SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Greenwood Malcolm) "

Sökning: WFRF:(Greenwood Malcolm)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Buckland, Philip I., Dr. 1973-, et al. (författare)
  • Mid-Devensian climate and landscape in England : new data from Finningley, South Yorkshire
  • 2019
  • Ingår i: Royal Society Open Science. - : Royal Society Publishing. - 2054-5703. ; 6:7
  • Tidskriftsartikel (refereegranskat)abstract
    • While there is extensive evidence for the Late Devensian, less is known about Early and Middle Devensian (approx. 110-30 ka) climates and environments in the UK. The Greenland ice-core record suggests the UK should have endured multiple changes, but the terrestrial palaeo-record lacks sufficient detail for confirmation from sites in the British Isles. Data from deposits at Finningley, South Yorkshire, can help redress this. A channel with organic silts, dated 40 314-39 552 cal a BP, contained plant macrofossil and insect remains showing tundra with dwarf-shrub heath and bare ground. Soil moisture conditions varied from free draining to riparian, with ponds and wetter vegetated areas. The climate was probably low arctic with snow cover during the winter. Mutual climatic range (MCR), based on Coleoptera, shows the mean monthly winter temperatures of -22 to -2 degrees C and summer ones of 8-14 degrees C. Periglacial structures within the basal gravel deposits and beyond the glacial limits indicate cold-climate conditions, including permafrost. A compilation of MCR reconstructions for other Middle Devensian English sites shows that marine isotope stage 3-between 59 and 28 ka-experienced substantial variation in climate consistent with the Greenland ice-core record. The exact correlation is hampered by temporal resolution, but the Finningley site stadial at approximately 40 ka may correlate with the one of the Greenland stadials 7-11.
  •  
2.
  • Newman, David, et al. (författare)
  • Test–retest reliability of rapid whole body and compartmental fat volume quantification on a widebore 3T MR system in normal-weight, overweight, and obese subjects
  • 2016
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 44:6, s. 1464-1473
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo measure the test–retest reliability of rapid (<15 min) whole body and visceral fat volume quantification in normal and obese subjects on a widebore 3T MR system and compare it with conventional manual segmentation.Materials and MethodsThirty participants (body mass index [BMI] 20.1–48.6 kg/m2) underwent two whole-body magnetic resonance imaging (MRI) examinations on a widebore 3T machine using a 2-point Dixon technique. Phase sensitive reconstruction and intensity inhomogeneity correction produced quantitative datasets of total adipose tissue (TAT), abdominal subcutaneous adipose tissue (ASAT), and visceral adipose tissue (VAT). The quantification was performed automatically using nonrigid atlas-based segmentation and compared with manual segmentation (SliceOmatic).ResultsThe mean TAT was 31.74 L with a coefficient of variation (CV) of 0.79% and a coefficient of repeatability (CR) of 0.49 L. The ASAT was 7.92 L with a CV of 2.98% and a CR of 0.46 L. There was no significant difference in the semiautomated and manually segmented VAT (P = 0.73) but there were differences in the reliability of the two techniques. The mean semiautomated VAT was 2.56 L, CV 1.8%, and CR 0.09 L compared to the mean manually segmented VAT of 3.12 L, where the CV was 6.3% and the CR was 0.39 L.ConclusionRapid semiautomated whole body and compartmental fat volume quantification can be derived from a widebore 3T system, for a range of body sizes including obese patients, with “almost perfect” test–retest reliability.
  •  
3.
  • Thomas, Marianna S, et al. (författare)
  • Test-retest reliability of automated whole body and compartmental muscle volume measurements on a wide bore 3T MR system
  • 2014
  • Ingår i: European Radiology. - : Springer Berlin/Heidelberg. - 0938-7994 .- 1432-1084. ; 24:9, s. 2279-2291
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE:To measure the test-retest reproducibility of an automated system for quantifying whole body and compartmental muscle volumes using wide bore 3 T MRI.MATERIALS AND METHODS:Thirty volunteers stratified by body mass index underwent whole body 3 T MRI, two-point Dixon sequences, on two separate occasions. Water-fat separation was performed, with automated segmentation of whole body, torso, upper and lower leg volumes, and manually segmented lower leg muscle volumes.RESULTS:Mean automated total body muscle volume was 19·32 L (SD9·1) and 19·28 L (SD9·12) for first and second acquisitions (Intraclass correlation coefficient (ICC) = 1·0, 95 % level of agreement -0·32-0·2 L). ICC for all automated test-retest muscle volumes were almost perfect (0·99-1·0) with 95 % levels of agreement 1.8-6.6 % of mean volume. Automated muscle volume measurements correlate closely with manual quantification (right lower leg: manual 1·68 L (2SD0·6) compared to automated 1·64 L (2SD 0·6), left lower leg: manual 1·69 L (2SD 0·64) compared to automated 1·63 L (SD0·61), correlation coefficients for automated and manual segmentation were 0·94-0·96).CONCLUSION:Fully automated whole body and compartmental muscle volume quantification can be achieved rapidly on a 3 T wide bore system with very low margins of error, excellent test-retest reliability and excellent correlation to manual segmentation in the lower leg.KEY POINTS:• Sarcopaenia is an important reversible complication of a number of diseases. • Manual quantification of muscle volume is time-consuming and expensive. • Muscles can be imaged using in and out of phase MRI. • Automated atlas-based segmentation can identify muscle groups. • Automated muscle volume segmentation is reproducible and can replace manual measurements.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy