SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Holm Niels Ramsing) "

Sökning: WFRF:(Holm Niels Ramsing)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersen, Birgitte Krogsgaard, et al. (författare)
  • Quantitative flow ratio versus fractional flow reserve for guiding percutaneous coronary intervention: design and rationale of the randomised FAVOR III Europe Japan trial.
  • 2023
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213.
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative flow ratio (QFR) is a computation of fractional flow reserve (FFR) based on invasive coronary angiographic images. Calculating QFR is less invasive than measuring FFR and may be associated with lower costs. Current evidence supports the call for an adequately powered randomised comparison of QFR and FFR for the evaluation of intermediate coronary stenosis. The aim of the FAVOR III Europe Japan trial is to investigate if a QFR-based diagnostic strategy yields a non-inferior 12-month clinical outcome compared with a standard FFR-guided strategy in the evaluation of patients with intermediary coronary stenosis. FAVOR III Europe Japan is an investigator-initiated, randomised, clinical outcome, non-inferiority trial scheduled to randomise 2,000 patients with either 1) stable angina pectoris and intermediate coronary stenosis, or 2) indications for functional assessment of at least 1 non-culprit lesion after acute myocardial infarction. Up to 40 international centres will randomise patients to either a QFR-based or a standard FFR-based diagnostic strategy. The primary endpoint of major adverse cardiovascular events is a composite of all-cause mortality, any myocardial infarction, and any unplanned coronary revascularisation at 12 months. QFR could emerge as an adenosine- and wire-free alternative to FFR, making the functional evaluation of intermediary coronary stenosis less invasive and more cost-effective.
  •  
2.
  • Kumsars, Indulis, et al. (författare)
  • Randomised comparison of provisional side branch stenting versus a two-stent strategy for treatment of true coronary bifurcation lesions involving a large side branch : the Nordic-Baltic Bifurcation Study IV
  • 2020
  • Ingår i: Open heart. - : BMJ Publishing Group Ltd. - 2053-3624. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: It is still uncertain whether coronary bifurcations with lesions involving a large side branch (SB) should be treated by stenting the main vessel and provisional stenting of the SB (simple) or by routine two-stent techniques (complex). We aimed to compare clinical outcome after treatment of lesions in large bifurcations by simple or complex stent implantation.Methods: The study was a randomised, superiority trial. Enrolment required a SB >= 2.75 mm, >= 50% diameter stenosis in both vessels, and allowed SB lesion length up to 15 mm. The primary endpoint was a composite of cardiac death, non-procedural myocardial infarction and target lesion revascularisation at 6 months. Two-year clinical follow-up was included in this primary reporting due to lower than expected event rates.Results: A total of 450 patients were assigned to simple stenting (n = 221) or complex stenting (n=229) in 14 Nordic and Baltic centres. Two-year follow-up was available in 218 (98.6%) and 228 (99.5%) patients, respectively. The primary endpoint of major adverse cardiac events (MACE) at 6 months was 5.5% vs 2.2% (risk differences 3.2%, 95% CI -0.2 to 6.8, p=0.07) and at 2 years 12.9% vs 8.4% (HR 0.63, 95% CI 0.35 to 1.13, p = 0.12) after simple versus complex treatment. In the subgroup treated by newer generation drug-eluting stents, MACE was 12.0% vs 5.6% (HR 0.45, 95% CI 0.17 to 1.17, p = 0.10) after simple versus complex treatment.Conclusion: In the treatment of bifurcation lesions involving a large SB with ostial stenosis, routine two-stent techniques did not improve outcome significantly compared with treatment by the simpler main vessel stenting technique after 2 years.
  •  
3.
  • Sejr-Hansen, Martin, et al. (författare)
  • Quantitative flow ratio for immediate assessment of nonculprit lesions in patients with ST-segment elevation myocardial infarction—An iSTEMI substudy
  • 2019
  • Ingår i: Catheterization and Cardiovascular Interventions. - : Wiley. - 1522-1946 .- 1522-726X. ; 94:5, s. 686-692
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: We evaluated the diagnostic performance of quantitative flow ratio (QFR) assessment of nonculprit lesions (NCLs) based on acute setting angiograms obtained in patients with ST-segment elevation myocardial infarction (STEMI) with QFR, fractional flow reserve (FFR), and instantaneous wave-free ratio (iFR) in the staged setting as reference. Background: QFR is an angiography-based approach for the functional evaluation of coronary artery lesions. Methods: This was a post-hoc analysis of the iSTEMI study. NCLs were assessed with iFR in the acute setting and with iFR and FFR at staged (median 13 days) follow-up. Acute and staged QFR values were computed in a core laboratory based on the coronary angiography recordings. Diagnostic cut-off values were ≤0.80 for QFR and FFR, and ≤0.89 for iFR. Results: Staged iFR and FFR data were available for 146 NCLs in 112 patients in the iSTEMI study. Among these, QFR analysis was feasible in 103 (71%) lesions assessed in the acute setting with a mean QFR value of 0.82 (IQR: 0.73–0.91). Staged QFR, FFR, and iFR were 0.80 (IQR: 0.70–0.90), 0.81 (IQR: 0.71–0.88), and 0.91 (IQR: 0.87–0.96), respectively. Classification agreement of acute and staged QFR was 93% (95%Cl: 87–99). The classification agreement of acute QFR was 84% (95%CI: 76–90) using staged FFR as reference and 74% (95%CI: 65–83) using staged iFR as reference. Conclusions: Acute QFR showed a very good diagnostic performance with staged QFR as reference, a good diagnostic performance with staged FFR as reference, and a moderate diagnostic performance with staged iFR as reference.
  •  
4.
  • Westra, Jelmer, et al. (författare)
  • Coronary Artery Stenosis Evaluation by Angiography-Derived FFR Validation by Positron Emission Tomography and Invasive Thermodilution
  • 2023
  • Ingår i: JACC Cardiovascular Imaging. - : ELSEVIER SCIENCE INC. - 1936-878X .- 1876-7591. ; 16:10, s. 1321-1331
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis. OBJECTIVES The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard. METHODS This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (>= 50% diameter stenosis in >= 1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score >= 4 in >= 2 adjacent segments).RESULTS A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis. CONCLUSIONS With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717) (J Am Coll Cardiol Img 2023;16:1321-1331) (c) 2023 by the American College of Cardiology Foundation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy