SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gershan Vesna) "

Sökning: WFRF:(Gershan Vesna)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • de Las Heras Gala, Hugo, et al. (författare)
  • Quality control in cone-beam computed tomography (CBCT): EFOMP-ESTRO-IAEA protocol
  • 2017
  • Rapport (refereegranskat)abstract
    • Quality control of cone-beam computed tomography (CBCT) systems is an essential part of quality assurance to periodically check that quality requirements are met, reduce uncertainties and errors and reduce the likelihood of accidents and incidents. Radiation exposure levels must be measured to ensure that patient doses associated with CBCT examinations are kept as low as reasonably achievable consistent with the required diagnostic information. The main purpose of this document is to present procedures for quality control of CBCT systems used for dental, radiotherapy, interventional radiology and guided surgery applications.
  •  
2.
  • de Las Heras Gala, Hugo, et al. (författare)
  • Quality control in cone-beam computed tomography (CBCT) EFOMP-ESTRO-IAEA protocol (summary report)
  • 2017
  • Ingår i: Physica medica (Testo stampato). - : Elsevier BV. - 1120-1797 .- 1724-191X. ; 39, s. 67-72
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of the guideline presented in this article is to unify the test parameters for image quality evaluation and radiation output in all types of cone-beam computed tomography (CBCT) systems. The applications of CBCT spread over dental and interventional radiology, guided surgery and radiotherapy. The chosen tests provide the means to objectively evaluate the performance and monitor the constancy of the imaging chain. Experience from all involved associations has been collected to achieve a consensus that is rigorous and helpful for the practice. The guideline recommends to assess image quality in terms of uniformity, geometrical precision, voxel density values (or Hounsfield units where available), noise, low contrast resolution and spatial resolution measurements. These tests usually require the use of a phantom and evaluation software. Radiation output can be determined with a kerma-area product meter attached to the tube case. Alternatively, a solid state dosimeter attached to the flat panel and a simple geometric relationship can be used to calculate the dose to the isocentre. Summary tables including action levels and recommended frequencies for each test, as well as relevant references, are provided. If the radiation output or image quality deviates from expected values, or exceeds documented action levels for a given system, a more in depth system analysis (using conventional tests) and corrective maintenance work may be required.
  •  
3.
  • Gennaro, Gisella, et al. (författare)
  • Quality Controls in Digital Mammography protocol of the EFOMP Mammo Working group
  • 2018
  • Ingår i: Physica Medica. - : Elsevier BV. - 1120-1797. ; 48, s. 55-64
  • Tidskriftsartikel (refereegranskat)abstract
    • This article aims to present the protocol on Quality Controls in Digital Mammography published online in 2015 by the European Federation of Organisations for Medical Physics (EFOMP) which was developed by a Task Force under the Mammo Working Group. The main objective of this protocol was to define a minimum set of easily implemented quality control tests on digital mammography systems that can be used to assure the performance of a system within a set and acceptable range. Detailed step-by-step instructions have been provided, limiting as much as possible any misinterpretations or variations by the person performing. It is intended that these tests be implemented as part of the daily routine of medical physicists and system users throughout Europe in a harmonised way so allowing results to be compared. In this paper the main characteristics of the protocol are illustrated, including examples, together with a brief summary of the contents of each chapter. Finally, instructions for the download of the full protocol and of the related software tools are provided.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy