SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Grufman P) "

Sökning: WFRF:(Grufman P)

  • Resultat 1-10 av 23
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Alheim, M, et al. (författare)
  • A flow cytometric crossmatch test for simultaneous detection of antibodies against donor lymphocytes and endothelial precursor cells.
  • 2010
  • Ingår i: Tissue antigens. - : Wiley. - 1399-0039 .- 0001-2815. ; 75:3, s. 269-77
  • Tidskriftsartikel (refereegranskat)abstract
    • Complement-dependent cytotoxicity or flow cytometric lymphocyte crossmatch (LXM) tests may fail to detect clinically significant antibodies (Abs) against non-human leukocyte antigen (HLA). A flow cytometric endothelial precursor cell crossmatch (EPCXM) test (XM-ONE) is available for detection of Abs against donor endothelial precursor cells (EPCs). We showed that lymphocytes co-purified with EPCs can be used in LXM tests allowing simultaneous detection of Abs reactive with donor EPCs and lymphocytes. The lymphocyte population co-purified with EPCs on anti-Tie-2 Ab-coupled magnetic beads contained CD 8(+) and CD 4(+) T-cells, B-cells, and natural killer (NK)- and natural killer T (NKT)-cells. HLA class I antigen expression was slightly higher on CD 3(+) lymphocytes co-purified on Tie-2 Ab beads than on unseparated lymphocytes, whereas HLA class I and II antigen levels on CD 19(+) lymphocytes were not significantly different. Sera from 10 patients with panel-reactive Abs were tested on cells from nine donors using flow cytometric LXM and EPCXM tests. There was a very good correlation (R(2) = 0.94) between the channel shift values obtained on unseparated and Tie-2 Ab bead-isolated T-lymphocytes, whereas the correlation between the channel shift values obtained on the two B-lymphocyte populations was lower (R(2) = 0.71). T- and B-lymphocytes co-purified with EPCs can be used in LXM tests enabling simultaneous detection of donor lymphocyte- and EPC-reactive Abs in a single-tube XM-ONE assay.
  •  
4.
  •  
5.
  •  
6.
  • Breimer, Michael, 1951, et al. (författare)
  • Multicenter evaluation of a novel endothelial cell crossmatch test in kidney transplantation.
  • 2009
  • Ingår i: Transplantation. - 1534-6080. ; 87:4, s. 549-56
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Despite their clinical importance, clinical routine tests to detect anti-endothelial cell antibodies (AECA) in organ transplantation have not been readily available. This multicenter prospective kidney transplantation trial evaluates the efficacy of a novel endothelial cell crossmatch (ECXM) test to detect donor-reactive AECA associated with kidney allograft rejection. METHODS: Pretransplant serum samples from 147 patients were tested for AECA by a novel flow cytometric crossmatch technique (XM-ONE) using peripheral blood endothelial progenitor cells as targets. Patient enrolment was based on acceptance for transplantation determined by donor lymphocyte crossmatch results. RESULTS: Donor-reactive AECA were found in 35 of 147 (24%) patients. A significantly higher proportion of patients with a positive ECXM had rejections (16 of 35, 46%) during the follow-up of at least 3 months compared with those without AECA (13 of 112, 12%; P<0.00005). Both IgG and IgM AECAs were associated with graft rejections. Mean serum creatinine levels were significantly higher in patients with a positive ECXM test at 3 and 6 months posttransplant. CONCLUSIONS: XM-ONE is quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte crossmatches.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 23

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy