SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Heijnen I.) "

Sökning: WFRF:(Heijnen I.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Canelas, A.B., et al. (författare)
  • Integrated multilaboratory systems biology reveals differences in protein metabolism between two reference yeast strains
  • 2010
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723 .- 2041-1723. ; 1:9
  • Tidskriftsartikel (refereegranskat)abstract
    • The field of systems biology is often held back by difficulties in obtaining comprehensive, high-quality, quantitative data sets. In this paper, we undertook an interlaboratory effort to generate such a data set for a very large number of cellular components in the yeast Saccharomyces cerevisiae, a widely used model organism that is also used in the production of fuels, chemicals, food ingredients and pharmaceuticals. With the current focus on biofuels and sustainability, there is much interest in harnessing this species as a general cell factory. In this study, we characterized two yeast strains, under two standard growth conditions. We ensured the high quality of the experimental data by evaluating a wide range of sampling and analytical techniques. Here we show significant differences in the maximum specific growth rate and biomass yield between the two strains. On the basis of the integrated analysis of the high-throughput data, we hypothesize that differences in phenotype are due to differences in protein metabolism.
  •  
2.
  •  
3.
  • Van Eunen, K., et al. (författare)
  • Measuring enzyme activities under standardized in-vivo like conditions for systems biology
  • 2010
  • Ingår i: FEBS Journal. - : Wiley. - 1742-4658 .- 1742-464X. ; 277:3, s. 749-760
  • Tidskriftsartikel (refereegranskat)abstract
    • Realistic quantitative models require data from many laboratories. Therefore, standardization of experimental systems and assay conditions is crucial. Moreover, standards should be representative of the in vivo conditions. However, most often, enzyme-kinetic parameters are measured under assay conditions that yield the maximum activity of each enzyme. In practice, this means that the kinetic parameters of different enzymes are measured in different buffers, at different pH values, with different ionic strengths, etc. In a joint effort of the Dutch Vertical Genomics Consortium, the European Yeast Systems Biology Network and the Standards for Reporting Enzymology Data Commission, we have developed a single assay medium for determining enzyme-kinetic parameters in yeast. The medium is as close as possible to the in vivo situation for the yeast Saccharomyces cerevisiae, and at the same time is experimentally feasible. The in vivo conditions were estimated for S. cerevisiae strain CEN. PK113-7D grown in aerobic glucose-limited chemostat cultures at an extracellular pH of 5.0 and a specific growth rate of 0.1 h(-1). The cytosolic pH and concentrations of calcium, sodium, potassium, phosphorus, sulfur and magnesium were determined. On the basis of these data and literature data, we propose a defined in vivo-like medium containing 300 mm potassium, 50 mm phosphate, 245 mm glutamate, 20 mm sodium, 2 mm free magnesium and 0.5 mm calcium, at a pH of 6.8. The V(max) values of the glycolytic and fermentative enzymes of S. cerevisiae were measured in the new medium. For some enzymes, the results deviated conspicuously from those of assays done under enzyme-specific, optimal conditions
  •  
4.
  • Damoiseaux, J., et al. (författare)
  • From ANA-screening to antigen-specificity : an EASI-survey on the daily practice in European countries
  • 2014
  • Ingår i: Clinical and Experimental Rheumatology. - 0392-856X .- 1593-098X. ; 32:4, s. 539-546
  • Tidskriftsartikel (refereegranskat)abstract
    • ObjectiveOne of the main goals of the European Autoimmunity Standardisation Initiative (EASI) is the harmonisation of test-algorithms for autoantibodies related to systemic autoimmune rheumatic diseases (SARD).MethodsA questionnaire was used to gather information on methodology, interpretation, and the algorithm for detection of anti-nuclear antibodies (ANA) in relation to their antigen-specificity. The questionnaire was sent to 1200 laboratories in 12 European countries.ResultsThe response rate was 47.2%. The results reveal not only apparent differences between countries, but also within countries.ConclusionAwareness of these differences may as such already stimulate harmonisation, but the observed differences may also direct recommendations that may further contribute to achieving the EASI goal of harmonisation of autoimmune diagnostics for SARD.
  •  
5.
  • Van Hoovels, L., et al. (författare)
  • IgA rheumatoid factor in rheumatoid arthritis
  • 2022
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter GmbH. - 1434-6621 .- 1437-4331. ; 60:10, s. 1617-1626
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives Rheumatoid factor (RF) is a well-established marker for the diagnosis and classification of rheumatoid arthritis (RA). Most studies evaluated IgM RF or isotype-nonspecific total RF assays. We evaluated the added value of IgA RF in this context. Methods An international sample cohort consisting of samples from 398 RA patients and 1073 controls was tested for IgA RF with 3 commercial assays. For all RA patients and 100 controls essential clinical and serological data for ACR/EULAR classification were available. Results The sensitivity of IgA RF for diagnosing RA was lower than the sensitivity of IgM RF. Differences in numerical values between IgA RF assays were observed. With all assays, the highest IgA RF values were found in patients with primary Sjogren's syndrome. Double positivity for IgM RF and IgA RF had a higher specificity for RA than either IgM RF or IgA RF. The sensitivity of double positivity was lower than the sensitivity of either IgA RF or IgM RF. Single positivity for IgA RF was at least as prevalent in controls than in RA patients. Adding IgA RF to IgM RF and anti-citrullinated protein antibodies (ACPA) did not affect RA classification. However, combined positivity for IgA RF, IgM RF and IgG ACPA had a higher specificity and lower sensitivity for RA classification than positivity for either of the antibodies. Conclusions IgA RF showed a lower sensitivity than IgM RF. Combining IgA RF with IgM RF and ACPA did not improve sensitivity of RA classification. Combined positivity (IgA-RF/IgM-RF/ACPA) increased specificity.
  •  
6.
  • Van Hoovels, L., et al. (författare)
  • Multicentre study to improve clinical interpretation of rheumatoid factor and anti-citrullinated protein/peptide antibodies test results
  • 2022
  • Ingår i: RMD Open. - : BMJ. - 2056-5933. ; 8:1
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Rheumatoid factor (RF) and anti-citrullinated protein/peptide antibodies (ACPA) are important biomarkers for diagnosis of rheumatoid arthritis (RA). However, there is poor harmonisation of RF and ACPA assays. The aim of this study was to refine RF and ACPA interpretation across commercial assays. MATERIALS AND METHODS: Six total RF isotype-non-specific assays, 3 RF IgM isotype-specific assays and 9 ACPA immunoglobulin G assays of 13 different companies were evaluated using 398 diagnostic samples from patients with RA and 1073 disease controls. RESULTS: Using cut-offs proposed by the manufacturer, there was a large variability in diagnostic sensitivity and specificity between assays. Thresholds of antibody levels were determined based on predefined specificities and used to define test result intervals. Test result interval-specific likelihood ratios (LRs) were concordant across the different RF and ACPA assays. For all assays, the LR for RA increased with increasing antibody level. Higher LRs were found for ACPA than for RF. ACPA levels associated with LRs >80 were found in a substantial fraction (>22%) of patients with RA. CONCLUSION: Defining thresholds for antibody levels and assigning test result interval-specific LRs allows alignment of clinical interpretation for all RF and ACPA assays. © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
  •  
7.
  • Van Hoovels, L., et al. (författare)
  • Standardisation of ACPA tests: evaluation of a new candidate reference preparation
  • 2022
  • Ingår i: Annals of the Rheumatic Diseases. - : BMJ. - 0003-4967 .- 1468-2060. ; 81:10, s. 1379-1384
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction Commercial assays measuring antibodies to citrullinated protein/peptide (ACPA) show poor quantitative agreement. The diagnostic industry has never adopted the International Union of Immunological Societies-Centers for Disease Control and Prevention (IUIS-CDC) ACPA reference standard. Recently, the National Institute for Biological Standards and Control (NIBSC) prepared a new candidate ACPA standard (18/204). We evaluated both reference materials using different commercially available ACPA assays. Materials and methods This is an international study in which the NIBSC candidate ACPA standard and the IUIS-CDC ACPA reference material were analysed together with 398 diagnostic samples from individuals with rheumatoid arthritis (RA) and in 1073 individuals who did not have RA using nine commercial ACPA assays. Results For both reference materials and samples from individuals with RA and individuals who did not have RA, there were large differences in quantitative ACPA results between assays. For most assays, values for the IUIS-CDC standard were lower than values for NIBSC 18/204 and the IUIS-CDC/NIBSC ratio was comparable for several, but not all assays. When NIBSC 18/204 was used as a calibrator, an improvement in alignment of ACPA results across several of the evaluated assays was obtained. Moreover, NIBSC 18/204 could align clinical interpretation for some but not all assays. Conclusion Adoption of an international standard for ACPA determination is highly desirable. The candidate NIBSC 18/204 standard improved the standardisation and alignment of most ACPA assays and might therefore be recommended to be used as reference in commercial assays.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy