SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Harms Hendrik J) "

Sökning: WFRF:(Harms Hendrik J)

  • Resultat 1-10 av 27
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • de Haan, Stefan, et al. (författare)
  • Parametric imaging of myocardial viability using ¹⁵O-labelled water and PET/CT : comparison with late gadolinium-enhanced CMR
  • 2012
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 39:8, s. 1240-1245
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeThe perfusable tissue index (PTI) is a marker of myocardial viability. Recent technological advances have made it possible to generate parametric PTI images from a single [15O]H2O PET/CT scan. The purpose of this study was to validate these parametric PTI images.MethodsThe study population comprised 46 patients with documented or suspected coronary artery disease who were studied with [15O]H2O PET and late gadolinium-enhanced (LGE) cardiac magnetic resonance imaging (CMR).ResultsOf the 736 myocardial segments included, 364 showed some degree of LGE. PTI and perfusable tissue fraction (PTF) diminished with increasing LGE. The areas under the curve of the PTI and PTF, used to predict (near) transmural LGE on CMR, were 0.86 and 0.87, respectively. Optimal sensitivity and specificity were 91 % and 73 % for PTI and 69 % and 87 % for PTF, respectively.ConclusionPTI and PTF assessed with a single [15O]H2O scan can be utilized as markers of myocardial viability in patients with coronary artery disease.
  •  
2.
  • Danad, Ibrahim, et al. (författare)
  • Carotid artery intima-media thickness, but not coronary artery calcium, predicts coronary vascular resistance in patients evaluated for coronary artery disease
  • 2012
  • Ingår i: European Heart Journal: Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 13:4, s. 317-323
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims There is growing evidence that coronary artery disease (CAD) affects not only the conduit epicardial coronary arteries, but also the microvascular coronary bed. Moreover, coronary microvascular dysfunction (CMVD) often precedes the stage of clinically overt epicardial CAD. Coronary artery calcium (CAC) and carotid intima-media thickness (C-IMT) measured with computed tomography (CT) and ultrasound, respectively, are among the available techniques to non-invasively assess atherosclerotic burden. An increased CAC score and C-IMT have also been associated with CMVD. It is therefore of interest to explore and compare the potential of CAC against C-IMT to predict minimal coronary vascular resistance (CVR). Methods and results We evaluated 120 patients (mean age 56 +/- 9 years, 58 men) without a documented history of CAD in whom and results obstructive CAD was excluded. All patients underwent C-IMT measurements, CAC scoring, and vasodilator stress O-15-water positron emission tomography (PET)/CT, during which the coronary flow reserve (CFR) and minimal CVR were analysed. Minimal CVR increased significantly with increasing tertiles of C-IMT (22 +/- 6, 27 +/- 11, and 28 +/- 9 mmHg mL(-1) min(-1) g(-1), P < 0.01), whereas the CFR was comparable across all C-IMT groups (P = 0.50). Minimal CVR increased significantly with an increase in CAC score (23 +/- 9, 27 +/- 8, 32 +/- 10, and 32 +/- 7 mmHg mL(-1) min(-1) g(-1). P < 0.01), whereas the CFR did not show a significant decrease with higher CAC scores (P = 0.18). Multivariable regression analysis revealed that C-IMT (P = 0.03), but not CAC, was independently associated with minimal CVR. Conclusion C-IMT, but not CAC score, independently predicts minimal CVR in patients with multiple cardiovascular risk factors and suspected of CAD.
  •  
3.
  • Danad, Ibrahim, et al. (författare)
  • Coronary risk factors and myocardial blood flow in patients evaluated for coronary artery disease : a quantitative [15O]H2O PET/CT study
  • 2012
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 39:1, s. 102-112
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundThere has been increasing interest in quantitative myocardial blood flow (MBF) imaging over the last years and it is expected to become a routinely used technique in clinical practice. Positron emission tomography (PET) using [15O]H2O is the established gold standard for quantification of MBF in vivo. A fundamental issue when performing quantitative MBF imaging is to define the limits of MBF in a clinically suitable population. The aims of the present study were to determine the limits of MBF and to determine the relationship among coronary artery disease (CAD) risk factors, gender and MBF in a predominantly symptomatic patient cohort without significant CAD.MethodsA total of 128 patients (mean age 54 ± 10 years, 50 men) with a low to intermediate pretest likelihood of CAD were referred for noninvasive evaluation of CAD using a hybrid PET/computed tomography (PET/CT) scanner. MBF was quantified with [15O]H2O at rest and during adenosine-induced hyperaemia. Obstructive CAD was excluded in these patients by means of invasive or CT-based coronary angiography.ResultsGlobal average baseline MBF values were 0.91 ± 0.34 and 1.09 ± 0.30  ml·min−1·g−1 (range 0.54–2.35  and 0.59–2.75 ml·min−1·g−1) in men and women, respectively (p < 0.01). However, no gender-dependent difference in baseline MBF was seen following correction for rate–pressure product (0.98 ± 0.45 and 1.09 ± 0.30 ml·min−1·g−1 in men and women, respectively; p = 0.08). Global average hyperaemic MBF values were 3.44 ± 1.20 ml·min−1·g−1 in the whole study population, and 2.90 ± 0.85 and 3.78 ± 1.27 ml·min−1·g−1 (range 1.52–5.22 and 1.72–8.15 ml·min−1·g−1) in men and women, respectively (p < 0.001). Multivariate analysis identified male gender, age and body mass index as having an independently negative impact on hyperaemic MBF.ConclusionGender, age and body mass index substantially influence reference values and should be corrected for when interpreting hyperaemic MBF values.
  •  
4.
  • Danad, Ibrahim, et al. (författare)
  • Effect of cardiac hybrid O-15-water PET/CT imaging on downstream referral for invasive coronary angiography and revascularization rate
  • 2014
  • Ingår i: European Heart Journal Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2404 .- 2047-2412. ; 15:2, s. 170-179
  • Tidskriftsartikel (refereegranskat)abstract
    • This study evaluates the impact of hybrid imaging on referral for invasive coronary angiography (ICA) and revascularization rates. A total of 375 patients underwent hybrid O-15-water positron emission tomography (PET)/computed tomography (CT)-based coronary angiography (CTCA) imaging for the evaluation of coronary artery disease (CAD). Downstream treatment strategy within a 60-day period after hybrid PET/CTCA imaging for ICA referral and revascularization was assessed. CTCA examinations were classified as showing no (obstructive) CAD, equivocal (borderline test result), or obstructive CAD, while the PET perfusion images were classified into normal or abnormal. On the basis of CTCA imaging, 182 (49) patients displayed no (obstructive) CAD. Only 10 (5) patients who showed no (obstructive) CAD on CTCA were referred for ICA, which were all negative. An equivocal CT study was observed in 80 (21) patients, among whom 56 (70) showed normal myocardial perfusion imaging (MPI), resulting in referral rates for ICA of 18 for normal MPI and 71 for abnormal MPI, respectively. No revascularizations were performed in the presence of normal MPI, while 59 of those with abnormal MPI were revascularized. CTCA indentified obstructive CAD in 113 (30) patients accompanied in 59 (52) patients with abnormal MPI. Referral rate for ICA was 57 for normal MPI and 88 for those with abnormal MPI, resulting in revascularization rates of 26 and 72, respectively. Hybrid O-15-water PET/CTCA imaging impacts clinical decision-making with regard to referral for ICA and revascularization procedures. Particularly, in the presence of an equivocal or abnormal CTCA, MPI could guide in the decision to refer for ICA and revascularization.
  •  
5.
  • Danad, Ibrahim, et al. (författare)
  • Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient : a [O-15]H2O PET study
  • 2014
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 35:31, s. 2094-U149
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (CAD). The current study aimed to determine the impact of lesion severity as assessed by the fractional flow reserve (FFR) on subendocardial perfusion and the TPG using [O-15]H2O positron emission tomography (PET) imaging in patients evaluated for CAD. Methods and results Sixty-six patients with anginal chest pain were prospectively enrolled and underwent [O-15] H2O myocardial perfusion PET imaging. Subsequently, invasive coronary angiography was performed and FFR obtained in all coronary arteries irrespective of the PET imaging results. Thirty (45%) patients were diagnosed with significant CAD(i.e. FFR <= 0.80), whereas on a per vessel analysis (n = 198), 53 (27%) displayed a positive FFR. Transmural hyperaemic MBF decreased significantly from 3.09 +/- 1.16 to 1.67 +/- 0.57 mL min(-1) g(-1) (P < 0.001) in non-ischaemic and ischaemic myocardium, respectively. The TPG decreased during hyperaemia when compared with baseline (1.20 +/- 0.14 vs. 0.94 +/- 0.17, P < 0.001), and was lower in arteries with a positive FFR (0.97 +/- 0.16 vs. 0.88 +/- 0.18, P < 0.01). ATPG threshold of 0.94 yielded an accuracy to detect CAD of 59%, which was inferior to transmural MBF with an optimal cutoff of 2.20 mL min(-1) g(-1) and an accuracy of 85% (P < 0.001). Diagnostic accuracy of subendocardial perfusion measurements was comparable with transmural MBF (83 vs. 85%, respectively, P = NS). Conclusion Cardiac [O-15]H2O PET imaging is able to distinguish subendocardial from subepicardial perfusion in the myocardium of normal dimensions. Hyperaemic TPG is significantly lower in ischaemic myocardium. This technique can potentially be employed to study subendocardial perfusion impairment in more detail. However, the diagnostic accuracy of subendocardial hyperaemic perfusion and TPG appears to be limited compared with quantitative transmural MBF, warranting further study.
  •  
6.
  •  
7.
  • Harms, Hendrik J., et al. (författare)
  • Association of right ventricular myocardial blood flow with pulmonary pressures and outcome in cardiac amyloidosis
  • 2023
  • Ingår i: JACC Cardiovascular Imaging. - : Elsevier. - 1936-878X .- 1876-7591.
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Cardiac amyloidosis (CA) is a restrictive and infiltrative cardiomyopathy, characterized by increased biventricular filling pressures and low output. Symptoms are predominantly of right heart origin. The role of right ventricular (RV) myocardial blood flow (MBF) in CA has not been studied.Objectives: This study aimed to first associate RV MBF measured by using positron emission tomography (PET) with reference standards of RV pressures and then to explore its prognostic value in CA.Methods: Cardiac PET was performed at rest in 52 patients with CA and 9 healthy control subjects. MBF was quantified from the right and left ventricles by using 11C-acetate, 15O-water, or both (n = 25). RV pressure was measured invasively or by echocardiography. Associations between biventricular MBF toward symptoms, RV function, and outcome (death or acute heart failure) were studied in patients with CA.Results: MBF of the right ventricle (MBFRV) and the ratio of MBFRV and MBF of the left ventricle (MBFRV/LV) for the 2 tracers were significantly correlated (r > 0.92). MBFRV was directly correlated with RV systolic pressures with both tracers (P ≤ 0.005). MBFLV was inversely correlated with wall thickness (P < 0.0001). MBFRV/LV was significantly associated with N-terminal pro–B-type natriuretic peptide levels, New York Heart Association functional class, RV pressures, and RV systolic function (all; P < 0.001). Twenty-six cardiac events (25 deaths) occurred during follow-up (median 44 months). MBFRV/LV higher than 56% was associated with a diagnosis of pulmonary hypertension (AUC: 0.96 [95% CI: 0.91-1.00]; P < 0.0001); and predicted outcome with hazard ratio 9.0 (95% CI: 4.2-14.5), P < 0.0001).Conclusions: Measurements of MBFRV using PET are feasible, as confirmed with 2 different tracers. Imbalance between RV and LV myocardial perfusion is associated with increased RV load and adverse events in cardiac amyloidosis.
  •  
8.
  • Harms, Hendrik J, et al. (författare)
  • Automatic calculation of myocardial external efficiency using a single 11C-acetate PET scan.
  • 2018
  • Ingår i: Journal of Nuclear Cardiology. - : Springer Science and Business Media LLC. - 1071-3581 .- 1532-6551. ; 25:6, s. 1937-1944
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Myocardial external efficiency (MEE) is defined as the ratio of kinetic energy associated with cardiac work [forward cardiac output (FCO)*mean systemic pressure] and the chemical energy from oxygen consumed (MVO2) by the left ventricular mass (LVM). We developed a fully automated method for estimating MEE based on a single 11C-acetate PET scan without ECG-gating.METHODS AND RESULTS: Ten healthy controls, 34 patients with aortic valve stenosis (AVS), and 20 patients with mitral valve regurgitation (MVR) were recruited in a dual-center study. MVO2 was calculated using washout of 11C -acetate activity. FCO and LVM were calculated automatically using dynamic PET and parametric image formation. FCO and LVM were also obtained using cardiac magnetic resonance (CMR) in all subjects. The correlation between MEEPET-CMR and MEEPET was high (r = 0.85, P < 0.001) without significant bias. MEEPET was 23.6 ± 4.2% for controls and was lowered in AVS (17.2 ± 4.3%, P < 0.001) and in MVR (18.0 ± 5.2%, P = 0.004). MEEPET was strongly associated with both NYHA class (P < 0.001) and the magnitude of valvular dysfunction (mean aortic gradient: P < 0.001, regurgitant fraction: P = 0.009).CONCLUSION: A single 11C-acetate PET yields accurate and automated MEE results on different scanners. MEE might provide an unbiased measurement of the phenotypic response to valvular disease.
  •  
9.
  • Harms, Hendrik J, et al. (författare)
  • First-Pass Techniques Applied to Standard Dynamic Cardiac PET : A reappraisal of Old Invasive Techniques to Assess Cardiac Function
  • 2020
  • Ingår i: Seminars in nuclear medicine. - : Elsevier BV. - 0001-2998 .- 1558-4623. ; 50:4, s. 349-356
  • Forskningsöversikt (refereegranskat)abstract
    • Cardiac PET is increasingly performed with dynamic imaging to measure tracer pharmacokinetics in the myocardium. If the early time frames of the PET protocol are sufficiently short and the total amount of injected radioactivity is correctly measured the indicator dilution principle can be applied to PET with most tracers in clinical use, similar to invasive and other noninvasive techniques. The first-pass of the tracer through the heart and lungs can be used to quantify some highly important aspects of cardiovascular function, such as forward cardiac output, transit times, and partial volumes in the central compartments. Additionally, ECG-gated first pass images provide direct access to cardiac volumes and ejection fractions, even for tracers with poor trapping in the myocardial wall, for instance 15O-water. This review summarizes the basic approaches of the indicator dilution principle in clinical use with invasive techniques, and how these techniques can be integrated into a cardiac PET scan.
  •  
10.
  • Harms, Hendrik J., et al. (författare)
  • Noninvasive Quantification of Myocardial C-11-Meta-Hydroxyephedrine Kinetics
  • 2016
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 57:9, s. 1376-1381
  • Tidskriftsartikel (refereegranskat)abstract
    • C-11-meta-hydroxyephedrine (C-11-HED) kinetics in the myocardium can be quantified using a single-tissue-compartment model together with a metabolite-corrected arterial blood sampler input function (BSIF). The need for arterial blood sampling, however, limits clinical applicability. The purpose of this study was to investigate the feasibility of replacing arterial sampling with imaging-derived input function (IDIF) and venous blood samples. Methods: Twenty patients underwent 60-min dynamic C-11-HED PET/CT scans with online arterial blood sampling. Thirteen of these patients also underwent venous blood sampling. Data were reconstructed using both 3 dimensional row-action maximum-likelihood algorithm (3DR) and a time-of-flight (TF) list-mode reconstruction algorithm. For each reconstruction, IDIF results were compared with BSIF results. In addition, IDIF results obtained with venous blood samples and with a transformed venous-to-arterial metabolite correction were compared with results obtained with arterial metabolite corrections. Results: Correlations between IDIF- and BSIF-derived K-1 and V-T were high (r(2) > =0.89 for 3DR and TF). Slopes of the linear fits were significantly different from 1 for K-1, for both 3DR (slope = 0.94) and TF (slope = 1.06). For V-T, the slope of the linear fit was different from 1 for TF (slope = 0.93) but not for 3DR (slope = 0.98). Use of venous blood data introduced a large bias in V-T (r(2) = 0.96, slope = 0.84) and a small bias in K-1 (r(2) = 0.99, slope = 0.98). Use of a second-order polynomial venous-to-arterial transformation was robust and greatly reduced bias in V-T (r(2) = 0.97, slope = 0.99) with no effect on K-1. Conclusion: IDIF yielded precise results for both 3DR and TF. Venous blood samples can be used for absolute quantification of C-11-HED studies, provided a venous-to-arterial transformation is applied. A venous-to-arterial transformation enables noninvasive, absolute quantification of C-11-HED studies.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 27
Typ av publikation
tidskriftsartikel (24)
forskningsöversikt (2)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (24)
övrigt vetenskapligt/konstnärligt (3)
Författare/redaktör
Lubberink, Mark (19)
Sörensen, Jens (14)
Kero, Tanja (11)
Lammertsma, Adriaan ... (11)
Nordström, Jonny (8)
Danad, Ibrahim (6)
visa fler...
Baron, Tomasz (5)
Raijmakers, Pieter G ... (5)
Wikström, Gerhard (3)
Rosengren, Sara (3)
van Royen, Niels (3)
Magnusson, Peter (3)
Granstam, Sven-Olof, ... (3)
Schuit, Robert C (3)
Heymans, Martijn W (3)
Flachskampf, Frank A ... (2)
Flachskampf, Frank, ... (2)
Mörner, Stellan (2)
Windhorst, Albert D (2)
Diamant, Michaela (2)
Tolbod, Lars P (2)
Antoni, Gunnar (1)
Sörensen, Jens, Prof ... (1)
Ahlström, Håkan (1)
Carlson, Kristina (1)
Borre, Michael (1)
Lubberink, Mark, Pro ... (1)
Kvernby, Sofia (1)
Gadler, Fredrik (1)
Pilebro, Björn (1)
Vedin, Ola (1)
Eiskjær, Hans (1)
Appelman, Yolande E. (1)
Astudillo, Rafael (1)
Smit, Egbert F (1)
van der Veldt, Astri ... (1)
Postmus, Pieter E (1)
Hendrikse, N Harry (1)
Bergsten, Johannes (1)
Flachskampf, Frank A ... (1)
Hedin, Eva-Maria (1)
Örndahl, Lovisa Holm (1)
Bjerner, Tomas, 1965 ... (1)
Frøkiaer, Jørgen (1)
Wiggers, Henrik (1)
Boellaard, Ronald (1)
Chen, Weena J Y (1)
Mikkelsen, Fabian (1)
Poulsen, Steen Hvitf ... (1)
Kamali, Parisa (1)
visa färre...
Lärosäte
Uppsala universitet (27)
Umeå universitet (3)
Karolinska Institutet (2)
Språk
Engelska (27)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (21)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy