1. |
- Wykrzykowska, Joanna J, et al.
(författare)
-
Bioresorbable Scaffolds versus Metallic Stents in Routine PCI.
- 2017
-
Ingår i: New England Journal of Medicine. - 0028-4793 .- 1533-4406. ; 376:24, s. 2319-2328
-
Tidskriftsartikel (refereegranskat)abstract
- BACKGROUND: Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice.METHODS: We randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events.RESULTS: The median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001).CONCLUSIONS: In this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).
|
|
2. |
- Kobo, Ofer, et al.
(författare)
-
Impact of Multisite artery disease on Clinical Outcomes After Percutaneous Coronary Intervention : An Analysis from the e-Ultimaster Registry
- 2023
-
Ingår i: European Heart Journal - Quality of Care and Clinical Outcomes. - : Oxford University Press. - 2058-5225 .- 2058-1742. ; 9:4, s. 417-426
-
Tidskriftsartikel (refereegranskat)abstract
- BACKGROUND: Multisite artery disease is considered a 'malignant' type of atherosclerotic disease associated with an increased cardiovascular risk, but the impact of multisite artery disease on clinical outcomes after percutaneous coronary intervention (PCI) is unknown.METHODS: Patients enrolled in the large, prospective e-Ultimaster study were grouped into 1) those without known prior vascular disease; 2) those with known single-territory vascular disease 3) those with known 2-3 territories (i.e, coronary, cerebrovascular, or peripheral) vascular disease (multisite artery disease). The primary outcome was coronary target lesion failure (TLF) defined as the composite of cardiac death, target vessel-related myocardial infarction, and clinically driven target lesion revascularization at 1-year. Inverse propensity score weighted (IPSW) analysis was performed to address differences in baseline patient and lesion characteristics.RESULTS: Of the 37,198 patients included in the study, 62.3% had no prior known vascular disease, 32.6% had single-territory vascular disease, and 5.1% multisite artery disease. Patients with known vascular disease were older and were more likely to be men and to have more co-morbidities. After IPSW, the TLF rate incrementally increased with the number of diseased vascular beds (3.16%, 4.44% and 6.42% for no, single- and multisite artery disease, p<0.01 for all comparisons). This was also true for all cause death (2.22%, 3.28% and 5.29%, p<0.01 for all comparisons) and cardiac mortality (1.26%, 1.91% and 3.62%, p≤0.01 for all comparisons).CONCLUSIONS: Patients with previously known vascular disease experienced an increased risk for adverse cardiovascular events and mortality post percutaneous coronary intervention. This risk is highest among patients with multisite artery disease.
|
|
3. |
- Vlieger, Selina, et al.
(författare)
-
One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent : a propensity-matched analysis of two international all-comers registries
- 2021
-
Ingår i: Coronary Artery Disease. - : Lippincott Williams & Wilkins. - 0954-6928 .- 1473-5830. ; 32:5, s. 391-396
-
Tidskriftsartikel (refereegranskat)abstract
- OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice.METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events.RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43).CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.
|
|