SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Häggström Ida 1982 ) "

Search: WFRF:(Häggström Ida 1982 )

  • Result 1-10 of 11
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Berthon, Beatrice, et al. (author)
  • PETSTEP : generation of synthetic PET lesions for fast evaluation of segmentation methods
  • 2015
  • In: Physica medica (Testo stampato). - : Elsevier BV. - 1120-1797 .- 1724-191X. ; 31:8, s. 969-980
  • Journal article (peer-reviewed)abstract
    • Purpose: This work describes PETSTEP (PET Simulator of Tracers via Emission Projection): a faster and more accessible alternative to Monte Carlo (MC) simulation generating realistic PET images, for studies assessing image features and segmentation techniques.Methods: PETSTEP was implemented within Matlab as open source software. It allows generating threedimensional PET images from PET/CT data or synthetic CT and PET maps, with user-drawn lesions and user-set acquisition and reconstruction parameters. PETSTEP was used to reproduce images of the NEMA body phantom acquired on a GE Discovery 690 PET/CT scanner, and simulated with MC for the GE Discovery LS scanner, and to generate realistic Head and Neck scans. Finally the sensitivity (S) and Positive Predictive Value (PPV) of three automatic segmentation methods were compared when applied to the scanner-acquired and PETSTEP-simulated NEMA images.Results: PETSTEP produced 3D phantom and clinical images within 4 and 6 min respectively on a single core 2.7 GHz computer. PETSTEP images of the NEMA phantom had mean intensities within 2% of the scanner-acquired image for both background and largest insert, and 16% larger background Full Width at Half Maximum. Similar results were obtained when comparing PETSTEP images to MC simulated data. The S and PPV obtained with simulated phantom images were statistically significantly lower than for the original images, but led to the same conclusions with respect to the evaluated segmentation methods.Conclusions: PETSTEP allows fast simulation of synthetic images reproducing scanner-acquired PET data and shows great promise for the evaluation of PET segmentation methods.
  •  
2.
  • Häggström, Ida, 1982-, et al. (author)
  • A Monte Carlo study of the dependence of early frame sampling on uncertainty and bias in pharmacokinetic parameters from dynamic PET
  • 2015
  • In: Journal of Nuclear Medicine Technology. - : Society of Nuclear Medicine. - 0091-4916 .- 1535-5675. ; 43:1, s. 53-60
  • Journal article (peer-reviewed)abstract
    • Compartmental modeling of dynamic PET data enables quantifi- cation of tracer kinetics in vivo, through the calculated model parameters. In this study, we aimed to investigate the effect of early frame sampling and reconstruction method on pharmacokinetic parameters obtained from a 2-tissue model, in terms of bias and uncertainty (SD). Methods: The GATE Monte Carlo software was used to simulate 2 · 15 dynamic 3′-deoxy-3′-18F-fluorothymidine (18F-FLT) brain PET studies, typical in terms of noise level and kinetic parameters. The data were reconstructed by both 3- dimensional (3D) filtered backprojection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM) into 6 dynamic image sets with different early frame durations of 1, 2, 4, 6, 10, and 15 s. Bias and SD were evaluated for fitted parameter estimates, calculated from regions of interest. Results: The 2-tissue-model parameter estimates K1, k2, and fraction of arterial blood in tissue depended on early frame sampling, and a sampling of 6–15 s generally minimized bias and SD. The shortest sampling of 1 s yielded a 25% and 42% larger bias than the other schemes, for 3DRP and OSEM, respectively, and a parameter uncertainty that was 10%–70% higher. The schemes from 4 to 15 s were generally not significantly different in regards to bias and SD. Typically, the reconstruction method 3DRP yielded less framesampling dependence and less uncertain results, compared with OSEM, but was on average more biased. Conclusion: Of the 6 sampling schemes investigated in this study, an early frame duration of 6–15 s generally kept both bias and uncertainty to a minimum, for both 3DRP and OSEM reconstructions. Veryshort frames of 1 s should be avoided because they typically resulted in the largest parameter bias and uncertainty. Furthermore, 3DRP may be p
  •  
3.
  • Häggström, Ida, 1982-, et al. (author)
  • Compartment modeling of dynamic brain PET : the impact of scatter corrections on parameter errors
  • 2014
  • In: Medical physics. - : American Association of Physicists in Medicine. - 0094-2405. ; 41:11, s. 111907-
  • Journal article (peer-reviewed)abstract
    • Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated.Methods: The gate Monte Carlo (MC) softwarewas used to perform 2×15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy- 3′-(18F)fluorothymidine (FLT), and were denoted FLT1 and FLT2. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations.Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT1) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT2) for K1, k2, k3, k4,Va, and Ki, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of Ki and k3, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although therewas a slight favor for 3DRP which produced less biased k3 and Ki estimates while OSEM resulted in a less biased Va. The uncertainty in OSEM parameterswas about 26% (FLT1) and 12% (FLT2) larger than for 3DRP although identical postfilters were applied.Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.
  •  
4.
  • Häggström, Ida, 1982, et al. (author)
  • Deep learning for [ 18 F]fluorodeoxyglucose-PET-CT classification in patients with lymphoma: a dual-centre retrospective analysis
  • 2024
  • In: The Lancet Digital Health. - 2589-7500. ; 6:2, s. e114-e125
  • Journal article (peer-reviewed)abstract
    • Background : The rising global cancer burden has led to an increasing demand for imaging tests such as [18F]fluorodeoxyglucose ([18F]FDG)-PET-CT. To aid imaging specialists in dealing with high scan volumes, we aimed to train a deep learning artificial intelligence algorithm to classify [18F]FDG-PET-CT scans of patients with lymphoma with or without hypermetabolic tumour sites. Methods : In this retrospective analysis we collected 16 583 [18F]FDG-PET-CTs of 5072 patients with lymphoma who had undergone PET-CT before or after treatment at the Memorial Sloa Kettering Cancer Center, New York, NY, USA. Using maximum intensity projection (MIP), three dimensional (3D) PET, and 3D CT data, our ResNet34-based deep learning model (Lymphoma Artificial Reader System [LARS]) for [18F]FDG-PET-CT binary classification (Deauville 1–3 vs 4–5), was trained on 80% of the dataset, and tested on 20% of this dataset. For external testing, 1000 [18F]FDG-PET-CTs were obtained from a second centre (Medical University of Vienna, Vienna, Austria). Seven model variants were evaluated, including MIP-based LARS-avg (optimised for accuracy) and LARS-max (optimised for sensitivity), and 3D PET-CT-based LARS-ptct. Following expert curation, areas under the curve (AUCs), accuracies, sensitivities, and specificities were calculated. Findings : In the internal test cohort (3325 PET-CTs, 1012 patients), LARS-avg achieved an AUC of 0·949 (95% CI 0·942–0·956), accuracy of 0·890 (0·879–0·901), sensitivity of 0·868 (0·851–0·885), and specificity of 0·913 (0·899–0·925); LARS-max achieved an AUC of 0·949 (0·942–0·956), accuracy of 0·868 (0·858–0·879), sensitivity of 0·909 (0·896–0·924), and specificity of 0·826 (0·808–0·843); and LARS-ptct achieved an AUC of 0·939 (0·930–0·948), accuracy of 0·875 (0·864–0·887), sensitivity of 0·836 (0·817–0·855), and specificity of 0·915 (0·901–0·927). In the external test cohort (1000 PET-CTs, 503 patients), LARS-avg achieved an AUC of 0·953 (0·938–0·966), accuracy of 0·907 (0·888–0·925), sensitivity of 0·874 (0·843–0·904), and specificity of 0·949 (0·921–0·960); LARS-max achieved an AUC of 0·952 (0·937–0·965), accuracy of 0·898 (0·878–0·916), sensitivity of 0·899 (0·871–0·926), and specificity of 0·897 (0·871–0·922); and LARS-ptct achieved an AUC of 0·932 (0·915–0·948), accuracy of 0·870 (0·850–0·891), sensitivity of 0·827 (0·793–0·863), and specificity of 0·913 (0·889–0·937). Interpretation : Deep learning accurately distinguishes between [18F]FDG-PET-CT scans of lymphoma patients with and without hypermetabolic tumour sites. Deep learning might therefore be potentially useful to rule out the presence of metabolically active disease in such patients, or serve as a second reader or decision support tool. Funding: National Institutes of Health-National Cancer Institute Cancer Center Support Grant.
  •  
5.
  • Häggström, Ida, 1982-, et al. (author)
  • Do scatter and random corrections affect the errors in kinetic parameters in dynamic PET? : a Monte Carlo study
  • 2013
  • In: 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC). - : IEEE conference proceedings. - 9781479905348
  • Conference paper (peer-reviewed)abstract
    • Dynamic positron emission tomography (PET) data can be evaluated by compartmental models, yielding model specific kinetic parameters. For the parameters to be of quantitative use however, understanding and estimation of errors and uncertainties associated with them are crucial.The aim in this study was to investigate the effects of the inclusion of scattered and random counts and their respective corrections on kinetic parameter errors.The MC software GATE was used to simulate two dynamic PET scans of a phantom containing three regions; blood, tissue and a static background. The two sets of time-activity-curves (TACs) used were generated for a 2-tissue compartment model with preset parameter values (K1, k2, k3, k4 and Va). The PET data was reconstructed into 19 frames by both ordered-subset expectation maximization (OSEM) and 3D filtered back-projection with reprojection (3DFBPRP) with normalization and additional corrections (A=attenuation, R=random, S=scatter, C=correction): True counts (AC), true+random counts (ARC), true+scattered counts (ASC) and total counts (ARSC).The results show that parameter estimates from true counts (AC), true+random counts (ARC), true+scattered counts (ASC) and total counts (ARSC) were not significantly different, with the exception of Va where the bias increased with added corrections. Thus, the inclusion of and correction for scattered and random counts did not affect the bias in parameter estimates K1, k2, k3, k4 and Ki. Uncorrected total counts (only AC) resulted in biases of hundreds or even thousands of percent, emphasizing the need for proper corrections. Reconstructions with 3DFBPRP resulted in overall 20-40% less biased estimates compared to OSEM.
  •  
6.
  • Häggström, Ida, 1982- (author)
  • Quantitative methods for tumor imaging with dynamic PET
  • 2014
  • Doctoral thesis (other academic/artistic)abstract
    • There is always a need and drive to improve modern cancer care. Dynamic positron emission tomography (PET) offers the advantage of in vivo functional imaging, combined with the ability to follow the physiological processes over time. In addition, by applying tracer kinetic modeling to the dynamic PET data, thus estimating pharmacokinetic parameters associated to e.g. glucose metabolism, cell proliferation etc., more information about the tissue's underlying biology and physiology can be determined. This supplementary information can potentially be a considerable aid when it comes to the segmentation, diagnosis, staging, treatment planning, early treatment response monitoring and follow-up of cancerous tumors.We have found it feasible to use kinetic parameters for semi-automatic tumor segmentation, and found parametric images to have higher contrast compared to static PET uptake images. There are however many possible sources of errors and uncertainties in kinetic parameters obtained through compartment modeling of dynamic PET data. The variation in the number of detected photons caused by the random nature of radioactive decay, is of course always a major source. Other sources may include: the choice of an appropriate model that is suitable for the radiotracer in question, camera detectors and electronics, image acquisition protocol, image reconstruction algorithm with corrections (attenuation, random and scattered coincidences, detector uniformity, decay) and so on. We have found the early frame sampling scheme in dynamic PET to affect the bias and uncertainty in calculated kinetic parameters, and that scatter corrections are necessary for most but not all parameter estimates. Furthermore, analytical image reconstruction algorithms seem more suited for compartment modeling applications compared to iterative algorithms.This thesis and included papers show potential applications and tools for quantitative pharmacokinetic parameters in oncology, and help understand errors and uncertainties associated with them. The aim is to contribute to the long-term goal of enabling the use of dynamic PET and pharmacokinetic parameters for improvements of today's cancer care.
  •  
7.
  • Häggström, Ida, 1982-, et al. (author)
  • Semi-automatic tumour segmentation by selective navigation in a three-parameter volume, obtained by voxel-wise kinetic modelling of C-11-acetate
  • 2010
  • In: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 139:1-3, s. 214-218
  • Journal article (peer-reviewed)abstract
    • Positron emission tomography (PET) is increasingly used for delineation of tumour tissue in, for example, radiotherapy treatment planning. The most common method used is to outline volumes with a certain per cent uptake over background in a static image. However, PET data can also be collected dynamically and analysed by kinetic models, which potentially represent the underlying biology better. In the present study, a three-parameter kinetic model was used for voxel-wise evaluation of C-11-acetate data of head/neck tumours. These parameters which represent the tumour blood volume, the uptake rate and the clearance rate of the tissue were derived for each voxel using a linear regression method and used for segmentation of active tumour tissue. This feasibility study shows that it is possible to segment images based on derived model parameters. There is, however, room for improvements concerning the PET data acquisition, noise reduction and the kinetic modelling. In conclusion, this early study indicates a strong potential of the method even though no 'true' tumour volume was available for validation.
  •  
8.
  • Jalo, Hoor, 1994, et al. (author)
  • Early identification and characterisation of stroke to support prehospital decision-making using artificial intelligence : A scoping review protocol
  • 2023
  • In: BMJ Open. - : BMJ Publishing Group. - 2044-6055. ; 13:5
  • Journal article (peer-reviewed)abstract
    • Introduction Stroke is a time-critical condition and one of the leading causes of mortality and disability worldwide. To decrease mortality and improve patient outcome by improving access to optimal treatment, there is an emerging need to improve the accuracy of the methods used to identify and characterise stroke in prehospital settings and emergency departments (EDs). This might be accomplished by developing computerised decision support systems (CDSSs) that are based on artificial intelligence (AI) and potential new data sources such as vital signs, biomarkers and image and video analysis. This scoping review aims to summarise literature on existing methods for early characterisation of stroke by using AI. Methods and analysis The review will be performed with respect to the Arksey and O'Malley's model. Peer-reviewed articles about AI-based CDSSs for the characterisation of stroke or new potential data sources for stroke CDSSs, published between January 1995 and April 2023 and written in English, will be included. Studies reporting methods that depend on mobile CT scanning or with no focus on prehospital or ED care will be excluded. Screening will be done in two steps: title and abstract screening followed by full-text screening. Two reviewers will perform the screening process independently, and a third reviewer will be involved in case of disagreement. Final decision will be made based on majority vote. Results will be reported using a descriptive summary and thematic analysis. Ethics and dissemination The methodology used in the protocol is based on information publicly available and does not need ethical approval. The results from the review will be submitted for publication in a peer-reviewed journal. The findings will be shared at relevant national and international conferences and meetings in the field of digital health and neurology. © 2023 BMJ Publishing Group. All rights reserved.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 11
Type of publication
journal article (6)
conference paper (4)
doctoral thesis (1)
Type of content
peer-reviewed (9)
other academic/artistic (2)
Author/Editor
Häggström, Ida, 1982 ... (10)
Larsson, Anne (6)
Karlsson, Mikael (4)
Sörensen, Jens (3)
Johansson, Lennart (3)
Schmidtlein, C. Ross (3)
show more...
Alvén, Jennifer, 198 ... (2)
Yu, Jun, 1962- (2)
Leffler, Klara, 1988 ... (2)
Jood, Katarina, 1966 (1)
Garpebring, Anders (1)
Pikkarainen, Minna (1)
Axelsson, Jan, 1966- (1)
Sjöqvist, Bengt-Arne ... (1)
Axelsson, Jan (1)
Bakidou, Anna, 1996 (1)
Candefjord, Stefan, ... (1)
Zach, Christopher, 1 ... (1)
Salles, Gilles (1)
Berthon, Beatrice (1)
Apte, Aditya (1)
Beattie, Bradley J. (1)
Kirov, Assen S. (1)
Humm, John L. (1)
Marshall, Christophe ... (1)
Spezi, Emiliano (1)
Hricak, Hedvig (1)
Beer, Lucian (1)
Mayerhoefer, Marius ... (1)
Staber, Philipp B. (1)
Östlund, Nils (1)
Karlsson, Mikael, Pr ... (1)
Zhang, HongLei (1)
Schmidtlein, Ross (1)
Leithner, Doris (1)
Campanella, Gabriele (1)
Abusamra, Murad (1)
Chhabra, Shalini (1)
Haug, Alexander (1)
Raderer, Markus (1)
Becker, Anton (1)
Fuchs, Thomas J. (1)
Schöder, Heiko (1)
Larsson, Anne, Docen ... (1)
Dahlbom, Magnus, Pro ... (1)
Jalo, Hoor, 1994 (1)
Seth, Mattias, 1993 (1)
Häggström, Ida Johan ... (1)
Liu, Xixi, 1995 (1)
show less...
University
Umeå University (8)
Chalmers University of Technology (3)
Uppsala University (2)
University of Gothenburg (1)
University of Borås (1)
Language
English (11)
Research subject (UKÄ/SCB)
Engineering and Technology (8)
Natural sciences (7)
Medical and Health Sciences (6)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view