SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hilker Michael) "

Sökning: WFRF:(Hilker Michael)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lockhart, Matthew, et al. (författare)
  • Novel infrared polarimeter for the ESO CRIRES plus instrument
  • 2014
  • Ingår i: GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY V. - : SPIE. - 9780819496157
  • Konferensbidrag (refereegranskat)abstract
    • The CRIRES infrared spectrograph at the European Southern Observatory (ESO) Very Large Telescope (VLT) facility will soon receive an upgrade. This upgrade will include the addition of a module for performing high-resolution spectropolarimetry. The polarimetry module will incorporate a novel infrared beamsplitter based on polarization gratings (PGs). The beamsplitter produces a pair of infrared output beams, with opposite circular polarizations, which are then fed into the spectrograph. Visible light passes through the module virtually unaltered and is then available for use by the CRIRES adaptive optics system. We present the design of the polarimetry module and measurements of PG behavior in the 1 to 2.7 mu m wavelength range.
  •  
2.
  • Bílek, Michal, et al. (författare)
  • The galactic acceleration scale is imprinted on globular cluster systems of early-type galaxies of most masses and on red and blue globular cluster subpopulations
  • 2024
  • Ingår i: Astronomy and Astrophysics. - 0004-6361. ; 682
  • Tidskriftsartikel (refereegranskat)abstract
    • Context. Globular clusters (GCs) carry information about the formation histories and gravitational fields of their host galaxies. It was found before that the radial profiles of the volume number density of GCs in GC systems (GCSs) follow broken power laws, while the breaks occur approximately at the a0 radii. These are the radii at which the gravitational fields of the galaxies equal the galactic acceleration scale a0 = 1.2 × 10-10 ms-2 known from the radial acceleration relation or the MOND theory of modified dynamics. Aims. Our main goals here are to explore whether the above results hold true for galaxies of a wider mass range and for the red and blue GC subpopulations. Methods. We exploited catalogs of photometric GC candidates in the Fornax galaxy cluster based on ground and space observations and a new catalog of spectroscopic GCs of NGC1399, the central galaxy of the cluster. For every galaxy, we obtained the parameters of the broken power-law density by fitting the on-sky distribution of the GC candidates, while allowing for a constant density of contaminants. The logarithmic stellar masses of our galaxy sample span 8.0-11.4 M⊙. Results. All investigated GCSs with a suficient number of members show broken power-law density profiles. This holds true for the total GC population and the blue and red subpopulations. The inner and outer slopes and the break radii agree well for the different GC populations. The break radii agree with the a0 radii typically within a factor of two for all GC color subpopulations. The outer slopes correlate better with the a0 radii than with the galactic stellar masses. The break radii of NGC1399 vary in azimuth, such that they are greater toward and against the direction to NGC1404, which tidally interacts with NGC1399.
  •  
3.
  • Kim, Won Keun, et al. (författare)
  • Outcomes and performance of the ACURATE neo2 transcatheter heart valve in clinical practice : one-yearresults of the ACURATE neo2 PMCF Study
  • 2024
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 20:1, s. 85-94
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Transcatheter aortic valve implantation is an effective treatment for patients with aortic stenosis; however, complications related to paravalvular leakage (PVL) persist, including increased risk of mortality, cardiovascular mortality, and rehospitalisation. AIMS: We sought to evaluate the clinical outcomes and valve performance at 1 year in patients with severe aortic stenosis treated with the ACURATE neo2 valve in a post-market clinical setting. METHODS: Valve Academic Research Consortium-2 safety events were assessed up to 1 year. Independent core laboratories evaluated echocardiographic measures of valve performance and hypoattenuated leaflet thickening (HALT; as measured by four-dimensional computed tomography). RESULTS: The study enrolled 250 patients (64% female; mean age: 81 years; baseline Society of Thoracic Surgeons risk score: 2.9±2.0%); 246 patients were implanted with ACURATE neo2. All-cause mortality was 0.8% at 30 days and 5.1% at 1 year. The 1-year rates for stroke and disabling stroke were 3.0% and 1.3%, respectively. Overall, HALT of >50% leaflet involvement of at least one leaflet was present in 9% of patients at 30 days and in 12% of patients at 1 year. No association was observed between the presence of HALT and 1-year clinical or haemodynamic outcomes. Early haemodynamic improvements were maintained up to 1 year (mean aortic valve gradient: 47.6±14.5 mmHg at baseline, 7.6±3.2 mmHg at 1 year; mean aortic valve area: 0.7±0.2 cm2 at baseline, 1.7±0.4 cm2 at 1 year). At 1 year, 99% of patients had mild or no/trace PVL (<1% had moderate PVL; no patient had severe PVL). CONCLUSIONS: The study outcomes confirm favourable performance and safety up to 1 year in patients treated with ACURATE neo2 in routine clinical practice. (ClinicalTrials.gov: NCT04655248).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy