SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Hort Ondrej) "

Sökning: WFRF:(Hort Ondrej)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Espinoza, Shirly, et al. (författare)
  • Characterization of the high harmonics source for the VUV ellipsometer at ELI Beamlines
  • 2020
  • Ingår i: Journal of Vacuum Science and Technology B. - : American Institute of Physics (AIP). - 2166-2746 .- 2166-2754. ; 38:2
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper, the authors present the characterization experiments of a 20 fs vacuum ultraviolet beam from a high harmonic generation source. The beam hits a silicon sample and passes a triple reflection gold polarizer located inside an ultrahigh vacuum chamber. The polarizer’s Malus curve was obtained; the total acquisition time for each point of the curve was 30 s. This aims to be the first vacuum ultraviolet time-resolved user station dedicated to ellipsometry. The high harmonic beam is generated by a 12 mJ, 1 kHz, 20 fs, in-house-developed laser and detected by a back-illuminated charge-coupled device. 
  •  
2.
  • Klimesova, Eva, et al. (författare)
  • A multipurpose end-station for atomic, molecular and optical sciences and coherent diffractive imaging at ELI beamlines
  • 2021
  • Ingår i: The European Physical Journal Special Topics. - : Springer Nature. - 1951-6355 .- 1951-6401. ; 230:23, s. 4183-4194
  • Tidskriftsartikel (refereegranskat)abstract
    • We report on the status of a users' end-station, MAC: a Multipurpose station for Atomic, molecular and optical sciences and Coherent diffractive imaging, designed for studies of structure and dynamics of matter in the femtosecond time-domain. MAC is located in the E1 experimental hall on the high harmonic generation (HHG) beamline of the ELI Beamlines facility. The extreme ultraviolet beam from the HHG beamline can be used at the MAC end-station together with a synchronized pump beam (which will cover the NIR/Vis/UV or THz range) for time-resolved experiments on different samples. Sample delivery systems at the MAC end-station include a molecular beam, a source for pure or doped clusters, ultrathin cylindrical or flat liquid jets, and focused beams of substrate-free nanoparticles produced by an electrospray or a gas dynamic virtual nozzle combined with an aerodynamic lens stack. We further present the available detectors: electron/ion time-of-flight and velocity map imaging spectrometers and an X-ray camera, and discuss future upgrades: a magnetic bottle electron spectrometer, production of doped nanodroplets and the planned developments of beam capabilities at the MAC end-station.
  •  
3.
  • Gobom, Johan, et al. (författare)
  • Validation of the LUMIPULSE automated immunoassay for the measurement of core AD biomarkers in cerebrospinal fluid.
  • 2022
  • Ingår i: Clinical chemistry and laboratory medicine. - : Walter de Gruyter GmbH. - 1437-4331 .- 1434-6621. ; 60:2, s. 207-219
  • Tidskriftsartikel (refereegranskat)abstract
    • The core cerebrospinal fluid (CSF) biomarkers; total tau (tTau), phospho-tau (pTau), amyloid β1-42(Aβ 1-42), and the Aβ 1-42/Aβ 1-40 ratio have transformed Alzheimer's disease (AD) research and are today increasingly used in clinical routine laboratories as diagnostic tools. Fully automated immunoassay instruments with ready-to-use assay kits and calibrators has simplified their analysis and improved reproducibility of measurements. We evaluated the analytical performance of the fully automated immunoassay instrument LUMIPULSE G (Fujirebio) for measurement of the four core AD CSF biomarkers and determined cutpoints for AD diagnosis.Comparison of the LUMIPULSE G assays was performed with the established INNOTEST ELISAs (Fujirebio) for hTau Ag, pTau 181, β-amyloid 1-42, and with V-PLEX Plus Aβ Peptide Panel 1 (6E10) (Meso Scale Discovery) for Aβ 1-42/Aβ 1-40, as well as with a LC-MS reference method for Aβ 1-42. Intra- and inter-laboratory reproducibility was evaluated for all assays. Clinical cutpoints for Aβ 1-42, tTau, and pTau was determined by analysis of three cohorts of clinically diagnosed patients, comprising 651 CSF samples. For the Aβ 1-42/Aβ 1-40 ratio, the cutpoint was determined by mixture model analysis of 2,782 CSF samples.The LUMIPULSE G assays showed strong correlation to all other immunoassays (r>0.93 for all assays). The repeatability (intra-laboratory) CVs ranged between 2.0 and 5.6%, with the highest variation observed for β-amyloid 1-40. The reproducibility (inter-laboratory) CVs ranged between 2.1 and 6.5%, with the highest variation observed for β-amyloid 1-42. The clinical cutpoints for AD were determined to be 409ng/L for total tau, 50.2ng/L for pTau 181, 526ng/L for β-amyloid 1-42, and 0.072 for the Aβ 1-42/Aβ 1-40 ratio.Our results suggest that the LUMIPULSE G assays for the CSF AD biomarkers are fit for purpose in clinical laboratory practice. Further, they corroborate earlier presented reference limits for the biomarkers.
  •  
4.
  • Zymakova, Anna, et al. (författare)
  • First experiments with a water-jet plasma X-ray source driven by the novel high-power-high-repetition rate L1 Allegra laser at ELI Beamlines
  • 2021
  • Ingår i: Journal of Synchrotron Radiation. - 0909-0495. ; 28, s. 1778-1785
  • Tidskriftsartikel (refereegranskat)abstract
    • ELI Beamlines is a rapidly progressing pillar of the pan-European Extreme Light Infrastructure (ELI) project focusing on the development and deployment of science driven by high-power lasers for user operations. This work reports the results of a commissioning run of a water-jet plasma X-ray source driven by the L1 Allegra laser, outlining the current capabilities and future potential of the system. The L1 Allegra is one of the lasers developed in-house at ELI Beamlines, designed to be able to reach a pulse energy of 100 mJ at a 1 kHz repetition rate with excellent beam properties. The water-jet plasma X-ray source driven by this laser opens opportunities for new pump-probe experiments with sub-picosecond temporal resolution and inherent synchronization between pump and probe pulses.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy