SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gajda Marianna) "

Sökning: WFRF:(Gajda Marianna)

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gajda, Marianna, et al. (författare)
  • Low-oxidation-potential thiophene-carbazole monomers for electro-oxidative molecular imprinting: Selective chemosensing of aripiprazole
  • 2020
  • Ingår i: Biosensors & bioelectronics. - : ELSEVIER ADVANCED TECHNOLOGY. - 0956-5663 .- 1873-4235. ; 169
  • Tidskriftsartikel (refereegranskat)abstract
    • New thiophene-carbazole functional and cross-linking monomers electropolymerizing at potentials sufficiently low for molecular imprinting of an electroactive aripiprazole antipsychotic drug were herein designed and synthesized. Numerous conducting molecularly imprinted polymer (MIP) films are deposited by electro-polymerization at relatively low potentials by electm-oxidation of pyrmle, aniline, phenol, or 3,4-ethylenediox-ythiophene (EDOT). However, their interactions with templates are not sufficiently strong. Hence, it is necessary to introduce additional recognizing sites in these cavities to increase their affinity to the target molecules. For that, functional monomers derivatized with substituents forming stable complexes with the templates are used. However, oxidation potentials of these derivatives are often, disadvantageously, higher than that of parent monomers. Therefore, we designed and synthesized new functional and cross-linking monomers, which are oxidized at sufficiently low potentials. The deposited MIP and non-imprinted polymer (NIP) films were characterized by PM-IRRAS and UV-vis spectroscopy and imaged with AFM. The structure of the aripiprazole prepolymerization complex with functional monomers was optimized with density functional theory (DFT), and aripiprazole interactions with imprinted cavities were simulated with molecular mechanics (MM) and molecular dynamics (MD). MIP-aripiprazole film-coated electrodes were used as extended gates for selective determination of aripiprazole with the extended-gate field-effect transistor (EG-FET) chemosensor. The linear dynamic concentration range was 30-300 pM, and the limit of detection was 22 fM. An apparent imprinting factor of the MIP-1 was IF = 4.95. The devised chemosensor was highly selective to glucose, urea, and creatinine interferences. The chemosensor was successfully applied for aripiprazole determination in human plasma. The results obtained were compared to those of the validated HPLC-MS method.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy