SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gellermann Johanna 1967) "

Sökning: WFRF:(Gellermann Johanna 1967)

  • Resultat 1-10 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Qaiser, Mahmood, 1981, et al. (författare)
  • Unsupervised Segmentation of Head Tissues from Multi-modal MR Images for EEG Source Localization
  • 2015
  • Ingår i: Journal of Digital Imaging. - : Springer Science and Business Media LLC. - 1618-727X .- 0897-1889. ; 28:4, s. 499-514
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we present and evaluate an automatic unsupervised segmentation method, hierarchical segmenta- tion approach (HSA)–Bayesian-based adaptive mean shift (BAMS), for use in the construction of a patient-specific head conductivity model for electroencephalography (EEG) source localization. It is based on a HSA and BAMS for segmenting the tissues from multi-modal magnetic resonance (MR) head images. The evaluation of the proposed method was done both directly in terms of segmentation accuracy and indirectly in terms of source localization accuracy. The direct evaluation was performed relative to a commonly used reference method brain extraction tool (BET)–FMRIB’s automated segmenta- tion tool (FAST) and four variants of the HSA using both synthetic data and real data from ten subjects. The synthetic data includes multiple realizations of four different noise levels and several realizations of typical noise with a 20 % bias field level. The Dice index and Hausdorff distance were used to measure the segmentation accuracy. The indirect evaluation was performed relative to the reference method BET-FAST using synthetic two-dimensional (2D) multimodal magnetic resonance (MR) data with 3 % noise and synthetic EEG (generated for a prescribed source). The source localiza- tion accuracy was determined in terms of localization error and relative error of potential. The experimental results dem- onstrate the efficacy of HSA-BAMS, its robustness to noise and the bias field, and that it provides better segmentation accuracy than the reference method and variants of the HSA. They also show that it leads to a more accurate localization accuracy than the commonly used reference method and sug- gest that it has potential as a surrogate for expert manual segmentation for the EEG source localization problem.
  •  
2.
  • Dobsicek Trefna, Hana, 1979, et al. (författare)
  • Antenna Applicator for Microwave Hyperthermia Treatment of Pediatric Brain Cancer
  • 2014
  • Ingår i: 8th European Conference on Antennas and Propagation, EuCAP 2014, The Hague, The Netherlands 6-11 April 2014. - 9788890701849
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • A novel antenna applicator for microwave hyperthermia allowing treatment of deep brain tumors is proposed. The applicator consists of up to 16 antennas placed around the head in a helmet-like set-up and operates at a frequency range of 430-1000~MHz. The self-grounded bow-tie antennas are housed in a molded plastic enclosure with the shape of a truncated cone. The inner space of the enclosure is filled with distilled water. The antennas are attached to a perimetric water bolus with a thickness of 2 cm and aligned with the head shape. The focusing ability of the applicator was investigated on a homogeneous SAM model and on a model of a 13-year old patient containing a spherical tumor of 2 cm radius. Two different tumor positions were investigated: the right frontal lobe and the central brain. The obtained SAR distributions are favorable, although a relatively high level of energy is also absorbed on the surface of the body. This heating is however not expected to cause problems as it can be cooled by blood perfusion and water bolus. Our results show that focused microwave heating in the brain is feasible and warrants further verification on phantoms.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Dobsicek Trefna, Hana, 1979, et al. (författare)
  • Numerical Evaluation of Clinical Applicator for Microwave Hyperthermia Treatment of Head & Neck Tumors
  • 2013
  • Ingår i: 7th European Conference on Antennas and Propagation.
  • Konferensbidrag (refereegranskat)abstract
    • Design, analysis and evaluation of a novel antenna applicator for microwave hyperthermia. The self-grounded Bow-Tie antenna immersed in cylindrical water bolus serves as an array element. The applicator consists of 12 to 18 elementsarranged in one to three ring set-ups and operates at frequency range between 400 and 1000 MHz.
  •  
9.
  • Dobsicek Trefna, Hana, 1979, et al. (författare)
  • Quality assurance guidelines for superficial hyperthermia clinical trials: I. Clinical requirements
  • 2017
  • Ingår i: International Journal of Hyperthermia. - : Informa UK Limited. - 0265-6736 .- 1464-5157. ; 33:4, s. 471-482
  • Tidskriftsartikel (refereegranskat)abstract
    • Quality assurance guidelines are essential to provide uniform execution of clinical trials and treatment in the application of hyperthermia. This document provides definitions for a good hyperthermia treatment and identifies the clinical conditions where a certain hyperthermia system can or cannot adequately heat the tumour volume. It also provides brief description of the characteristics and performance of the current electromagnetic (radiative and capacitive), ultrasound and infra-red heating techniques. This information helps to select the appropriate heating technique for the specific tumour location and size, and appropriate settings of the water bolus and thermometry. Finally, requirements of staff training and documentation are provided. The guidelines in this document focus on the clinical application and are complemented with a second, more technical quality assurance document providing instructions and procedure to determine essential parameters that describe heating properties of the applicator for superficial hyperthermia. Both sets of guidelines were developed by the ESHO Technical Committee with participation of senior STM members and members of the Atzelsberg Circle.
  •  
10.
  • Qaiser, Mahmood, 1981, et al. (författare)
  • On the Fully Automatic Construction of a Realistic Head Model for EEG Source Localization
  • 2013
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. Osaka, Japan, 3-7 July 2013. - 1557-170X. - 9781457702167 ; , s. 3331-3334
  • Konferensbidrag (refereegranskat)abstract
    • Accurate multi-tissue segmentation of magnetic resonance (MR) images is an essential first step in the construction of a realistic finite element head conductivity model (FEHCM) for electroencephalography (EEG) source localization. All of the segmentation approaches proposed to date for this purpose require manual intervention or correction and are thus laborious, time-consuming, and subjective. In this paper we propose and evaluate a fully automatic method based on a hierarchical segmentation approach (HSA) incorporating Bayesian-based adaptive mean-shift segmentation (BAMS). An evaluation of HSA-BAMS, as well as two reference methods, in terms of both segmentation accuracy and the source localization accuracy of the resulting FEHCM is also presented. The evaluation was performed using (i) synthetic 2D multi-modal MRI head data and synthetic EEG (generated for a prescribed source), and (ii) real 3D T1-weighted MRI head data and real EEG data (with expert determined source localization). Expert manual segmentation served as segmentation ground truth. The results show that HSA-BAMS outperforms the two reference methods and that it can be used as a surrogate for manual segmentation for the construction of a realistic FEHCM for EEG source localization.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy