SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Giclas Patricia C.) "

Sökning: WFRF:(Giclas Patricia C.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bergseth, Grethe, et al. (författare)
  • An international serum standard for application in assays to detect human complement activation products
  • 2013
  • Ingår i: Molecular Immunology. - : Elsevier BV. - 0161-5890 .- 1872-9142. ; 56:3 SI, s. 232-239
  • Forskningsöversikt (refereegranskat)abstract
    • The importance of the complement system in clinical medicine has become evident during the last decades and complement therapeutics has now reached the clinic. Thus, there is an increased interest in and need for assays to evaluate complement activity and dysfunction. Pathologically increased complement activation can indirectly be evaluated by quantification of complement components, but in order to exactly measure such activation, assays for quantification of products formed during activation are required. Progress in this field is hampered by lack of standardization. Therefore, members of the International Complement Standardization Committee, a joint initiative of the International Complement Society and the International Union of Immunological Societies (IUIS), prepared a defined standard for application in assays for complement activation products. We here report on the production and properties of this International Complement Standard #2 (ICS#2). ICS#2 was made from a pool of sera from healthy blood donors (ICS#1) that was activated with a combination of heat-aggregated IgG and zymosan, and subsequently stabilized by adding EDTA and nafamostat mesylate. The protocol was optimized to make the standard applicable in the following activation product assays: C1rs-C1-inhibitor complexes, C4a, C4bc, C4d, Bb, C3bBbP, C3a, C3bc, C3dg, C5a and the soluble terminal C5b-9 complement complex (SC5b-9, TCC). ICS#2 was defined as containing 1000 complement activation units (CAU)/mL for all activation products measured. All activation products were stable after 10 times thawing and freezing and most of the activation products were stable during storage at 4 degrees C for up to 21 days. ICS#2 was produced large-scale and is considered a valuable tool for standardization, calibration and reference control for complement activation assays, providing the necessary prerequisite for quality assessments between complement laboratories. 
  •  
2.
  • Paixao-Cavalcante, Danielle, et al. (författare)
  • Sensitive and specific assays for C3 nephritic factors clarify mechanisms underlying complement dysregulation
  • 2012
  • Ingår i: Kidney International. - : Elsevier BV. - 1523-1755 .- 0085-2538. ; 82:10, s. 1084-1092
  • Tidskriftsartikel (refereegranskat)abstract
    • C3 nephritic factors are autoantibodies that prolong the half-life or prevent regulation of the alternative pathway C3 convertase, resulting in uncontrolled complement activation. They are strongly associated with renal disease but their role in pathogenesis remains controversial. Here we optimized and compared a panel of assays to identify and interrogate nephritic factor activities. Of 101 patients with histologic or clinically evident disease, 48 were positive in some or all assays. In the presence of properdin, binding of autoantibody was detected in 39 samples and convertase stabilization was detected in 36. Forty-two of 48 nephritic factors tested prevented convertase decay by factor H, and most of these by decay accelerating factor (28) and complement receptor 1 (34). Representative properdin-independent nephritic factors had no effect on C5 cleavage and terminal pathway activity, while properdin-dependent nephritic factors enhanced activity. Biacore analysis of four purified IgG samples confirmed resistance to decay and showed that properdin-independent nephritic factors increased convertase half-life over 50-fold, whereas properdin-dependent nephritic factors increased the half-life 10- to 20-fold and also increased activity of the C3 convertase up to 10-fold. Thus, our study provides a rational approach to detect and characterize nephritic factors in patients. Kidney International (2012) 82, 1084-1092; doi:10.1038/ki.2012.250; published online 1 August 2012
  •  
3.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy