SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Herrmann Björn Associate professor) "

Sökning: WFRF:(Herrmann Björn Associate professor)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Christerson, Linus, 1985- (författare)
  • High Resolution Genotyping of Chlamydia trachomatis
  • 2011
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Chlamydia trachomatis is an obligate intracellular bacterium of major human health concern, causing urogential chlamydia infections, lymphogranuloma venereum (LGV) and trachoma. Chlamydia is one of the most common sexually transmitted infections worldwide and can cause infertility. In the first four papers described herein we used a high resolution multilocus sequence typing (MLST) system to investigate the epidemiology of C. trachomatis, and showed that MLST is superior to conventional ompA genotyping with respect to resolution. In the fifth paper we simplified the methodology by developing and validating a multilocus typing (MLT) DNA microarray based on the MLST system. In more detail, MLST analysis of consecutive specimens from 2006 in Örebro County in Sweden, and comparison to specimens from 1999-2000, showed that the new variant C. trachomatis (nvCT) is monoclonal and likely has appeared in recent years. MLST analysis of LGV specimens from men who have sex with men (MSM) showed that the increase of LGV in Europe in the last decade indeed was a clonal outbreak, contrary to the USA where LGV might have been present all along. In the third paper, clinical symptoms could not be correlated with the MLST genotypes, suggesting, together with the combined results of all previous studies, that bacterial factors, if important, need to be understood in the context of host factors. MLST analysis of specimens from a high incidence C. trachomatis area in North Norway revealed interesting epidemiological details concerning unusual genetic variants, the nvCT and MSM, but found no significant difference in genetic diversity compared to two other geographic areas in Norway. Lastly, we developed a MLT array that provides high resolution while being rapid and cost-effective, which makes it an interesting alternative for C. trachomatis genotyping. In conclusion, the MLST system and the MLT array have proven to be useful tools and should now be applied in further investigations to improve our understanding of C. trachomatis epidemiology.
  •  
2.
  • Abdeldaim, Guma M. K. (författare)
  • PCR detection of Streptococcus pneumoniae and Haemophilus influenzae in pneumonia patients
  • 2009
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • PCR is a rapid, reproducible method for nucleic acid detection. However, this technology displays significant deficiencies when applied in clinical microbiology. This work’s aim was to improve current diagnostics and provide sensitive and quantitative real-time PCRs. Paper I describes the development of a sensitive and specific quantitative real-time PCR for the detection of Streptococcus pneumoniae, based on the Spn9802 DNA fragment. Applied to nasopharyngeal aspirates from 166 pneumonia patients, Spn9802 PCR had a sensitivity of 94% and a specificity of 98%. In Paper II the performance of a ply gene PCR for identification of pneumococcal lower respiratory tract infection (LRTI) was evaluated on bronchoalveloar lavage fluids. At the detection limit 103 genome copies/mL, 89% sensitivity but only 43% specificity was achieved. Paper III shows that S. pneumoniae DNA is detectable in plasma from acutely febrile patients. Sensitivities were low (26-42%) for detection of pneumococcal pneumonia, for bacteraemic pneumococcal pneumonia they were 60-70%. Paper IV describes evaluation of four PCR targets for Haemophilus influenzae detection. A real-time PCR based on the P6 gene was developed and applied to 166 CAP patients, using cut-off of 104 genome copies/mL the assay had a sensitivity of 97% and a specificity of 96%. In paper V, the two real-time PCRs presented in papers I and IV were combined with a PCR for detection of Neisseriae meningitidis. The analytical sensitivity of this multiplex real-time PCR was not affected by using a mixture of reagents and a combined DNA standard (S. pneumoniae/H. influenzae) in single tubes. Applied to 156 LRTI patients, this PCR had sensitivities over 90% for S. pneumoniae and H. influenzae, and specificities of 89% and 96%, respectively. In conclusion, real-time PCR assays are useful for the diagnosis of S. pneumoniae and H. influenzae. They enable detection after antibiotic installation, and quantification increases the etiological specificity of pneumonia.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy