SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gellein Lars Tore) "

Sökning: WFRF:(Gellein Lars Tore)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gellein, Kristin, et al. (författare)
  • Separation of proteins including metallothionein in cerebrospinal fluid by size exclusion HPLC and determination of trace elements by HR-ICP-MS
  • 2007
  • Ingår i: Brain Research. - : Elsevier BV. - 0006-8993 .- 1872-6240. ; 1174, s. 136-142
  • Tidskriftsartikel (refereegranskat)abstract
    • A method to study the protein binding patterns of trace elements in human cerebrospinal fluid (CSF) is described. Proteins in CSF samples were separated by size exclusion chromatography combined with high performance liquid chromatography (SEC-HPLC). The column was calibrated to separate proteins in the molecular weight range 6-70 kDa. Fractions were then analyzed off-line for trace elements using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). We were able to accurately determine more than 10 elements of clinical interest in the CSF fractions. Results are presented for Cd, Mn, Fe, Pb, Cu and Zn. The total concentrations of 16 trace elements in human plasma and CSF are also presented. The method was able to differentiate the relative contribution of metallothionein and other proteins towards metal binding in human CSF.
  •  
2.
  • Schönberg, Tommy, et al. (författare)
  • Surface embedded temperature sensor on tool part for real time injection moulding process monitoring
  • 2013
  • Ingår i: 2013 Transducers and Eurosensors XXVII. - 9781467359818 ; , s. 116-119
  • Konferensbidrag (refereegranskat)abstract
    • This paper reports successful temperature measurements from a real time production process using surface integrated sensors. K-type thermocouples were fabricated directly on the surface of a tool part using Direct Write Thermal Spray and the process temperature cycle from an injection moulding process was measured under real running conditions. The metal-polymer interface never got hotter than 100 °C as the >200 °C molten polymer is instantly solidified as it reaches the cold metal surface.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy