SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Glatting Gerhard) "

Sökning: WFRF:(Glatting Gerhard)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Gear, Jonathan I., et al. (författare)
  • EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations
  • 2018
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 45:13, s. 2456-2474
  • Tidskriftsartikel (refereegranskat)abstract
    • A framework is proposed for modelling the uncertainty in the measurement processes constituting the dosimetry chain that are involved in internal absorbed dose calculations. The starting point is the basic model for absorbed dose in a site of interest as the product of the cumulated activity and a dose factor. In turn, the cumulated activity is given by the area under a time–activity curve derived from a time sequence of activity values. Each activity value is obtained in terms of a count rate, a calibration factor and a recovery coefficient (a correction for partial volume effects). The method to determine the recovery coefficient and the dose factor, both of which are dependent on the size of the volume of interest (VOI), are described. Consideration is given to propagating estimates of the quantities concerned and their associated uncertainties through the dosimetry chain to obtain an estimate of mean absorbed dose in the VOI and its associated uncertainty. This approach is demonstrated in a clinical example.
  •  
2.
  • Hindorf, Cecilia, et al. (författare)
  • EANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
  • 2010
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 37:6, s. 1238-1250
  • Tidskriftsartikel (refereegranskat)abstract
    • The level of administered activity in radionuclide therapy is often limited by haematological toxicity resulting from the absorbed dose delivered to the bone marrow. The purpose of these EANM guidelines is to provide advice to scientists and clinicians on data acquisition and data analysis related to bone-marrow and whole-body dosimetry. The guidelines are divided into sections "Data acquisition" and "Data analysis". The Data acquisition section provides advice on the measurements required for accurate dosimetry including blood samples, quantitative imaging and/or whole-body measurements with a single probe. Issues specific to given radiopharmaceuticals are considered. The Data analysis section provides advice on the calculation of absorbed doses to the whole body and the bone marrow. The total absorbed dose to the bone marrow consists of contributions from activity in the bone marrow itself (self-absorbed dose) and the cross-absorbed dose to the bone marrow from activity in bone, larger organs and the remainder of the body. As radionuclide therapy enters an era where patient-specific dosimetry is used to guide treatments, accurate bone-marrow and whole-body dosimetry will become an essential element of treatment planning. We hope that these guidelines will provide a basis for the optimization and standardization of the treatment of cancer with radiopharmaceuticals, which will facilitate single- and multi-centre radionuclide therapy studies.
  •  
3.
  • Ivashchenko, Oleksandra V., et al. (författare)
  • Time-Activity data fitting in molecular Radiotherapy : Methodology and pitfalls
  • 2024
  • Ingår i: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 117
  • Tidskriftsartikel (refereegranskat)abstract
    • Absorbed radiation doses are essential in assessing the effects, e.g. safety and efficacy, of radiopharmaceutical therapy (RPT). Patient-specific absorbed dose calculations in the target or the organ at risk require multiple inputs. These include the number of disintegrations in the organ, i.e. the time-integrated activities (TIAs) of the organs, as well as other parameters describing the process of radiation energy deposition in the target tissue (i.e. mean energy per disintegration, radiation dose constants, etc). TIAs are then estimated by incorporating the area under the radiopharmaceutical's time-activity curve (TAC), which can be obtained by quantitative measurements of the biokinetics in the patient (typically based on imaging data such as planar scintigraphy, SPECT/CT, PET/CT, or blood and urine samples). The process of TAC determination/calculation for RPT generally depends on the user, e.g., the chosen number and schedule of measured time points, the selection of the fit function, the error model for the data and the fit algorithm. These decisions can strongly affect the final TIA values and thus the accuracy of calculated absorbed doses. Despite the high clinical importance of the TIA values, there is currently no consensus on processing time-activity data or even a clear understanding of the influence of uncertainties and variations in personalised RPT dosimetry related to user-dependent TAC calculation. As a first step towards minimising site-dependent variability in RPT dosimetry, this work provides an overview of quality assurance and uncertainty management considerations of the TIA estimation.
  •  
4.
  •  
5.
  • Vasić, Valentina, et al. (författare)
  • A PBPK model for PRRT with [177Lu]Lu-DOTA-TATE : Comparison of model implementations in SAAM II and MATLAB/SimBiology
  • 2024
  • Ingår i: Physica Medica. - 1120-1797. ; 119
  • Tidskriftsartikel (refereegranskat)abstract
    • Physiologically based pharmacokinetic (PBPK) models offer the ability to simulate and predict the biodistribution of radiopharmaceuticals and have the potential to enable individualised treatment planning in molecular radiotherapy. The objective of this study was to develop and implement a whole-body compartmental PBPK model for peptide receptor radionuclide therapy (PRRT) with [177Lu]Lu-DOTA-TATE in SimBiology to allow for more complex analyses. The correctness of the model implementation was ensured by comparing its outputs, such as the time-integrated activity (TIA), with those of a PBPK model implemented in SAAM II software. Methods: A combined PBPK model for [68Ga]Ga-DOTA-TATE and [177Lu]Lu-DOTA-TATE was developed and implemented in both SAAM II and SimBiology. A retrospective analysis of 12 patients with metastatic neuroendocrine tumours (NETs) was conducted. First, time-activity curves (TACs) and TIAs from the two software were calculated and compared for identical parameter values. Second, pharmacokinetic parameters were fitted to activity concentrations, analysed and compared. Results: The PBPK model implemented in SimBiology produced TIA results comparable to those generated by the model implemented in SAAM II, with a relative deviation of less than 0.5% when using the same input parameters. The relative deviation of the fitted TIAs was less than 5% when model parameter values were fitted to the measured activity concentrations. Conclusion: The proposed PBPK model implemented in SimBiology can be used for dosimetry in radioligand therapy and TIA prediction. Its outputs are similar to those generated by the PBPK model implemented in SAAM II, confirming the correctness of the model implementation in SimBiology.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy