SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Homer Nils) "

Sökning: WFRF:(Homer Nils)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brown, Kevin M., et al. (författare)
  • Common sequence variants on 20q11.22 confer melanoma susceptibility
  • 2008
  • Ingår i: Nature Genetics. - : Springer Science and Business Media LLC. - 1546-1718 .- 1061-4036. ; 40:7, s. 838-840
  • Tidskriftsartikel (refereegranskat)abstract
    • We conducted a genome-wide association pooling study for cutaneous melanoma and performed validation in samples totaling 2,019 cases and 2,105 controls. Using pooling, we identified a new melanoma risk locus on chromosome 20 (rs910873 and rs1885120), with replication in two further samples (combined P < 1 x 10(-15)). The per allele odds ratio was 1.75 (1.53, 2.01), with evidence for stronger association in early-onset cases.
  •  
2.
  • Brownstein, Catherine A., et al. (författare)
  • An international effort towards developing standards for best practices in analysis, interpretation and reporting of clinical genome sequencing results in the CLARITY Challenge
  • 2014
  • Ingår i: Genome Biology. - : Springer Science and Business Media LLC. - 1465-6906 .- 1474-760X. ; 15:3, s. R53-
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: There is tremendous potential for genome sequencing to improve clinical diagnosis and care once it becomes routinely accessible, but this will require formalizing research methods into clinical best practices in the areas of sequence data generation, analysis, interpretation and reporting. The CLARITY Challenge was designed to spur convergence in methods for diagnosing genetic disease starting from clinical case history and genome sequencing data. DNA samples were obtained from three families with heritable genetic disorders and genomic sequence data were donated by sequencing platform vendors. The challenge was to analyze and interpret these data with the goals of identifying disease-causing variants and reporting the findings in a clinically useful format. Participating contestant groups were solicited broadly, and an independent panel of judges evaluated their performance. Results: A total of 30 international groups were engaged. The entries reveal a general convergence of practices on most elements of the analysis and interpretation process. However, even given this commonality of approach, only two groups identified the consensus candidate variants in all disease cases, demonstrating a need for consistent fine-tuning of the generally accepted methods. There was greater diversity of the final clinical report content and in the patient consenting process, demonstrating that these areas require additional exploration and standardization. Conclusions: The CLARITY Challenge provides a comprehensive assessment of current practices for using genome sequencing to diagnose and report genetic diseases. There is remarkable convergence in bioinformatic techniques, but medical interpretation and reporting are areas that require further development by many groups.
  •  
3.
  • Kalra, Mannudeep K., et al. (författare)
  • Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
  • 2013
  • Ingår i: American Journal of Roentgenology. - : American Roentgen Ray Society (ARRS). - 0361-803X .- 1546-3141. ; 201:2, s. W235-W244
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE. The purpose of this study is to compare sinogram-affirmed iterative reconstruction (SAFIRE) and filtered back projection (FBP) reconstruction of chest CT acquired with 65% radiation dose reduction.SUBJECTS AND METHODS. In this prospective study involving 24 patients (11 women and 13 men; mean [+/- SD] age, 66 +/- 10 years), two scan series were acquired using 100 and 40 Quality Reference mAs over a 10-cm scan length in the chest with a 128-MDCT scanner. The 40 Quality Reference mAs CT projection data were reconstructed with FBP and four settings of Safire (S1, S2, S3, and S4). Six image datasets (FBP with 100 and 40 Quality Reference mAs, and S1, S2, S3, S4 with 40 Quality Reference mAs) were displayed on a DICOM-compliant 55-inch 2-megapixel monitor for blinded evaluation by two thoracic radiologists for number and location of lesions, lesion size, lesion margins, visibility of small structures and fissures, and diagnostic confidence. Objective noise and CT values were measured in thoracic aorta for each image series, and the noise power spectrum was assessed. Data were analyzed with analysis of variance and Wilcoxon signed rank tests.RESULTS. All 186 lesions were seen on 40 Quality Reference mAs SAFIRE images. Diagnostic confidence on SAFIRE images was higher than that for FBP images. Except for the minor blotchy appearance on SAFIRE settings S3 and S4, no significant artifacts were noted. Objective noise with 40 Quality Reference mAs S1 images (21.1 +/- 6.1 SD of HU) was significantly lower than that for 40 Quality Reference mAs FBP images (28.5 +/- 8.1 SD of HU) (p andlt; 0.001). Noise power spectra were identical for SAFIRE and FBP with progressive noise reduction with higher iteration SAFIRE settings.CONCLUSION. Iterative reconstruction (SAFIRE) allows reducing the radiation exposure by approximately 65% without losing diagnostic information in chest CT.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy