SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gormsen Lars C) "

Sökning: WFRF:(Gormsen Lars C)

  • Resultat 1-8 av 8
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Christensen, Nana L, et al. (författare)
  • Detection and correction of patient motion in dynamic 15O-water PET MPI.
  • 2023
  • Ingår i: Journal of Nuclear Cardiology. - : Elsevier. - 1071-3581 .- 1532-6551. ; 30:6, s. 2736-2749
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Patient motion constitutes a limitation to 15O-water cardiac PET imaging. We examined the ability of image readers to detect and correct patient motion using simulated motion data and clinical patient scans.METHODS: Simulated data consisting of 16 motions applied to 10 motion-free scans were motion corrected using two approaches, pre-analysis and post-analysis for motion identification. Both approaches employed a manual frame-by-frame correction method. In addition, a clinical cohort was analyzed for assessment of prevalence and effect of motion and motion correction.RESULTS: Motion correction was performed on 94% (pre-analysis) and 64% (post-analysis) of the scans. Large motion artifacts were corrected in 91% (pre-analysis) and 74% (post-analysis) of scans. Artifacts in MBF were reduced in 56% (pre-analysis) and 58% (post-analysis) of the scans. The prevalence of motion in the clinical patient cohort (n = 762) was 10%. Motion correction altered exam interpretation in only 10 (1.3%) clinical patient exams.CONCLUSION: Frame-by-frame motion correction after visual inspection is useful in reducing motion artifacts in cardiac 15O-water PET. Reviewing the initial results (parametric images and polar maps) as part of the motion correction process, reduced erroneous corrections in motion-free scans. In a large clinical cohort, the impact of motion correction was limited to few patients.
  •  
2.
  • Hoff, Camilla Molich, et al. (författare)
  • Quantitative and qualitative comparison of Rubidium-82 and Oxygen-15 water cardiac PET.
  • 2024
  • Ingår i: Journal of Nuclear Cardiology. - 1071-3581 .- 1532-6551. ; , s. 101796-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD).METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed.RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min).CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.
  •  
3.
  • Nielsen, Roni, et al. (författare)
  • Cardiovascular Effects of Treatment With the Ketone Body 3-Hydroxybutyrate in Chronic Heart Failure Patients
  • 2019
  • Ingår i: Circulation. - : LIPPINCOTT WILLIAMS & WILKINS. - 0009-7322 .- 1524-4539. ; 139:18, s. 2129-2141
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Myocardial utilization of 3-hydroxybutyrate (3-OHB) is increased in patients with heart failure and reduced ejection fraction (HFrEF). However, the cardiovascular effects of increased circulating plasma-3-OHB levels in these patients are unknown. Consequently, the authors' aim was to modulate circulating 3-OHB levels in HFrEF patients and evaluate: (1) changes in cardiac output (CO); (2) a potential doseresponse relationship between 3-OHB levels and CO; (3) the impact on myocardial external energy efficiency (MEE) and oxygen consumption (MVO 2); and (4) whether the cardiovascular response differed between HFrEF patients and age-matched volunteers.METHODS: Study 1: 16 chronic HFrEF patients (left ventricular ejection fraction: 37 +/- 3%) were randomized in a crossover design to 3-hour of 3-OHB or placebo infusion. Patients were monitored invasively with a Swan-Ganz catheter and with echocardiography. Study 2: In a doseresponse study, 8 HFrEF patients were examined at increasing 3-OHB infusion rates. Study 3 to 4: 10 HFrEF patients and 10 age-matched volunteers were randomized in a crossover design to 3-hour 3-OHB or placebo infusion. MEE and MVO 2 were evaluated using 11C-acetate positron emission tomography.RESULTS: 3-OHB infusion increased circulating levels of plasma 3-OHB from 0.4 +/- 0.3 to 3.3 +/- 0.4 mM (P< 0.001). CO rose by 2.0 +/- 0.2 L/min (P< 0.001) because of an increase in stroke volume of 20 +/- 2 mL (P< 0.001) and heart rate of 7 +/- 2 beats per minute (bpm) (P< 0.001). Left ventricular ejection fraction increased 8 +/- 1% (P< 0.001) numerically. There was a dose-response relationship with a significant CO increase of 0.3 L/min already at plasma-3-OHB levels of 0.7 mM (P< 0.001). 3-OHB increased MVO 2 without altering MEE. The response to 3-OHB infusion in terms of MEE and CO did not differ between HFrEF patents and age-matched volunteers.CONCLUSIONS: 3-OHB has beneficial hemodynamic effects in HFrEF patients without impairing MEE. These beneficial effects are detectable in the physiological concentration range of circulating 3-OHB levels. The hemodynamic effects of 3-OHB were observed in both HFrEF patients and age-matched volunteers. 3-OHB may potentially constitute a novel treatment principle in HFrEF patients.
  •  
4.
  • Di Carli, Marcelo F, et al. (författare)
  • Rationale and design of the RAPID-WATER-FLOW trial : Radiolabeled perfusion to identify coronary artery disease using water to evaluate responses of myocardial FLOW.
  • 2024
  • Ingår i: Journal of Nuclear Cardiology. - 1071-3581 .- 1532-6551. ; 31, s. 101779-
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: The objective of this study was to determine the diagnostic performance of 15O-water positron emission tomography (PET) myocardial perfusion imaging to detect coronary artery disease (CAD) using the truth-standard of invasive coronary angiography (ICA) with fractional flow reserve (FFR) or instantaneous wave-Free Ratio (iFR) or coronary computed tomography angiogram (CCTA).BACKGROUND: 15O-water has a very high first-pass extraction that allows accurate quantification of myocardial blood flow and detection of flow-limiting CAD. However, the need for an on-site cyclotron and lack of automated production at the point of care and relatively complex image analysis protocol has limited its clinical use to date.METHODS: The RAPID WATER FLOW study is an open-label, multicenter, prospective investigation of the accuracy of 15O-water PET to detect obstructive angiographic and physiologically significant stenosis in patients with suspected CAD. The study will include the use of an automated system for producing, dosing, and injecting 15O-water and enrolling approximately 215 individuals with suspected CAD at approximately 10 study sites in North America and Europe. The primary endpoint of the study is the diagnostic sensitivity and specificity of the 15O-water PET study using the truth-standard of ICA with FFR or iFR to determine flow-limiting stenosis, or CCTA to rule out CAD and incorporating a quantitative analytic platform developed for the 15O-water PET acquisitions. Sensitivity and specificity are to be considered positive if the lower bound of the 95% confidence interval is superior to the threshold of 60% for both, consistent with prior registration studies. Subgroup analyses include assessments of diagnostic sensitivity, specificity, and accuracy in female, obese, and diabetic individuals, as well as in those with multivessel disease. All enrolled individuals will be followed for adverse and serious adverse events for up to 32 hours after the index PET scan. The study will have >90% power (one-sided test, α = 0.025) to test the hypothesis that sensitivity and specificity of 15O-water PET are both >60%.CONCLUSIONS: The RAPID WATER FLOW study is a prospective, multicenter study to determine the diagnostic sensitivity and specificity of 15O-water PET as compared to ICA with FFR/iFR or CCTA. This study will introduce several novel aspects to imaging registration studies, including a more relevant truth standard incorporating invasive physiologic indexes, coronary CTA to qualify normal individuals for eligibility, and a more quantitative approach to image analysis than has been done in prior pivotal studies.CLINICAL TRIAL REGISTRATION INFORMATION: Clinical-Trials.gov (#NCT05134012).
  •  
5.
  •  
6.
  • Pedersen, Mette A., et al. (författare)
  • Focal skeletal FDG uptake indicates poor prognosis in cHL regardless of extent and first-line chemotherapy
  • 2019
  • Ingår i: British Journal of Haematology. - : WILEY. - 0007-1048 .- 1365-2141. ; 186:3, s. 431-439
  • Tidskriftsartikel (refereegranskat)abstract
    • F-18-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) is used for staging classical Hodgkin lymphoma (cHL) with high sensitivity for skeletal involvement. However, it is unclear whether a single bone lesion carries the same adverse prognosis as multifocal lesions and if this is affected by type of chemotherapy [ABVD (adriamycin, bleomycin, vincristine, dacarbazine) versus BEACOPP (bleomycin, etoposide, adriamycin, cyclophosphamide, vincristine, procarbazine, prednisone)]. We reviewed the clinico-pathological and outcome data from 209 patients with newly diagnosed cHL staged by FDG-PET/CT. Patterns of skeletal/bone marrow uptake (BMU) were divided into 'low' and 'high' diffuse BMU (i.e. without focal lesions), and unifocal or multifocal lesions. Additional separate survival analysis was performed, taking type of chemotherapy into account. Forty patients (19 center dot 2%) had skeletal lesions (20 unifocal, 20 multifocal). The 3-year progression-free-survival (PFS) was 80% for patients with 'low BMU', 87% for 'high BMU', 69% for 'unifocal' and 51% for 'multifocal' lesions; median follow-up was 38 months. The presence of bone lesions, both uni- and multifocal, was associated with significantly inferior PFS (log rank P = 0 center dot 0001), independent of chemotherapy type. Thus, increased diffuse BMU should not be considered as a risk factor in cHL, whereas unifocal or multifocal bone lesions should be regarded as important predictors of adverse outcome, irrespective of the chemotherapy regimen used.
  •  
7.
  • Søndergaard, Esben, et al. (författare)
  • SGLT2 inhibition reduces myocardial oxygen consumption
  • 2022
  • Ingår i: Metabolism Open. - : Elsevier. - 2589-9368. ; 15
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS/HYPOTHESIS: SGLT2 inhibition is associated with a reduced risk of cardiac disease that is still largely unexplained. According to one hypothesis, improved myocardial energetics may explain the cardioprotective effects of SGLT2i. However, recent mechanistic studies that have addressed this question have lacked the power to detect discrete but still clinically significant effects.METHODS: We pooled data from two recent randomized clinical trials and performed a meta-analysis to determine the effect of SGLT2 inhibition on myocardial oxygen consumption and myocardial external efficiency measured by positron emission tomography.RESULTS: SGLT2 inhibition reduced myocardial oxygen consumption (-1.06 [95%CI: 0.22-1.89] mL/100 g/min (n = 59, p = 0.01)), but did not affect myocardial external efficiency (2.22 [95%CI: 0.66-5.11] % (n = 59, p = 0.13)).CONCLUSIONS: /interpretation: SGLT2 inhibition reduces myocardial oxygen consumption at rest, which may contribute to the drugs' cardioprotective effects.
  •  
8.
  • Westra, Jelmer, et al. (författare)
  • Coronary Artery Stenosis Evaluation by Angiography-Derived FFR Validation by Positron Emission Tomography and Invasive Thermodilution
  • 2023
  • Ingår i: JACC Cardiovascular Imaging. - : ELSEVIER SCIENCE INC. - 1936-878X .- 1876-7591. ; 16:10, s. 1321-1331
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis. OBJECTIVES The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard. METHODS This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (>= 50% diameter stenosis in >= 1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score >= 4 in >= 2 adjacent segments).RESULTS A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis. CONCLUSIONS With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717) (J Am Coll Cardiol Img 2023;16:1321-1331) (c) 2023 by the American College of Cardiology Foundation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-8 av 8

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy