1.
  • Berndtsson, Maria, et al. (author)
  • Induction of the lysosomal apoptosis pathway by inhibitors of the ubiquitin-proteasome system
  • 2009
  • In: International Journal of Cancer. - : Wiley. - 0020-7136 .- 1097-0215. ; 124:6, s. 1463-1469
  • Journal article (peer-reviewed)abstract
    • The lysosomal apoptosis pathway is a potentially interesting therapeutic target. Since apoptosis involving the lysosomal pathway has been described to involve cathepsins, we screened a drug library for agents that induce cathepsin-dependent apoptosis. Using pharmacological inhibitors and siRNA, we identified 2 structurally related agents (NSC687852 and NSC638646) that induced cathepsin D-dependent caspase-cleavage activity in human breast cancer cells. Both agents were found to induce the mitochondrial apoptosis pathway. NSC687852 and NSC638646 were found to inhibit the activity of ubiquitin isopeptidases and to induce the accumulation of high-molecular-mass ubiquitins in cells. We show that 3 other inhibitors of the proteasome degradation pathway induce lysosomal membrane permeabilization (LMP) and that cathepsin-D siRNA inhibits apoptosis induced by these agents. We conclude that a screen for cathepsin-dependent apoptosis-inducing agents resulted in the identification of ubiquitin isopeptidase inhibitors and that proteasome inhibitors with different mechanisms of action induce LMP and cathepsin D-dependent apoptosis.
  •  
2.
  • Fall, Tove, 1979-, et al. (author)
  • Reference Intervals for Fecal Calprotectin in Adults Using Two Different Extraction Methods in the Uppsala-SCAPIS Cohort
  • 2017
  • In: Clinical Laboratory. - 1433-6510. ; 63:9, s. 1493-1496
  • Journal article (peer-reviewed)abstract
    • Background: Fecal calprotectin measurement is generally recommended to exclude inflammatory bowel disease (IBD) in patients with suspected IBD. A problem with the fecal calprotectin assays so far has been the rather long test-turnaround times. Recently a particle enhanced turbidimetric immunoassay (PETIA) for fecal calprotectin with assay times of approximately 10 minutes has been introduced on the European market. The aim of this study was to define reference intervals for adults with this new fecal calprotectin PETIA using two different extraction methods. Methods: Samples were collected from 382 healthy individuals from the Swedish CArdioPulmonary bioImage Study (SCAPIS) Uppsala cohort in the age range 50 - 65 years. 202 samples were processed with CALEX® Cap extraction device (BÜHLMANN, Schönenbuch, Switzerland) and 180 samples were extracted using weighed samples. The extracted samples were analyzed on a Mindray BS-380 using the fCal Turbo PETIA reagent (BÜHLMANN). Results: The calculated reference values for the Calex device were < 199 µg/g for the whole cohort, < 184 µg/g for females, and < 215 µg/g for males, while the corresponding values for weighed samples were < 153 µg/g for the whole cohort, < 141 µg/g for females, and < 215 µg/g for males. There were no significant statistical differences for calprotectin levels in males and females. Conclusions: The CALEX device yielded slightly higher calprotectin values. As there were no significant gender differences, the study indicates gender independent reference intervals of < 199 µg/g feces for the CALEX device and < 153 µg/g feces for weighed samples in patients in the 50 - 65 year age range.
  •  
3.
  • Helmersson-Karlqvist, Johanna, et al. (author)
  • The Roche Immunoturbidimetric Albumin Method on Cobas c 501 Gives Higher Values Than the Abbott and Roche BCP Methods When Analyzing Patient Plasma Samples
  • 2016
  • In: Journal of clinical laboratory analysis (Print). - : Wiley. - 0887-8013 .- 1098-2825. ; 30:5, s. 677-681
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Serum/plasma albumin is an important and widely used laboratory marker and it is important that we measure albumin correctly without bias. We had indications that the immunoturbidimetric method on Cobas c 501 and the bromocresol purple (BCP) method on Architect 16000 differed, so we decided to study these methods more closely.METHOD: A total of 1,951 patient requests with albumin measured with both the Architect BCP and Cobas immunoturbidimetric methods were extracted from the laboratory system. A comparison with fresh plasma samples was also performed that included immunoturbidimetric and BCP methods on Cobas c 501 and analysis of the international protein calibrator ERM-DA470k/IFCC.RESULTS: The median difference between the Abbott BCP and Roche immunoturbidimetric methods was 3.3 g/l and the Roche method overestimated ERM-DA470k/IFCC by 2.2 g/l. The Roche immunoturbidimetric method gave higher values than the Roche BCP method: y = 1.111x - 0.739, R² = 0.971.CONCLUSION: The Roche immunoturbidimetric albumin method gives clearly higher values than the Abbott and Roche BCP methods when analyzing fresh patient samples. The differences between the two methods were similar at normal and low albumin levels.
  •  
4.
  • Larsson, Anders, et al. (author)
  • Calprotectin is superior to procalcitonin as a sepsis marker and predictor of 30-day mortality in intensive care patients
  • 2020
  • In: Scandinavian Journal of Clinical and Laboratory Investigation. - : Taylor & Francis. - 0036-5513 .- 1502-7686. ; 80:2, s. 156-161
  • Journal article (peer-reviewed)abstract
    • Sepsis is the most frequent cause of death in the intensive care unit (ICU). A rapid and correct diagnosis and initiation of therapy is crucial for improving patient outcomes. The aim of this study was to compare the performance of calprotectin with the more widely used sepsis biomarker procalcitonin (PCT) in ICU patients. The performance of calprotectin and PCT as sepsis and prognostic markers for 30-d mortality was compared in a prospective, observational study in an eight-bed ICU. We investigated concentrations of the biomarkers in plasma collected at admission from all ICU patients admitted during a year (2012-2013, n = 271) together with simplified acute physiology 3 scores (SAPS3) and sequential organ failure assessment (SOFA) scores. The receiver operating characteristic (ROC) analysis showed a higher area under the curve (AUC) value for calprotectin (0.79) than for PCT (0.49) when used as a sepsis marker. The calprotectin concentrations at admission were higher in non-survivors than in survivors at day 30. In our study, calprotectin was superior to PCT for distinguishing between ICU patients with sepsis and non-sepsis patients. Calprotectin also had higher predictive ability regarding 30-d mortality.
  •  
5.
  • Mandic-Havelka, Aleksandra, et al. (author)
  • Turbidimetric Determination of Fecal Calprotectin Using Two Table Top Chemistry Analyzers : Mindray BS-200E and Cobas® c111
  • 2017
  • In: Clinical Laboratory. - 1433-6510. ; 63:5, s. 907-913
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Fecal calprotectin assays are widely used in diagnosis and monitoring of inflammatory bowel disease (IBD) in patients with suspected IBD. The most frequently used technique is ELISA and microtiter plates. Turbidimetric assays for analysis of fecal calprotectin can significantly reduce turnaround time. Many laboratories may be reluctant to run fecal samples on their large chemistry analyzers. The aim of this study was to evaluate fecal calprotectin particle enhanced turbidimetric immunoassay (PETIA) on smaller chemistry analyzers that could be dedicated for fecal samples.METHODS: The BÜHLMANN fCAL® turbo assay was validated on two table top chemistry analyzers, Mindray BS-200E and cobas® c111.RESULTS: The assay was linear in the range between 20 and 1,900 µg/g with a limit of quantification around 20 µg/g on both instruments. The total coefficient of variation was < 7% in the range between 50 and 1,300 µg/g on both instruments. No antigen excess hook effect was observed up to 18,000 µg/g on the Mindray BS-200E and up to 20,000 µg/g on cobas® c111. The BÜHLMANN fCAL® turbo assay showed a high correlation with the BÜHLMANN fCAL® ELISA.CONCLUSIONS: Running the BÜHLMANN fCAL® turbo on Mindray BS-200E or cobas® c111 chemistry analyzers can provide rapid test results without exposing large routine chemistry analyzers to stool samples.
  •  
6.
  • Nilsen, Tom, et al. (author)
  • A novel turbidimetric immunoassay for fecal calprotectin optimized for routine chemistry analyzers
  • 2017
  • In: Journal of clinical laboratory analysis (Print). - : Wiley. - 0887-8013 .- 1098-2825. ; 31:4
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Fecal calprotectin assays are widely used to exclude inflammatory bowel disease (IBD) in patients with suspected IBD. A problem with the fecal calprotectin assays is the rather long test-turnaround times. A particle enhanced turbidimetric immunoassays (PETIA) for fecal calprotectin would reduce test-turnaround times and would permit more laboratories to perform the measurements. The aim of this study was to evaluate a new feces calprotectin PETIA.METHOD: Using routine fecal samples the feces calprotectin PETIA was validated on two chemistry analyzers, Mindray BS-380 and Cobas 501.RESULTS: The assay is linear in the range 11-2000 μg/g, with a limit of quantitation of approximately 10 μg/g. No antigen excess hook effect was observed up to 10 000-15 000 μg/g depending on the instrument used. The turbidimetric method showed a good agreement with the Bühlmann ELISA. The total coefficient of variation was 3%-8% in the 50-100 μg/g range.CONCLUSION: The fecal calprotectin PETIA, fCal Turbo, is well suited for rapid analysis of fecal calprotectin on Mindray BS-380 or Cobas 501 clinical chemistry analyzers. The test results are commutable with Bühlmann fecal MRP8/14 ELISA.
  •  
7.
  • Rollborn, Niclas, et al. (author)
  • Analysis of HbA1c on an automated multicapillary zone electrophoresis system.
  • 2017
  • In: Scandinavian Journal of Clinical and Laboratory Investigation. - : Informa UK Limited. - 0036-5513 .- 1502-7686. ; 77:1, s. 15-18
  • Journal article (peer-reviewed)abstract
    • Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R(2 )= .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R(2 )= .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.
  •  
8.
  • Rollborn, Niclas, et al. (author)
  • Good Agreement Between Hba1c Analyzed Using Capillary Electrophoresis, HPLC, Immunological and Enzymatic Methods
  • 2019
  • In: Journal of Diabetes, Metabolism and its Complications. ; 1:1, s. 1-7
  • Journal article (peer-reviewed)abstract
    • Purpose: Hemoglobin A1c (HbA1c) is an essential marker for assessment of glycemic control in diabetes patients. The aim of this study was to evaluate the agreement between different HbA1c methods.Methodology: We used blood samples to compare HbA1c results analyzed with Capillarys 3 Tera, Roche Tina-Quant HbA1c Gen 3, BioRad Variant II Turbo (3 sites), Mono S® and Abbott Architect enzymatic method. The comparisons were made as paired instrument comparisons with Capillarys 3 Tera.Results: The linear correlations between the HbA1c methods were as follows:Cobas 6000 = 0.982 x Capillarys 3 Tera + 0.975, R² = 0.994;Architect c8000 = 0.982 x Capillarys 3 Tera + 1.064, R² = 0.994; Mono S® = 0.916 x Capillarys 3 Tera + 3.397, R² = 0.965;BioRad Variant II Turbo = 0.923 x Capillarys 3 Tera + 4.062, R² = 0.990; Tosoh G8 = 0.963 x Capillarys 3 Tera + 3.895, R² = 0.996.Conclusions: The different instrument platforms showed the best agreement in the 50-70 mmol/mol interval. Above and below this range the methods separated into 2 groups, one consisting of Capillarys 3 Tera, Roche Tina-Quant and Abbott enzymatic method and the other group consisting of BioRad Variant II Turbo, Tosoh G8 and Mono S®.
  •  