SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hauser Tino) "

Sökning: WFRF:(Hauser Tino)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baensch, Dietmar, et al. (författare)
  • Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators : the NORDIC ICD randomized clinical trial
  • 2015
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 36:37, s. 2500-2507
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. Methods and results Between February 2011 and July 2013, 1077 patients were randomly assigned (1 : 1) to first time ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres, and all ICD shocks were programmed to 40 J irrespective of DF test results. The primary end point was the average first shock efficacy (FSE) for all true ventricular tachycardia and fibrillation (VT/VF) episodes during follow-up. The secondary end points included procedural data, serious adverse events, and mortality. During a median follow-up of 22.8 months, the model-based FSE was found to be non-inferior in patients with an ICD implanted without a DF test, with a difference in FSE of 3.0% in favour of the no DF test [confidence interval (CI) -3.0 to 9.0%, Pnon-inferiority <0.001 for the pre-defined non-inferiority margin of 210%). A total of 112 procedure-related serious adverse events occurred within 30 days in 94 patients (17.6%) tested compared with 89 events in 74 patients (13.9%) not tested (P = 0.095). Conclusion Defibrillation efficacy during follow-up is not inferior in patients with a 40 J ICD implanted without DF testing. Defibrillation testing during first time ICD implantation should no longer be recommended for routine left-sided ICD implantation.
  •  
2.
  •  
3.
  • Shi, K., et al. (författare)
  • Extracting Separation Surfaces of Path Line Oriented Topology in Periodic 2D Time-Dependent Vector Fields
  • 2007
  • Ingår i: Journal of WSCG. - 1213-6964. ; 15:1, s. 75-82
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents an approach to extracting the separation surfaces from periodic 2D time-dependent vector fields based on a recently introduced path line oriented topology. This topology is based on critical path lines which repeat the same spatial cycle per time period. Around those path lines there are areas of similar asymptotic flow behavior basins which are captured by a 2D Poincare map as a discrete dynamical system. Due to pseudo discontinuities in this map and the discrete integration scheme, separatrices between the basins can not be obtained as integral curves. Instead we choose a point-wise approach to segment the Poincare map and apply computer vision algorithms to extract the 2D separation curves. Starting from those curves we integrate separation surfaces which partition the periodic 2D time-dependent vector field into areas of similar path line behavior. We apply our approach to a number of data sets to to demonstrate its utility.
  •  
4.
  • Shi, K., et al. (författare)
  • Path Line Attributes - an Information Visualization Approach to Analyzing the Dynamic Behavior of 3D Time-Dependent Flow Fields
  • 2009
  • Ingår i: Topology-Based Methods in Visualization II. - : Springer. ; , s. 75-88
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • We describe an approach to visually analyzing the dynamic behavior of 3D time-dependent flow fields by considering the behavior of the path lines. At selected positions in the 4D space-time domain, we compute a number of local and global properties of path lines describing relevant features of them. The resulting multivariate data set is analyzed by applying state-of-the-art information visualization approaches in the sense of a set of linked views (scatter plots, parallel coordinates, etc.) with interactive brushing and focus+context visualization. The selected path lines with certain properties are integrated and visualized as colored 3D curves. This approach allows an interactive exploration of intricate 4D flow structures. We apply our method to a number of flow data sets and describe how path line attributes are used for describing characteristic features of these flows.
  •  
5.
  • Shi, K., et al. (författare)
  • Path Line Oriented Topology for Periodic 2D Time-Dependent Vector Fields
  • 2006
  • Ingår i: Proc. Eurographics / IEEE VGTC Symposium on Visualization (EuroVis ’06). ; , s. 139-146
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents an approach to extracting a path line oriented topological segmentation for periodic 2D time-dependent vector fields. Topological methods aiming in capturing the asymptotic behavior of path lines rarely exist because path lines are usually only defined over a fixed time-interval, making statements about their asymptotic behavior impossible. For the data class of periodic vector fields, this restriction does not apply any more. Our approach detects critical path lines as well as basins from which the path lines converge to the critical ones. We demonstrate our approach on a number of test data sets.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy