SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hellborg B) "

Sökning: WFRF:(Hellborg B)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Malmqvist, K. G., et al. (författare)
  • PIXE and proton microprobe advances at the Lund Institute of Technology
  • 1989
  • Ingår i: Nuclear Inst. and Methods in Physics Research, B. - 0168-583X. ; 40-41:PART 1, s. 685-689
  • Tidskriftsartikel (refereegranskat)abstract
    • A review of recent advances in high-energy ion beam analysis at the Lund Institute of Technology is presented. A nonvacuum specimen chamber allows chemical speciation using a combination of ion beam analysis and controlled heating. The development of a new versatile scanning proton microbeam based on a new dedicated accelerator, an achromatic triplet lens and an advanced specimen chamber is outlined together with the performance of a microVAX-II/VMEbus-based data acquisition system.
  •  
2.
  •  
3.
  •  
4.
  •  
5.
  • Laitinen, Mikko, et al. (författare)
  • Mobility determination of lead isotopes in glass for retrospective radon measurements
  • 2008
  • Ingår i: Radiation Protection Dosimetry. - : Oxford University Press (OUP). - 1742-3406 .- 0144-8420. ; 131:3, s. 212-216
  • Tidskriftsartikel (refereegranskat)abstract
    • In retrospective radon measurements, the 22-y half life of Pb-210 is used as an advantage. Pb-210 is often considered to be relatively immobile in glass after alpha recoil implanted by Rn-222 progenies. The diffusion of Pb-210 could, however, lead to uncertain wrong retrospective radon exposure estimations if Pb-210 is mobile and can escape from glass, or lost as a result of cleaning-induced surface modification. This diffusion was studied by a radiotracer technique, where Pb-209 was used as a tracer in a glass matrix for which the elemental composition is known. Using the ion guide isotope separator on-line technique, the Pb-209 atoms were implanted into the glass with an energy of 39 keV. The diffusion profiles and the diffusion coefficients were determined after annealing at 470-620 degrees C and serial sectioning by ion sputtering. In addition, the effect of surface cleaning on diffusion was tested. From the Arrhenius fit, the activation enthalpy (H) was determined, which is equal to 3.2 +/- 0.2 eV, and also the pre-exponential factor D-0, in the order of 20 m(2)s(-1). This result confirms the assumption that over a time period of 50 y Pb-209 (and Pb-210) is effectively immobile in the glass. The boundary condition obtained from the measurements had the characteristic of a sink, implying loss of Pb-209 in the topmost surface at high temperatures.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy