SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gleisner M.) "

Sökning: WFRF:(Gleisner M.)

  • Resultat 1-10 av 22
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Tran-Gia, Johannes, et al. (författare)
  • On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration : a European multi-centre evaluation
  • 2023
  • Ingår i: EJNMMI Physics. - 2197-7364. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods: Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results: As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion: This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.
  •  
2.
  •  
3.
  •  
4.
  • Gleisner, M., et al. (författare)
  • Comparison of sulfide oxidation in unweathered pyretic mine tailings
  • 2003
  • Ingår i: Proc. ICARD 2003, 6th Int. Conf. on Acid Rock Drainage, Cairns, Australia, July 14 – 17, 2003. ; , s. 1027-1030
  • Konferensbidrag (refereegranskat)abstract
    • The study focuses on sulfide oxidation processes in unweathered pyrite-rich mine tailings from a soil-covered impoundment in northern Sweden. To simulate the oxygen-limited conditions in water saturated tailings two long-term column experiments were performed. Results are presented for the first 11 months of the experiments at room temperature. The tailings used in the experiments were of two different grain sizes (one coarse grained, in the range 0.02 - 0.6 mm with a grain surface area of 1.86 m2 g-1, and one fine-grained, in the range 0.0015 - 0.06 mm with a grain surface area of 10.00 m2 g-1) and with slightly different mineralogical composition. The S:Fe molar ratio in the leachates (1.0 - 1.5) indicates either that pyrrhotite is the main iron sulfide undergoing oxidation in our experiments, or, alternatively that the S:Fe molar ratio in the leachate is determined by pyrite weathering in conjunction with other processes releasing iron or immobilising sulfate. However, speciation modelling of the leachates indicates that ferrihydrite was close to saturation, suggesting that a ferric oxyhydroxide may have dissolved/ precipitated during the experimental period, thereby affecting the S:Fe molar ratio. Pyrite oxidation rates obtained from the two column experiments during ‘steady-state’ were 2.25 × 10-13 and 8.45 × 10-14 mol m-2 s-1 in the coarse and fine tailings, respectively. Pyrrhotite oxidation rates, as an alternative, were 2.31 × 10-12 and 1.24 × 10-11 mol m-2 s-1 in the coarse and fine tailings, respectively. Natural microbial activity was confirmed in both the tailings and the leachates; therefore, the obtained oxidation rates are not strictly abiotic. It is thus concluded, based on the experimental results, that tailing heterogeneity will result in zones with different oxidation rates, related to their physical and chemical properties.
  •  
5.
  • Sjögreen Gleisner, Katarina, et al. (författare)
  • EANM dosimetry committee recommendations for dosimetry of 177Lu-labelled somatostatin-receptor- and PSMA-targeting ligands
  • 2022
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 49, s. 1778-1809
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of the EANM Dosimetry Committee is to provide recommendations and guidance to scientists and clinicians on patient-specific dosimetry. Radiopharmaceuticals labelled with lutetium-177 (177Lu) are increasingly used for therapeutic applications, in particular for the treatment of metastatic neuroendocrine tumours using ligands for somatostatin receptors and prostate adenocarcinoma with small-molecule PSMA-targeting ligands. This paper provides an overview of reported dosimetry data for these therapies and summarises current knowledge about radiation-induced side effects on normal tissues and dose-effect relationships for tumours. Dosimetry methods and data are summarised for kidneys, bone marrow, salivary glands, lacrimal glands, pituitary glands, tumours, and the skin in case of radiopharmaceutical extravasation. Where applicable, taking into account the present status of the field and recent evidence in the literature, guidance is provided. The purpose of these recommendations is to encourage the practice of patient-specific dosimetry in therapy with 177Lu-labelled compounds. The proposed methods should be within the scope of centres offering therapy with 177Lu-labelled ligands for somatostatin receptors or small-molecule PSMA.
  •  
6.
  • Torres, A, et al. (författare)
  • Haptoglobin Induces a Specific Proteomic Profile and a Mature-Associated Phenotype on Primary Human Monocyte-Derived Dendritic Cells
  • 2022
  • Ingår i: International journal of molecular sciences. - : MDPI AG. - 1422-0067. ; 23:13
  • Tidskriftsartikel (refereegranskat)abstract
    • Damage-associated molecular patterns (DAMPs) play a critical role in dendritic cells (DCs) ability to trigger a specific and efficient adaptive immune response for different physiological and pathological scenarios. We have previously identified constitutive DAMPs (HMGB1 and Calreticulin) as well as new putative inducible DAMPs such as Haptoglobin (HP), from a therapeutically used heat shock-conditioned melanoma cell lysate (called TRIMEL). Remarkably, HP was shown to be the most abundant protein in the proteomic profile of heat shock-conditioned TRIMEL samples. However, its relative contribution to the observed DCs phenotype has not been fully elucidated. Human DCs were generated from monocytes isolated from PBMC of melanoma patients and healthy donors. DC lineage was induced with rhIL-4 and rhGM-CSF. After additional stimulation with HP, the proteome of these HP-stimulated cells was characterized. In addition, DCs were phenotypically characterized by flow cytometry for canonical maturation markers and cytokine production. Finally, in vitro transmigration capacity was assessed using Transwell plates. Our results showed that the stimulation with HP was associated with the presence of exclusive and higher relative abundance of specific immune-; energy production-; lipid biosynthesis-; and DAMPs-related proteins. Importantly, HP stimulation enhanced the expression of specific DC maturation markers and pro-inflammatory and Th1-associated cytokines, and an in vitro transmigration of primary human DCs. Taken together, these data suggest that HP can be considered as a new inducible DAMP with an important role in in vitro DC activation for cancer immunotherapy.
  •  
7.
  • Tran-Gia, Johannes, et al. (författare)
  • A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project
  • 2021
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the radiopharmaceutical taken up by an organ/lesion over time. As uncertainties propagate along each of the subsequent steps (integration of the time–activity curve, absorbed dose calculation), establishing a reliable activity quantification is essential. The MRTDosimetry project was a European initiative to bring together expertise in metrology and nuclear medicine research, with one main goal of standardizing quantitative 177Lu SPECT/CT imaging based on a calibration protocol developed and tested in a multicentre inter-comparison. This study presents the setup and results of this comparison exercise. Methods: The inter-comparison included nine SPECT/CT systems. Each site performed a set of three measurements with the same setup (system, acquisition and reconstruction): (1) Determination of an image calibration for conversion from counts to activity concentration (large cylinder phantom), (2) determination of recovery coefficients for partial volume correction (IEC NEMA PET body phantom with sphere inserts), (3) validation of the established quantitative imaging setup using a 3D printed two-organ phantom (ICRP110-based kidney and spleen). In contrast to previous efforts, traceability of the activity measurement was required for each participant, and all participants were asked to calculate uncertainties for their SPECT-based activities. Results: Similar combinations of imaging system and reconstruction lead to similar image calibration factors. The activity ratio results of the anthropomorphic phantom validation demonstrate significant harmonization of quantitative imaging performance between the sites with all sites falling within one standard deviation of the mean values for all inserts. Activity recovery was underestimated for total kidney, spleen, and kidney cortex, while it was overestimated for the medulla. Conclusion: This international comparison exercise demonstrates that harmonization of quantitative SPECT/CT is feasible when following very specific instructions of a dedicated calibration protocol, as developed within the MRTDosimetry project. While quantitative imaging performance demonstrates significant harmonization, an over- and underestimation of the activity recovery highlights the limitations of any partial volume correction in the presence of spill-in and spill-out between two adjacent volumes of interests.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 22
Typ av publikation
tidskriftsartikel (15)
konferensbidrag (3)
rapport (2)
forskningsöversikt (2)
Typ av innehåll
refereegranskat (19)
övrigt vetenskapligt/konstnärligt (2)
populärvet., debatt m.m. (1)
Författare/redaktör
Gleisner, M. (6)
Bernhardt, Peter, 19 ... (4)
Sjögreen Gleisner, K ... (4)
Strigari, L. (3)
Tittarelli, A (3)
Ljungberg, M (3)
visa fler...
Chiesa, C. (3)
Ljungberg, Michael (2)
Konijnenberg, M. (2)
Svensson, Johanna (2)
Lassmann, M (2)
Lassmann, Michael (2)
Chouin, Nicolas (2)
Bardies, M. (2)
Navarro, G. (1)
Vidal, M. (1)
Cremonesi, M. (1)
Wängberg, Bo, 1953 (1)
Rydén, Tobias (1)
Achour, A (1)
Torres, A (1)
Alsberg, T (1)
Alsberg, (1)
Visser, E. (1)
Strand, Sven-Erik (1)
Ohlsson, T. (1)
Forssell-Aronsson, E ... (1)
Darudi, Ahmad (1)
Kärsrud, (1)
Broms, S. (1)
Kärsrud, A (1)
Andersen, Torben (1)
Owner-Petersen, Mett ... (1)
Gilmozzi, Roberto (1)
Tennvall, Jan (1)
Malmström, Maria E. (1)
Zubarev, RA (1)
Sjögren, Hans Olov (1)
Gjertsson, P. (1)
Bergqvist, A (1)
Tennvall, J (1)
Chernobrovkin, A. (1)
Isaksson, M (1)
Chen, Jianing (1)
Trask, Catherine M. (1)
Chouin, N. (1)
Sundlöv, Anna (1)
Thejll, Peter (1)
Ljunggren, Kaj (1)
Garkavij, Michael (1)
visa färre...
Lärosäte
Lunds universitet (10)
Göteborgs universitet (4)
Karolinska Institutet (4)
Uppsala universitet (3)
Kungliga Tekniska Högskolan (2)
Stockholms universitet (2)
Språk
Engelska (20)
Svenska (2)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (10)
Medicin och hälsovetenskap (10)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy