SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Granja D) "

Sökning: WFRF:(Granja D)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Granja, C. D. S., et al. (författare)
  • A quartz crystal resonator for cellular phenotyping
  • 2020
  • Ingår i: Biosensors and Bioelectronics: X. - : Elsevier Ltd. - 2590-1370. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Cell therapy manufacturing is limited by lack of online tools capable of realtime in-process monitoring, particularly of simultaneous changes in multiple orthogonal (mutually independent) parameters. Here, we studied changes in CD36 expression, number density and size (area) of erythroblasts through different stages of erythropoiesis in vitro using a quartz crystal resonator (QCR), integrated with a microscope, and flow cytometry in parallel. An analytical model was developed extending the Kanazawa-Gordon theory. Based on this model, independent correlations were established between changes in each QCR parameter, dissipation (ΔΓ) and resonance frequency (−Δf0), and CD36 expression (from flow cytometry) and cell area (from microscope). The correlation functions were used to derive an acoustic signature (−ΔΓ/Δf0) of the differentiation process that uniquely mapped the relative changes in CD36 expression and late-stage enucleation-related deviations. A method to quantify relative changes in cell area purely from the acoustic parameters was also proposed. This work demonstrated for the first time the potential of an electromechanical tool for online monitoring of concurrently varying orthogonal phenotypic parameters in cell therapy manufacturing.
  •  
3.
  • Jones, Christina, et al. (författare)
  • Intensive care diaries reduce new onset post traumatic stress disorder following critical illness : a randomised, controlled trial
  • 2010
  • Ingår i: Critical Care. - : BioMed Central. - 1364-8535 .- 1466-609X. ; 14:5
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Patients recovering from critical illness have been shown to be at risk of developing Post Traumatic Stress disorder (PTSD). This study was to evaluate whether a prospectively collected diary of a patient's intensive care unit (ICU) stay when used during convalescence following critical illness will reduce the development of new onset PTSD.METHODS: Intensive care patients with an ICU stay of more than 72 hours were recruited to a randomised controlled trial examining the effect of a diary outlining the details of the patients ICU stay on the development of acute PTSD. The intervention patients received their ICU diary at 1 month following critical care discharge and the final assessment of the development of acute PTSD was made at 3 months.RESULTS: 352 patients were randomised to the study at 1 month. The incidence of new cases of PTSD was reduced in the intervention group compared to the control patients (5% versus 13%, P = 0.02).CONCLUSIONS: The provision of an ICU diary is effective in aiding psychological recovery and reducing the incidence of new PTSD.
  •  
4.
  •  
5.
  • Kozyrev, A., et al. (författare)
  • A comparative study of LaBr3(Ce3+) and CeBr3 based gamma-ray spectrometers for planetary remote sensing applications
  • 2016
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 87:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The recent availability of large volume cerium bromide crystals raises the possibility of substantially improving gamma-ray spectrometer limiting flux sensitivities over current systems based on the lanthanum tri-halides, e.g., lanthanum bromide and lanthanum chloride, especially for remote sensing, low-level counting applications or any type of measurement characterized by poor signal to noise ratios. The Russian Space Research Institute has developed and manufactured a highly sensitive gamma-ray spectrometer for remote sensing observations of the planet Mercury from the Mercury Polar Orbiter (MPO), which forms part of ESA’s BepiColombo mission. The Flight Model (FM) gamma-ray spectrometer is based on a 3-in. single crystal of LaBr3(Ce3+) produced in a separate crystal development programme specifically for this mission. During the spectrometers development, manufacturing, and qualification phases, large crystals of CeBr3 became available in a subsequent phase of the same crystal development programme. Consequently, the Flight Spare Model (FSM) gamma-ray spectrometer was retrofitted with a 3-in. CeBr3 crystal and qualified for space. Except for the crystals, the two systems are essentially identical. In this paper, we report on a comparative assessment of the two systems, in terms of their respective spectral properties, as well as their suitability for use in planetary mission with respect to radiation tolerance and their propensity for activation. We also contrast their performance with a Ge detector representative of that flown on MESSENGER and show that: (a) both LaBr3(Ce3+) and CeBr3 provide superior detection systems over HPGe in the context of minimally resourced spacecraft and (b) CeBr3 is a more attractive system than LaBr3(Ce3+) in terms of sensitivities at lower gamma fluxes. Based on the tests, the FM has now been replaced by the FSM on the BepiColombo spacecraft. Thus, CeBr3 now forms the central gamma-ray detection element on the MPO spacecraft. Published by AIP Publishing.
  •  
6.
  • Ulyanov, A., et al. (författare)
  • Performance of a monolithic LaBr3 : Ce crystal coupled to an array of silicon photomultipliers
  • 2016
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 810:810, s. 107-119
  • Tidskriftsartikel (refereegranskat)abstract
    • A gamma-ray detector composed of a single 28×28×20 mm3 LaBr3:Ce crystal coupled to a custom built 4×4 array of silicon photomultipliers was tested over an energy range of 30 keV to 9.3 MeV. The silicon photomultipliers were initially calibrated using 20 ns light pulses generated by a light emitting diode. The photodetector responses measured as a function of the number of incident photons were found to be non-linear and consistent with model predictions. Using corrections for the non-linearity of the silicon photomultipliers, the detector showed a linear response to gamma-rays with energies from 100 keV to the maximum available energy of 9.3 MeV. The energy resolution was found to be 4% FWHM at 662 keV. Despite the large thickness of the scintillator (20 mm) and a 5 mm thick optical window, the detector was capable of measuring the positions of the gamma-ray interaction points. The position resolution was measured at 356 keV and was found to be 8 mm FWHM in the detector plane and 11 mm FWHM for the depth of interaction. The detector can be used as a building block of a larger calorimeter system that is capable of measuring gamma-ray energies up to tens of MeV.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy