1.
  • Geistanger, Andrea, et al. (författare)
  • Statistical methods for monitoring the relationship between the IFCC reference measurement procedure for hemoglobin A(1c) and the designated comparison methods in the United States, Japan, and Sweden
  • 2008
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:8, s. 1379-1385
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The American Diabetes Association (ADA)/European Association for the Study of Diabetes (EASD)/International Diabetes Federation GDFAFCC Consensus Statement on the worldwide standardization of HbA(1c) states that"...[HbA(1c)] results are to be reported world-wide in IFCC units...and derived NGSP units...,using the IFCC-NGSP master equation." METHODS: We describe statistical methods to evaluate and monitor the relationships as expressed in master equations (MEs) between the IFCC Reference Measurement procedure (IFCC-RM) and designated comparison methods (DCMs) [US National Glycohemoglobin Standardization Program (NGSP), Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/JSCC), and Mono-S in Sweden]. We applied these statistics, including uncertainty calculations, to 12 studies in which networks of reference laboratories participated, operating the IFCC-RM and DCMs. RESULTS: For NGSP and Mono-S, slope, intercept, and derived percentage HbA(1c) at the therapeutic target show compliance with the respective MEs in all 12 studies. For JDS/JSCC, a slight deviation is seen in slope and derived percentage HbA(1c) in 2 of the 12 studies. Using the MEs, the uncertainty in an assigned value increases from 0.42 mmol/mol HbA(1c) (IFCC-RM) to 0.47 (NGSP), 0.49 (JDS/JSCC), and 0.51 (Mono-S). CONCLUSIONS: We describe sound statistical methods for the investigation of relations between networks of reference laboratories. Application of these statistical methods to the relationship between the JFCC-RM and DCMs in the US, Japan, and Sweden shows that they are suitable for the purpose, and the results support the applicability of the ADA/EASD/lDF/lFCC Consensus Statement on HbA1c measurement. (C) 2008 American Association for Clinical Chemistry.
  •  
2.
  • Jeppsson, Jan-Olof, et al. (författare)
  • Approved IFCC reference method for the measurement of HbA1c in human blood.
  • 2002
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - 1434-6621. ; 40:1, s. 78-89
  • Tidskriftsartikel (refereegranskat)abstract
    • HbA1C is the stable glucose adduct to the N-terminal group of the beta-chain of HbA0. The measurement of HbA1c in human blood is most important for the long-term control of the glycaemic state in diabetic patients. Because there was no internationally agreed reference method the IFCC Working Group on HbA1c Standardization developed a reference method which is here described. In a first step haemoglobin is cleaved into peptides by the enzyme endoproteinase Glu-C, and in a second step the glycated and non-glycated N-terminal hexapeptides of the beta-chain obtained are separated and quantified by HPLC and electrospray ionisation mass spectrometry or in a two-dimensional approach using HPLC and capillary electrophoresis with UV-detection. Both principles give identical results. HbA1c is measured as ratio between the glycated and non-glycated hexapeptides. Calibrators consisting of mixtures of highly purified HbA1c and HbA0 are used. The analytical performance of the reference method has been evaluated by an international network of reference laboratories comprising laboratories from Europe, Japan and the USA. The intercomparison studies of the network showed excellent results with intra-laboratory CVs of 0.5 to 2% and inter-laboratory CVs of 1.4 to 2.3%. Possible interferences have been carefully investigated. Due to the higher specificity of the reference method the results are lower than those generated with most of the present commercial methods which currently are calibrated with unspecific designated comparison methods. The new reference method has been approved by the member societies of the International Federation of Clinical Chemistry and Laboratory Medicine and will be the basis for the future uniform standardization of HbA1c routine assays worldwide.
  •  
3.
  • Mosca, Andrea, et al. (författare)
  • Global standardization of glycated hemoglobin measurement: the position of the IFCC Working Group
  • 2007
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - 1434-6621. ; 45:8, s. 1077-1080
  • Tidskriftsartikel (refereegranskat)abstract
    • The measurement of glycated hemoglobin is central in the monitoring of glycemic control in patients with diabetes. There are at least 30 different laboratory assays commercially available to measure the proportion of HbA1c in blood. In 1995 the IFCC established a Working Group (IFCC WG-HbA1c) to achieve international standardization of HbA1c measurement. The main achievements can be summarized as follows: a) a reference measurement procedure has been established with purified primary calibrators; b) a network of reference laboratories has been developed worldwide; and c) work has begun on implementation of traceability to the IFCC reference system. The IFCC WG-HbA1c recognizes the recommendation of the IFCC-IUPAC Committee on Nomenclature, Properties and Units that the analyte measured by the IFCC reference measurement procedure has been defined as beta N1-deoxyfructosyl-hemoglobin and that the recommended measurement units are mmol/mol. The IFCC WG-HbA1c recommends maintaining the use of the name HbA1c in clinical practice.
  •  
4.
  • Weykamp, Cas, et al. (författare)
  • The IFCC reference measurement system for HbA(1)C: A 6-year progress report
  • 2008
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 54:2, s. 240-248
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The IFCC Reference Measurement System for hemoglobin (Hb)A(1)c (IFCC-RM) has been developed within the framework of metrologic traceability and is embedded in a network of 14 reference laboratories. This paper describes the outcome of 12 intercomparison studies (periodic evaluations to control essential elements of the IFCC-RM). METHODS: Each study included: unknown samples (to test individual network laboratories); known samples (controls); recently manufactured calibrators (to check calculated assigned value); stored calibrators (to test stability) and a calibration-set (to calibrate the IFCC-RM). The unknown samples are measured by use of the IFCC-RM and the designated comparison methods [DCMs; the National Glycohemoglobin Standardization Program (NGSP) in the US, Japanese Diabetes Society/Japanese Society for Clinical Chemistry (JDS/ JSCC) in Japan, and Mono-S in Sweden] are used to investigate the stability of the Master Equation (ME), the relationship between IFCC-RM and DCMs. RESULTS: A total of 105 IFCC-RM data sets were evaluated: 95 were approved, 5 were not, and for 5 no data were submitted. Trend analysis of the MEs, expressed as change in percentage HbA(1)c per year, revealed 0.000% (NGSP, not significant), -0.030%, (JDS/JSCC; significant) and -0.016% (Mono-S; not significant). Evaluation of long-term performance revealed no systematic change over time; 2 laboratories showed significant bias, 1 poor reproducibility. The mean HbA(1)c determined by laboratories performing mass spectrometry (MS) was the same as the mean determined by laboratories using capillary electrophoresis (CE), but the reproducibility at laboratories using CE was better. One batch of new calibrators was not approved. All stored calibrators were stable. CONCLUSION: A sound reference system is in place to ensure continuity and stability of the analytical anchor for HbA(1)c.
  •  