SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hoeschen D.) "

Sökning: WFRF:(Hoeschen D.)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Goriaev, A., et al. (författare)
  • The upgraded TOMAS device : A toroidal plasma facility for wall conditioning, plasma production, and plasma-surface interaction studies
  • 2021
  • Ingår i: Review of Scientific Instruments. - : AMER INST PHYSICS. - 0034-6748 .- 1089-7623. ; 92:2
  • Tidskriftsartikel (refereegranskat)abstract
    • The Toroidal Magnetized System device has been significantly upgraded to enable development of various wall conditioning techniques, including methods based on ion and electron cyclotron (IC/EC) range of frequency plasmas, and to complement plasma-wall interaction research in tokamaks and stellarators. The toroidal magnetic field generated by 16 coils can reach its maximum of 125 mT on the toroidal axis. The EC system is operated at 2.45 GHz with up to 6 kW forward power. The IC system can couple up to 6 kW in the frequency range of 10 MHz-50 MHz. The direct current glow discharge system is based on a graphite anode with a maximum voltage of 1.5 kV and a current of 6 A. A load-lock system with a vertical manipulator allows exposure of material samples. A number of diagnostics have been installed: single- and triple-pin Langmuir probes for radial plasma profiles, a time-of-flight neutral particle analyzer capable of detecting neutrals in the energy range of 10 eV-1000 eV, and a quadrupole mass spectrometer and video systems for plasma imaging. The majority of systems and diagnostics are controlled by the Siemens SIMATIC S7 system, which also provides safety interlocks.
  •  
2.
  •  
3.
  • Moores, B M, et al. (författare)
  • RADIUS--closing the circle on the assessment of imaging performance.
  • 2005
  • Ingår i: Radiation protection dosimetry. - : Oxford University Press (OUP). - 0144-8420 .- 1742-3406. ; 114:1-3, s. 450-7
  • Tidskriftsartikel (refereegranskat)abstract
    • The RADIUS (Radiological Imaging Unification Strategy) project addresses the assessment of image quality in terms of both physical and clinically relevant measures. The aim is to unify our understanding of both types of measure as well as the numerous underlying factors that play a key role in the assessments of imaging performance. In this way it is expected to provide a solid basis for the improvement in radiological safety management, where not only radiation risks are considered but also diagnostic risks of incorrect clinical outcomes (i.e. false positive/false negative). The project has applied a variety of relevant experimental and theoretical methods to this problem, which is generic to medical imaging as a whole. Digital radiography of the chest and the breast has been employed as the clinical imaging domain vehicles for the study. The project addressed the problem from the following directions: role and relevance of pathology, human observer studies including receiver operating characteristics, image quality criteria analysis, structural noise analysis, physical measurements on clinical images, physical measurements on imaging system, modelling of imaging system, modelling of visual processes, modelling of doses delivered and IT-based scientific support strategies. This paper presents an overview of the main outcomes from this project and highlights how the research outcomes actually apply to the real world. In particular, attention will be focused on new and original findings and methods and techniques that have been developed within the framework of the project. The relevance of the project's outcomes to future European research will also be presented.
  •  
4.
  • Lezius, M., et al. (författare)
  • Radiation Induced Absorption in Rare Earth Doped Optical Fibers
  • 2012
  • Ingår i: IEEE Transactions on Nuclear Science. - 0018-9499 .- 1558-1578. ; 59:2, s. 425-433
  • Tidskriftsartikel (refereegranskat)abstract
    • We have investigated the radiation induced absorption (RIA) of optical fibers with high active ion concentration. Comparing our results to the literature leads us to the conclusion that RIA appears to be only weakly dependent on the rare earth dopant concentration. Instead, co-dopants like Al, Ge, or P and manufacturing processes seem to play the major role for the radiation sensitivity. It is also observed that different types of irradiation cause very similar RIA at the same dose applied, with the exception at very high dose rates. It has been studied how RIA can be efficiently reduced via moderate heating. Recovery of up to 70% of the original transmission has been reached after annealing at 450 K. We conclude that radiation induced color centers have weak binding energies between 20 and 40 meV. This suggests that annealing could become a key strategy for an improved survival of rare earth doped fibers in radiative environments, opening up new possibilities for long-term missions in space.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy