SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Giannitsis E.) "

Sökning: WFRF:(Giannitsis E.)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  • Saenger, A. K., et al. (författare)
  • Multicenter analytical evaluation of a high-sensitivity troponin T assay
  • 2011
  • Ingår i: Clinica Chimica Acta. - : Elsevier BV. - 0009-8981 .- 1873-3492. ; 412:9-10, s. 748-754
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: High-sensitivity cardiac troponin assays are being introduced clinically for earlier diagnosis of acute myocardial infarction (AMI). We evaluated the analytical performance of a high-sensitivity cardiac troponin T assay (hscTnT. Roche Diagnostics) in a multicenter, international trial. Methods: Three US and 5 European sites evaluated hscTnT on the Modular (R) Analytics E170, cobas (R) 6000, Elecsys 2010, and cobas (R) e 411. Precision, accuracy, reportable range, an inter-laboratory comparison trial, and the 99th percentile of a reference population were assessed. Results: Total imprecision (CVs) were 4.6-36.8% between 3.4 and 10.3 ng/L hscTnT. Assay linearity was up to 10,000 ng/L and the limit of blank and detection were 3 and 5 ng/L, respectively. The 99th percentile reference limit was 14.2 ng/L (n = 533). No significant differences between specimen types, assay incubation time, or reagent lots existed. A substantial positive bias (76%) exists between the 4th generation and hscTnT assays at the low end of the measuring range (< 50 ng/L). hscTnT serum pool concentrations were within 2SD limits of the mean of means in the comparison trial, indicating comparable results across multiple platforms and laboratories. Conclusion: The Roche hscTnT assay conforms to guideline precision requirements and will likely identify additional patients with myocardial injury suspicious for AMI.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Boeddinghaus, Jasper, et al. (författare)
  • Impact of age on the performance of the ESC 0/1h-algorithms for early diagnosis of myocardial infarction
  • 2018
  • Ingår i: European Heart Journal. - : OXFORD UNIV PRESS. - 0195-668X .- 1522-9645. ; 39:42, s. 3780-3794
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims We aimed to evaluate the impact of age on the performance of the European Society of Cardiology (ESC) 0/1h-algorithms and to derive and externally validate alternative cut-offs specific to older patients. Methods and results We prospectively enrolled patients presenting to the emergency department (ED) with symptoms suggestive of and results acute myocardial infarction in three large diagnostic studies. Final diagnoses were adjudicated by two independent cardiologists. High-sensitivity cardiac troponin (hs-cTn) T and I concentrations were measured at presentation and after 1 h. Patients were stratified according to age [<55 years (young), >= 55 to <70 years (middle-age), >= 70 years (old)]. Rule-out safety of the ESC hs-cTnT 0/1h-algorithm was very high in all age-strata: sensitivity 100% [95% confidence interval (95% CI) 94.9-100] in young, 99.3% (95% CI 96.0-99.9) in middle-age, and 99.3% (95% CI 97.599.8) in old patients. Accuracy of rule-in decreased with age: specificity 97.0% (95% CI 95.8-97.9) in young, 96.1% (95% CI 94.5-97.2) in middle-age, and 92.7% (95% CI 90.7-94.3) in older patients. Triage efficacy decreased with increasing age (young 93%, middle-age 80%, old 55%, P <0.001). Similar results were found for the ESC hs-cTnT 0/1h-algorithm. Alternative, slightly higher cut-off concentrations optimized for older patients maintained very high safety of rule-out, increased specificity of rule-in (P< 0.01), reduced overall efficacy for hs-cTnT (P <0.01), while maintaining efficacy for hs-cTnl. Findings were confirmed in two validation cohorts (n = 2767). Conclusion While safety of the ESC 0/1h-algorithms remained very high, increasing age significantly reduced overall efficacy and the accuracy of rule-in. Alternative slightly higher cut-off concentrations may be considered for older patients, particularly if using hs-cTnl.
  •  