SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Isaksson Magnus 1978 ) "

Sökning: WFRF:(Isaksson Magnus 1978 )

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andernord, D., et al. (författare)
  • Contact allergy to haptens in the Swedish baseline series: Results from the Swedish Patch Test Register (2010 to 2017)
  • 2022
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 86:3, s. 175-188
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Allergic contact dermatitis has considerable public health impact and causative haptens vary over time. Objectives To report the prevalence of contact allergy to allergens in the Swedish baseline series 2010 to 2017, as registered in the Swedish Patch Test Register. Methods Results and demographic information for patients tested with the Swedish baseline series in 2010 to 2017 were analysed. Results Data for 21 663 individuals (females 69%) were included. Females had significantly more positive patch tests (54% vs 40%). The reaction prevalence rates were highest for nickel sulfate (20.7%), fragrance mix I (7.1%), Myroxylon pereirae (6.9%), potassium dichromate (6.9%), cobalt chloride (6.8%), methylchloroisothiazolinone/methylisothiazolinone (MCI/MI; 6.4%), MI (3.7%), colophonium (3.5%), fragrance mix II (3.2%), and formaldehyde (3.2%). Myroxylon pereirae reaction prevalence increased from 5% in 2010 to 9% in 2017 and that for methyldibromo glutaronitrile from 3.1% to 4.6%. MCI/MI and MI reactions decreased in prevalence after 2014. Nickel reaction prevalence decreased among females aged 10 to 19 years. Conclusions Nickel remains the most common sensitizing agent, with reaction prevalence decreasing among females younger than 20 years. The changes in MCI/MI and MI reaction prevalence mirrored those in Europe. The register can reveal changes in contact allergy prevalence over time among patients patch tested in Sweden.
  •  
2.
  • Göransson, Jenny, 1978-, et al. (författare)
  • A single molecule array for digital targeted molecular analyses
  • 2009
  • Ingår i: Nucleic Acids Research. - England : Oxford University Press. - 0305-1048 .- 1362-4962. ; 37:1, s. e7-
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a new random array format together with a decoding scheme for targeted multiplex digital molecular analyses. DNA samples are analyzed using multiplex sets of padlock or selector probes that create circular DNA molecules upon target recognition. The circularized DNA molecules are amplified through rolling-circle amplification (RCA) to generate amplified single molecules (ASMs). A random array is generated by immobilizing all ASMs on a microscopy glass slide. The ASMs are identified and counted through serial hybridizations of small sets of tag probes, according to a combinatorial decoding scheme. We show that random array format permits at least 10 iterations of hybridization, imaging and dehybridization, a process required for the combinatorial decoding scheme. We further investigated the quantitative dynamic range and precision of the random array format. Finally, as a demonstration, the decoding scheme was applied for multiplex quantitative analysis of genomic loci in samples having verified copy-number variations. Of 31 analyzed loci, all but one were correctly identified and responded according to the known copy-number variations. The decoding strategy is generic in that the target can be any biomolecule which has been encoded into a DNA circle via a molecular probing reaction.
  •  
3.
  • Hagvall, Lina, 1978, et al. (författare)
  • Contact allergy to citral and its constituents geranial and neral, coupled with reactions to the prehapten and prohapten geraniol
  • 2020
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 82:1, s. 31-38
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Citral is commonly used as a fragrance and flavor material and consists of the aldehydes geranial and neral. Citral is included in fragrance mix (FM) II. Geranial and neral have also been identified in autoxidation of geraniol, a fragrance compound present in FM I. Objectives To study contact allergy to citral, geranial, and neral, and concomitant reactivity to oxidized geraniol and fragrance markers of the baseline series. Methods A total of 1476 dermatitis patients with suspected allergic contact dermatitis were patch tested using geranial, neral, and citral, all 3.5% petrolatum (pet.) as well as geraniol 6.0% and oxidized geraniol 11% pet. in addition to the Swedish baseline series. Results Frequencies of positive reactions to citral, geranial, and neral were 2.9%, 3.4% and 1.9%, respectively. Together, citral and geranial gave 4.2% positive patch test reactions in consecutive dermatitis patients. In patients with positive reactions to citral or its components, 25% to 34% reacted to FM II and 61% reacted to oxidized geraniol. Conclusions Patch testing with citral, its components, or oxidized geraniol detects contact allergic reactions not detected using the baseline series. Patch testing with pure geraniol was shown to be of little value. Geranial and neral, although closely chemically related, are concluded to be separate haptens.
  •  
4.
  • Hagvall, Lina, 1978, et al. (författare)
  • Contact allergy to oxidized geraniol among Swedish dermatitis patients-A multicentre study by the Swedish Contact Dermatitis Research Group
  • 2018
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 79:4, s. 232-238
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Geraniol is a widely used fragrance terpene, and is included in fragrance mix I. Geraniol is prone to autoxidation, forming the skin sensitizers geranial, neral, and geraniol-7-hydroperoxide. Oxidized geraniol has previously been patch tested in 1 clinic, giving 1% to 4.6% positive reactions in consecutive patients when tested at 2% to 11%. Aim: To compare test reactions to pure and oxidized geraniol, to compare 2 different test concentrations of oxidized geraniol and to investigate the pattern of concomitant reactions to fragrance markers of the baseline series in a multicentre setting. Methods: One thousand four hundred and seventy-six consecutive patients referred for patch testing were patch tested with geraniol 6% pet. and oxidized geraniol 6% and 11% pet. Results: Pure geraniol 6% pet., oxidized geraniol 6% pet. and oxidized geraniol 11% pet. gave 1%, 3% and 8% positive patch test reactions and 0.7%, 3% and 5% doubtful reactions, respectively. Approximately 50% of the patients with doubtful reactions to oxidized geraniol 6% pet. had positive reactions to oxidized geraniol 11% pet. Conclusions: Oxidized geraniol 11% pet. provides better detection than oxidized geraniol 6% pet. As most patients reacted only to oxidized geraniol, it is important to explore further whether oxidized geraniol should be included in a baseline patch test series.
  •  
5.
  • Barucca, G., et al. (författare)
  • Feasibility studies for the measurement of time-like proton electromagnetic form factors from (p)over-barp -> mu(+)mu(-) at PANDA at FAIR
  • 2021
  • Ingår i: European Physical Journal A. - NEW YORK, USA : Springer Nature. - 1434-6001 .- 1434-601X. ; 57:1
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, vertical bar G(E)vertical bar and vertical bar G(M)vertical bar, using the (p) over barp -> mu(+)mu(-) reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is (p) over barp -> pi(+)pi(-), due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distributions of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.
  •  
6.
  • Barucca, G., et al. (författare)
  • Precision resonance energy scans with the PANDA experiment at FAIR : Sensitivity study for width and line shape measurements of the X(3872)
  • 2019
  • Ingår i: European Physical Journal A. - : SPRINGER. - 1434-6001 .- 1434-601X. ; 55:3
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper summarises a comprehensive Monte Carlo simulation study for precision resonance energy scan measurements. Apart from the proof of principle for natural width and line shape measurements of very narrow resonances with PANDA, the achievable sensitivities are quantified for the concrete example of the charmonium-like X(3872) state discussed to be exotic, and for a larger parameter space of various assumed signal cross-sections, input widths and luminosity combinations. PANDA is the only experiment that will be able to perform precision resonance energy scans of such narrow states with quantum numbers of spin and parities that differ from JPC=1--.
  •  
7.
  • Barucca, G., et al. (författare)
  • Study of excited Ξ baryons with the P¯ ANDA detector
  • 2021
  • Ingår i: European Physical Journal A. - : Springer Nature. - 1434-6001 .- 1434-601X. ; 57:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The study of baryon excitation spectra provides insight into the inner structure of baryons. So far, most of the world-wide efforts have been directed towards N∗ and Δ spectroscopy. Nevertheless, the study of the double and triple strange baryon spectrum provides independent information to the N∗ and Δ spectra. The future antiproton experiment P¯ANDA will provide direct access to final states containing a Ξ¯ Ξ pair, for which production cross sections up to μb are expected in p¯p reactions. With a luminosity of L= 10 31 cm- 2 s- 1 in the first phase of the experiment, the expected cross sections correspond to a production rate of ∼106events/day. With a nearly 4 π detector acceptance, P¯ANDA will thus be a hyperon factory. In this study, reactions of the type p¯p → Ξ¯ +Ξ∗ - as well as p¯p → Ξ¯ ∗ +Ξ- with various decay modes are investigated. For the exclusive reconstruction of the signal events a full decay tree fit is used, resulting in reconstruction efficiencies between 3 and 5%. This allows high statistics data to be collected within a few weeks of data taking.
  •  
8.
  • Barucca, G., et al. (författare)
  • The potential of Λ and Ξ- studies with PANDA at FAIR
  • 2021
  • Ingår i: European Physical Journal A. - : Springer Nature. - 1434-6001 .- 1434-601X. ; 57:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The antiproton experiment PANDA at FAIR is designed to bring hadron physics to a new level in terms of scope, precision and accuracy. In this work, its unique capability for studies of hyperons is outlined. We discuss ground-state hyperons as diagnostic tools to study non-perturbative aspects of the strong interaction, and fundamental symmetries. New simulation studies have been carried out for two benchmark hyperon-antihyperon production channels: p¯ p→ Λ¯ Λ and p¯ p→ Ξ¯ +Ξ-. The results, presented in detail in this paper, show that hyperon-antihyperon pairs from these reactions can be exclusively reconstructed with high efficiency and very low background contamination. In addition, the polarisation and spin correlations have been studied, exploiting the weak, self-analysing decay of hyperons and antihyperons. Two independent approaches to the finite efficiency have been applied and evaluated: one standard multidimensional efficiency correction approach, and one efficiency independent approach. The applicability of the latter was thoroughly evaluated for all channels, beam momenta and observables. The standard method yields good results in all cases, and shows that spin observables can be studied with high precision and accuracy already in the first phase of data taking with PANDA.
  •  
9.
  • Engfeldt, Malin, et al. (författare)
  • Can patch testing with methylchloroisothiazolinone/methylisothiazolinone be optimized using a new diagnostic mix? - A multicenter study from the Swedish Contact Dermatitis Research Group
  • 2020
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 82:5, s. 283-289
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and methylisothiazolinone (MI) are tested to detect contact allergy to these isothiazolinones. Objectives To study if an aqueous patch test preparation with MCI and MI in a mix of 0.015% and 0.2%, respectively, detects more contact allergies than the commonly used preparations of MCI/MI in 0.02% aq. and MI in 0.2% aq. Methods A total of 1555 patients with dermatitis in five Swedish dermatology departments were tested consecutively with MCI/MI 0.215% aq., MCI/MI 0.02% aq., and MI 0.2% aq. Results The share of contact allergy to MCI/MI 0.215% aq., MCI/MI 0.02% aq., and MI 0.2% aq. varied in the test centers between 7.9% and 25.9%, 3.2% and 10.3%, and 5.8% and 12.3%, respectively. MCI/MI 0.215% aq. detected significantly more patch-test positive individuals than both MCI/MI 0.02% aq. (P < .001) and MI 0.2% aq. (P < .001), as well as either one of MCI/MI and MI (P < .001). In the patients only reacting to MCI/MI 0.215% aq., 57.7% were recorded as having a dermatitis that was explained or aggravated by exposure to either MCI/MI or MI. Conclusion The results speak in favor of replacing the preparations MCI/MI 0.02% aq. and MI 0.2% aq. with MCI/MI 0.215% aq. as the screening substance in the Swedish baseline series, which has been implemented in 2020.
  •  
10.
  • Engfeldt, Malin, et al. (författare)
  • Patch Testing with a New Composition of Mercapto Mix: A Multi-centre Study by the Swedish Contact Dermatitis Research Group
  • 2019
  • Ingår i: Acta Dermato-Venereologica. - : Medical Journals Sweden AB. - 0001-5555 .- 1651-2057. ; 99:11, s. 960-963
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigated whether more patients with contact allergies were detected by patch testing with mercapto mix with a higher concentration of 2-mercaptobenzothiazolinone (MBT) than the commonly used mercapto mix. A total of 3,143 dermatitis patients in 5 Swedish dermatology departments were patch-tested with 3 mercapto test preparations: MBT 2.0% petrolatum (pet.); mercapto mix 2.0% pet.; and mercapto mix 3.5% pet. Positive reactions to these mercapto mixes varied between 0-0.50%, 0-0.93%, and 0-1.4%, respectively, in the 5 centres. Numerically, mercapto mix 3.5% pet. detected all positive patients and more patch-test positive patients than did the 2 other substances, but the difference was not statistically significant. The authors recommend replacing mercapto mix 2.0% pet. in the Swedish baseline series with mercapto mix 3.5% pet., since the latter also detected those patients who would have been missed because MBT 2.0% is not included in the Swedish baseline series.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy