SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Huiskamp René) "

Sökning: WFRF:(Huiskamp René)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ceberg, Crister, et al. (författare)
  • A stochastic model for subcellular dosimetry in boron neutron capture therapy
  • 1995
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 40:11, s. 1819-1830
  • Tidskriftsartikel (refereegranskat)abstract
    • The therapeutic effectiveness of boron neutron capture therapy is highly dependent on the microscopic distribution of the administered boron compound. Two boron compounds with different uptake mechanisms in the tumour cells may thus cause effects of different degrees even if the macroscopic boron concentrations in the tumour tissue are the same. This difference is normally expressed quantitatively by the so-called relative local efficiency (RLE). In this work, a stochastic model for the subcellular dosimetry has been developed. This model can be used to calculate the probability for an energy deposition above a certain threshold level in the cell nucleus due to a single neutron capture reaction. If a threshold cell-kill function is assumed, and if the dose is low enough that multiple energy depositions are rare, the model can also be applied to calculations of the survival probability for a cell population. Subcellular boron distributions in rats carrying RG 2 rat gliomas were measured by subcellular fractionation after administration of two different boron compounds: a sulphydryl boron hydride (BSH) and a boronated porphyrin (BOPP). Based on these data, the RLE factors were then calculated for these compounds using the stochastic model.
  •  
2.
  • Ceberg, Crister, et al. (författare)
  • Performance of sulfhydryl boron hydride in patients with grade III and IV astrocytoma: a basis for boron neutron capture therapy
  • 1995
  • Ingår i: Journal of Neurosurgery. - 0022-3085. ; 83:1, s. 79-85
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigated the rationale of boron neutron capture therapy (BNCT) for the treatment of Grade III and IV astrocytoma. The European Community joint research program on BNCT plans to use sulfhydryl boron hydride (BSH) in clinical trials. The work presented here, examines the performance of BSH in eight patients with Grade III and IV astrocytoma using a measurement technique which precisely correlates the boron uptake with the histology of the tumor and the peritumoral brain. Astrocytomas are exceptionally heterogeneous and spread migrating tumor cells into the surrounding brain. The patients were infused with 50 mg BSH per kilogram of body weight at 12, 18, 24 or 48 hours before surgery. At the time of operation, specimens were obtained of the tumor, skin, muscle, dura, blood, urine, and, when surgically possible, the brain adjacent to tumor. In three patients the intracellular boron distribution was investigated by subcellular fractionation. The blood clearance was biphasic with half-lives of 0.6 and 8.2 hours. After 3 days, approximately 70% of the dose injected was excreted in the urine. The maximum boron concentration in the tumor was 20 ppm, 12 hours after the infusion. The tumor-to-blood ratios ranged between 0.2 and 1.4, with the highest values after 18 to 24 hours. In the brain specimens the boron concentration never exceeded 1 ppm. This work confirms a selective uptake of boron in the tumor compared to the surrounding brain and that boron, to some extent, is incorporated in the tumor cells.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Salford, Leif (2)
Persson, Anders (2)
Ceberg, Crister (2)
Persson, Bertil R (2)
Brun, Arne (2)
Huiskamp, René (2)
visa fler...
Fyhr, Ann-Sofie (1)
visa färre...
Lärosäte
Lunds universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy