SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hassig M.) "

Sökning: WFRF:(Hassig M.)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fuselier, S. A., et al. (författare)
  • Ion chemistry in the coma of comet 67P near perihelion
  • 2016
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : Oxford University Press (OUP). - 0035-8711 .- 1365-2966. ; 462, s. S67-S77
  • Tidskriftsartikel (refereegranskat)abstract
    • The coma and the comet-solar wind interaction of comet 67P/Churyumov-Gerasimenko changed dramatically from the initial Rosetta spacecraft encounter in 2014 August through perihelion in 2015 August. Just before equinox (at 1.6 au from the Sun), the solar wind signal disappeared and two regions of different cometary ion characteristics were observed. These 'outer' and 'inner' regions have cometary ion characteristics similar to outside and inside the ion pileup region observed during the Giotto approach to comet 1P/Halley. Rosetta/Double-Focusing Mass Spectrometer ion mass spectrometer observations are used here to investigate the H3O+/H2O+ ratio in the outer and inner regions at 67P/Churyumov-Gerasimenko. The H3O+/H2O+ ratio and the H3O+ signal are observed to increase in the transition from the outer to the inner region and the H3O+ signal appears to be weakly correlated with cometary ion energy. These ion composition changes are similar to the ones observed during the 1P/Halley flyby. Modelling is used to determine the importance of neutral composition and transport of neutrals and ions away from the nucleus. This modelling demonstrates that changes in the H3O+/H2O+ ratio appear to be driven largely by transport properties and only weakly by neutral composition in the coma.
  •  
2.
  • Beth, A., et al. (författare)
  • First in situ detection of the cometary ammonium ion NH4+ (protonated ammonia NH3) in the coma of 67P/C-G near perihelion
  • 2016
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : OXFORD UNIV PRESS. - 0035-8711 .- 1365-2966. ; 462, s. S562-S572
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, we report the first in situ detection of the ammonium ion NH4+ at 67P/Churyumov-Gerasimenko (67P/C-G) in a cometary coma, using the Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA)/Double Focusing Mass Spectrometer (DFMS). Unlike neutral and ion spectrometers onboard previous cometary missions, the ROSINA/DFMS spectrometer, when operated in ion mode, offers the capability to distinguish NH4+ from H2O+ in a cometary coma. We present here the ion data analysis of mass-to-charge ratios 18 and 19 at high spectral resolution and compare the results with an ionospheric model to put these results into context. The model confirms that the ammonium ion NH4+ is one of the most abundant ion species, as predicted, in the coma near perihelion.
  •  
3.
  • Heritier, K. L., et al. (författare)
  • Ion composition at comet 67P near perihelion : Rosetta observations and model-based interpretation
  • 2017
  • Ingår i: Monthly notices of the Royal Astronomical Society. - : OXFORD UNIV PRESS. - 0035-8711 .- 1365-2966. ; 469, s. S427-S442
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the ion composition in the coma of comet 67P with newly detected ion species over the 28-37 u mass range, probed by Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA)/Double Focusing Mass Spectrometer (DFMS). In summer 2015, the nucleus reached its highest outgassing rate and ion-neutral reactions started to take place at low cometocentric distances. Minor neutrals can efficiently capture protons from the ion population, making the protonated version of these neutrals a major ion species. So far, only NH4+ has been reported at comet 67P. However, there are additional neutral species with proton affinities higher than that of water (besides NH3) that have been detected in the coma of comet 67P: CH3OH, HCN, H2CO and H2S. Their protonated versions have all been detected. Statistics showing the number of detections with respect to the number of scans are presented. The effect of the negative spacecraft potential probed by the Rosetta Plasma Consortium/LAngmuir Probe on ion detection is assessed. An ionospheric model has been developed to assess the different ion density profiles and compare them to the ROSINA/DFMS measurements. It is also used to interpret the ROSINA/DFMS observations when different ion species have similar masses, and their respective densities are not high enough to disentangle them using the ROSINA/DFMS high-resolution mode. The different ion species that have been reported in the coma of 67P are summarized and compared with the ions detected at comet 1P/Halley during the Giotto mission.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy