SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gebel B) "

Sökning: WFRF:(Gebel B)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Eversmann, D., et al. (författare)
  • New Method for a Continuous Determination of the Spin Tune in Storage Rings and Implications for Precision Experiments
  • 2015
  • Ingår i: Physical Review Letters. - 0031-9007 .- 1079-7114. ; 115:9
  • Tidskriftsartikel (refereegranskat)abstract
    • A new method to determine the spin tune is described and tested. In an ideal planar magnetic ring, the spin tune-defined as the number of spin precessions per turn-is given by nu(s) = gamma G (gamma is the Lorentz factor, G the gyromagnetic anomaly). At 970 MeV/c, the deuteron spins coherently process at a frequency of approximate to 120 kHz in the Cooler Synchrotron COSY. The spin tune is deduced from the up-down asymmetry of deuteron-carbon scattering. In a time interval of 2.6 s, the spin tune was determined with a precision of the order 10(-8), and to 1 x 10(-10) for a continuous 100 s accelerator cycle. This renders the presented method a new precision tool for accelerator physics; controlling the spin motion of particles to high precision is mandatory, in particular, for the measurement of electric dipole moments of charged particles in a storage ring.
  •  
4.
  • Guidoboni, G., et al. (författare)
  • How to Reach a Thousand-Second in-Plane Polarization Lifetime with 0.97-GeV/c Deuterons in a Storage Ring
  • 2016
  • Ingår i: Physical Review Letters. - : American Physical Society. - 0031-9007 .- 1079-7114. ; 117:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We observe a deuteron beam polarization lifetime near 1000 s in the horizontal plane of a magnetic storage ring (COSY). This long spin coherence time is maintained through a combination of beam bunching, electron cooling, sextupole field corrections, and the suppression of collective effects through beam current limits. This record lifetime is required for a storage ring search for an intrinsic electric dipole moment on the deuteron at a statistical sensitivity level approaching 10(-29) e cm.
  •  
5.
  • Augustyniak, W., et al. (författare)
  • Polarization of a stored beam by spin-filtering
  • 2012
  • Ingår i: Physics Letters B. - : Elsevier. - 0370-2693 .- 1873-2445. ; 718:1, s. 64-69
  • Tidskriftsartikel (refereegranskat)abstract
    • The PAX Collaboration has successfully performed a spin-filtering experiment with protons at the COSY-ring. The measurement allowed the determination of the spin-dependent polarizing cross section, that compares well with the theoretical prediction from the nucleon-nucleon potential. The test confirms that spin-filtering can be adopted as a method to polarize a stored beam and that the present interpretation of the mechanism in terms of the proton-proton interaction is correct. The outcome of the experiment is of utmost importance in view of the possible application of the method to polarize a beam of stored antiprotons.
  •  
6.
  • Oellers, D., et al. (författare)
  • New experimental upper limit of the electron-proton spin-flip cross-section
  • 2014
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 759, s. 6-9
  • Tidskriftsartikel (refereegranskat)abstract
    • In a previous publication, measurements of the depolarization of a stored proton beam by interaction with a co-propagating unpolarized electron beam at low relative energy have been presented and an upper limit of about 3 x 10(7) b for the electron-proton spin flip cross-section was determined. A refined analysis presented in this paper reduces the previous upper limit by a factor of three by the introduction of a new procedure that, also makes use of non-identified particles.
  •  
7.
  • Tait, Brian D, et al. (författare)
  • Consensus Guidelines on the Testing and Clinical Management Issues Associated With HLA and Non-HLA Antibodies in Transplantation.
  • 2013
  • Ingår i: Transplantation. - 1534-6080. ; 95:1, s. 19-47
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The introduction of solid-phase immunoassay (SPI) technology for the detection and characterization of human leukocyte antigen (HLA) antibodies in transplantation while providing greater sensitivity than was obtainable by complement-dependent lymphocytotoxicity (CDC) assays has resulted in a new paradigm with respect to the interpretation of donor-specific antibodies (DSA). Although the SPI assay performed on the Luminex instrument (hereafter referred to as the Luminex assay), in particular, has permitted the detection of antibodies not detectable by CDC, the clinical significance of these antibodies is incompletely understood. Nevertheless, the detection of these antibodies has led to changes in the clinical management of sensitized patients. In addition, SPI testing raises technical issues that require resolution and careful consideration when interpreting antibody results. METHODS: With this background, The Transplantation Society convened a group of laboratory and clinical experts in the field of transplantation to prepare a consensus report and make recommendations on the use of this new technology based on both published evidence and expert opinion. Three working groups were formed to address (a) the technical issues with respect to the use of this technology, (b) the interpretation of pretransplantation antibody testing in the context of various clinical settings and organ transplant types (kidney, heart, lung, liver, pancreas, intestinal, and islet cells), and (c) the application of antibody testing in the posttransplantation setting. The three groups were established in November 2011 and convened for a "Consensus Conference on Antibodies in Transplantation" in Rome, Italy, in May 2012. The deliberations of the three groups meeting independently and then together are the bases for this report. RESULTS: A comprehensive list of recommendations was prepared by each group. A summary of the key recommendations follows. Technical Group: (a) SPI must be used for the detection of pretransplantation HLA antibodies in solid organ transplant recipients and, in particular, the use of the single-antigen bead assay to detect antibodies to HLA loci, such as Cw, DQA, DPA, and DPB, which are not readily detected by other methods. (b) The use of SPI for antibody detection should be supplemented with cell-based assays to examine the correlations between the two types of assays and to establish the likelihood of a positive crossmatch (XM). (c) There must be an awareness of the technical factors that can influence the results and their clinical interpretation when using the Luminex bead technology, such as variation in antigen density and the presence of denatured antigen on the beads. Pretransplantation Group: (a) Risk categories should be established based on the antibody and the XM results obtained. (b) DSA detected by CDC and a positive XM should be avoided due to their strong association with antibody-mediated rejection and graft loss. (c) A renal transplantation can be performed in the absence of a prospective XM if single-antigen bead screening for antibodies to all class I and II HLA loci is negative. This decision, however, needs to be taken in agreement with local clinical programs and the relevant regulatory bodies. (d) The presence of DSA HLA antibodies should be avoided in heart and lung transplantation and considered a risk factor for liver, intestinal, and islet cell transplantation. Posttransplantation Group: (a) High-risk patients (i.e., desensitized or DSA positive/XM negative) should be monitored by measurement of DSA and protocol biopsies in the first 3 months after transplantation. (b) Intermediate-risk patients (history of DSA but currently negative) should be monitored for DSA within the first month. If DSA is present, a biopsy should be performed. (c) Low-risk patients (nonsensitized first transplantation) should be screened for DSA at least once 3 to 12 months after transplantation. If DSA is detected, a biopsy should be performed. In all three categories, the recommendations for subsequent treatment are based on the biopsy results. CONCLUSIONS: A comprehensive list of recommendations is provided covering the technical and pretransplantation and posttransplantation monitoring of HLA antibodies in solid organ transplantation. The recommendations are intended to provide state-of-the-art guidance in the use and clinical application of recently developed methods for HLA antibody detection when used in conjunction with traditional methods.
  •  
8.
  • Guidoboni, G., et al. (författare)
  • Connection between zero chromaticity and long in-plane polarization lifetime in a magnetic storage ring
  • 2018
  • Ingår i: Physical Review Accelerators and Beams. - : American Physical Society. - 2469-9888. ; 21:2
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we demonstrate the connection between a magnetic storage ring with additional sextupole fields set so that the x and y chromaticities vanish and the maximizing of the lifetime of in-plane polarization (IPP) for a 0.97-GeV/c deuteron beam. The IPP magnitude was measured by continuously monitoring the down-up scattering asymmetry (sensitive to sideways polarization) in an in-beam, carbontarget polarimeter and unfolding the precession of the IPP due to the magnetic anomaly of the deuteron. The optimum operating conditions for a long IPP lifetime were made by scanning the field of the storage ring sextupole magnet families while observing the rate of IPP loss during storage of the beam. The beam was bunched and electron cooled. The IPP losses appear to arise from the change of the orbit circumference, and consequently the particle speed and spin tune, due to the transverse betatron oscillations of individual particles in the beam. The effects of these changes are canceled by an appropriate sextupole field setting.
  •  
9.
  • Hempelmann, N., et al. (författare)
  • Locking the Spin Precession in a Storage Ring
  • 2017
  • Ingår i: Physical Review Letters. - : American Physical Society. - 0031-9007 .- 1079-7114. ; 119:1
  • Tidskriftsartikel (refereegranskat)abstract
    • This Letter reports the successful use of feedback from a spin polarization measurement to the revolution frequency of a 0.97 GeV= c bunched and polarized deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control both the precession rate (approximate to 121 kHz) and the phase of the horizontal polarization component. Real time synchronization with a radio frequency (rf) solenoid made possible the rotation of the polarization out of the horizontal plane, yielding a demonstration of the feedback method to manipulate the polarization. In particular, the rotation rate shows a sinusoidal function of the horizontal polarization phase (relative to the rf solenoid), which was controlled to within a 1 standard deviation range of sigma= 0.21 rad. The minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753 kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a requirement for the use of storage rings to look for an intrinsic electric dipole moment of charged particles.
  •  
10.
  • Hempelmann, N., et al. (författare)
  • Phase measurement for driven spin oscillations in a storage ring
  • 2018
  • Ingår i: Physical Review Accelerators and Beams. - : American Physical Society. - 2469-9888. ; 21:4
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports the first simultaneous measurement of the horizontal and vertical components of the polarization vector in a storage ring under the influence of a radio frequency (rf) solenoid. The experiments were performed at the Cooler Synchrotron COSY in Julich using a vector polarized, bunched 0.97 GeV/c deuteron beam. Using the new spin feedback system, we set the initial phase difference between the solenoid field and the precession of the polarization vector to a predefined value. The feedback system was then switched off, allowing the phase difference to change over time, and the solenoid was switched on to rotate the polarization vector. We observed an oscillation of the vertical polarization component and the phase difference. The oscillations can be described using an analytical model. The results of this experiment also apply to other rf devices with horizontal magnetic fields, such as Wien filters. The precise manipulation of particle spins in storage rings is a prerequisite for measuring the electric dipole moment (EDM) of charged particles.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy