characterization procedure and the preliminary measurement results.
  •  
4.
  • Ljungvall, Joa, 1977- (författare)
  • Characterisation of the Neutron Wall and of Neutron Interactions in Germanium-Detector Systems
  • 2005
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • A Monte Carlo simulation of the Neutron Wall detector system has been performed using Geant4, in order to define optimum conditions for the detection and identification of multiple neutrons. Emphasis was put on studying the scattering of neutrons between different detectors, which is the main source of the apparent increase of the number of detected neutrons. The simulation has been compared with experimental data. The quality of neutron gated γ-ray spectra was improved for both two- and three-neutron evaporation channels. The influence of small amounts of γ rays mis-interpreted as neutrons was investigated. It was found that such γ rays dramatically reduce the quality of neutron gated γ-ray spectra.The interaction properties of fast neutrons in a closed-end coaxial and a planar high-purity germanium detector (HPGe) were studied. Digitised waveforms of HPGe preamplifier signals were recorded for time-of-flight separated neutrons and γ rays, emitted by a 252Cf source. The experimental waveforms from the detectors were compared to simulated pulse shapes. In the analysis, special emphasis was given to the detection of elastically scattered neutrons, which may be an important effect to take into account in future spectrometers based on γ-ray tracking. No differences between neutron and γ-ray induced pulse shapes were found in this work.A Monte Carlo simulation of the interactions of fast neutrons in the future 4π γ-ray spectrometer AGATA was also performed, in order to study the influence of neutrons on γ-ray tracking. It was shown that although there is a large probability of detecting neutrons in AGATA, the neutrons decrease the photo-peak efficiency of AGATA by only about 1% for each neutron emitted in coincidence with γ rays. The peak-to-background ratios in γ-ray spectra are, however, reduced to a much larger extent. The possibility of using AGATA as a neutron detector system was also investigated.
  •  
5.
  •  
6.
  • Söderström, Pär-Anders, et al. (författare)
  • Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors
  • 2011
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 638:1, s. 96-109
  • Tidskriftsartikel (refereegranskat)abstract
    • The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected γ-ray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted γ-ray. The γ-ray tracking was used to determine the full energy of the γ-rays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of in the FWHM of the interaction position resolution for the γ-ray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a 30Si beam at 64 MeV on a thin 12C target. Pulse-shape analysis of the digitized detector waveforms and γ-ray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the γ-ray energy and on the energy, axial location and type of the first interaction point, are presented. The FWHM of the interaction position resolution varies roughly linearly as a function of γ-ray energy from 8.5 mm at 250 keV to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the γ-ray energy range from 1.5 to 4 MeV.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy