SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Jakobsson Jonas K.) "

Sökning: WFRF:(Jakobsson Jonas K.)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aaltonen, H. Laura, et al. (författare)
  • Airspace dimension assessment with nanoparticles as a proposed biomarker for emphysema
  • 2021
  • Ingår i: Thorax. - : BMJ. - 0040-6376 .- 1468-3296. ; 76:10, s. 1040-1043
  • Tidskriftsartikel (refereegranskat)abstract
    • Airspace dimension assessment with nanoparticles (AiDA) is a novel method to measure distal airspace radius non-invasively. In this study, AiDA radii were measured in 618 individuals from the population-based Swedish CArdiopulmonary BioImaging Study, SCAPIS. Subjects with emphysema detected by computed tomography were compared to non-emphysematous subjects. The 47 individuals with mainly mild-to-moderate visually detected emphysema had significantly larger AiDA radii, compared with non-emphysematous subjects (326±48 μm vs 291±36 μm); OR for emphysema per 10 μm: 1.22 (1.13-1.30, p<0.0001). Emphysema according to CT densitometry was similarly associated with larger radii compared with non-emphysematous CT examinations (316±41 μm vs 291 μm±26 μm); OR per 10 μm: 1.16 (1.08-1.24, p<0.0001). The results are in line with comparable studies. The results show that AiDA is a potential biomarker for emphysema in individuals in the general population.
  •  
2.
  • Jakobsson, Jonas K F, et al. (författare)
  • A new method for measuring lung deposition efficiency of airborne nanoparticles in a single breath
  • 2016
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 6
  • Tidskriftsartikel (refereegranskat)abstract
    • Assessment of respiratory tract deposition of nanoparticles is a key link to understanding their health impacts. An instrument was developed to measure respiratory tract deposition of nanoparticles in a single breath. Monodisperse nanoparticles are generated, inhaled and sampled from a determined volumetric lung depth after a controlled residence time in the lung. The instrument was characterized for sensitivity to inter-subject variability, particle size (22, 50, 75 and 100 nm) and breath-holding time (3-20 s) in a group of seven healthy subjects. The measured particle recovery had an inter-subject variability 26-50 times larger than the measurement uncertainty and the results for various particle sizes and breath-holding times were in accordance with the theory for Brownian diffusion and values calculated from the Multiple-Path Particle Dosimetry model. The recovery was found to be determined by residence time and particle size, while respiratory flow-rate had minor importance in the studied range 1-10 L/s. The instrument will be used to investigate deposition of nanoparticles in patients with respiratory disease. The fast and precise measurement allows for both diagnostic applications, where the disease may be identified based on particle recovery, and for studies with controlled delivery of aerosol-based nanomedicine to specific regions of the lungs.
  •  
3.
  • Jakobsson, Jonas K F, et al. (författare)
  • Altered deposition of inhaled nanoparticles in subjects with chronic obstructive pulmonary disease
  • 2018
  • Ingår i: BMC Pulmonary Medicine. - : BioMed Central Ltd.. - 1471-2466. ; 18:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Respiratory tract deposition of airborne particles is a key link to understand their health impact. Experimental data are limited for vulnerable groups such as individuals with respiratory diseases. The aim of this study is to investigate the differences in lung deposition of nanoparticles in the distal lung for healthy subjects and subjects with respiratory disease. Methods: Lung deposition of nanoparticles (50 and 100 nm) was measured after a 10 s breath-hold for three groups: healthy never-smoking subjects (n = 17), asymptomatic (active and former) smokers (n = 15) and subjects with chronic obstructive pulmonary disease (n = 16). Measurements were made at 1300 mL and 1800 mL volumetric lung depth. Each subject also underwent conventional lung function tests, including post bronchodilator FEV1, VC, and diffusing capacity for carbon monoxide, DL,CO. Patients with previously diagnosed respiratory disease underwent a CT-scan of the lungs. Particle lung deposition fraction, was compared between the groups and with conventional lung function tests. Results: We found that the deposition fraction was significantly lower for subjects with emphysema compared to the other subjects (p = 0.001-0.01), but no significant differences were found between healthy never-smokers and smokers. Furthermore, the particle deposition correlated with pulmonary function tests, FEV1%Pred (p < 0.05), FEV1/VC%Pred (p < 0.01) and DL,CO (p < 0.0005) when all subjects were included. Furthermore, for subjects with emphysema, deposition fraction correlated strongly with DL,CO (Pearson's r = 0.80-0.85, p < 0.002) while this correlation was not found within the other groups. Conclusions: Lower deposition fraction was observed for emphysematous subjects and this can be explained by enlarged distal airspaces in the lungs. As expected, deposition increases for smaller particles and deeper inhalation. The observed results have implications for exposure assessment of air pollution and dosimetry of aerosol-based drug delivery of nanoparticles.
  •  
4.
  • Jakobsson, Jonas K.F., et al. (författare)
  • Time dependence of heterogeneous ice nucleation by ambient aerosols : laboratory observations and a formulation for models
  • 2022
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 22:10, s. 6717-6748
  • Tidskriftsartikel (refereegranskat)abstract
    • The time dependence of ice-nucleating particle (INP) activity is known to exist, yet for simplicity it is often omitted in atmospheric models as an approximation. Hitherto, only limited experimental work has been done to quantify this time dependency, for which published data are especially scarce regarding ambient aerosol samples and longer timescales. In this study, the time dependence of INP activity is quantified experimentally for six ambient environmental samples. The experimental approach includes a series of hybrid experiments with alternating constant cooling and isothermal experiments using a recently developed cold-stage setup called the Lund University Cold-Stage (LUCS). This approach of observing ambient aerosol samples provides the optimum realism for representing their time dependence in any model. Six ambient aerosol samples were collected at a station in rural Sweden representing aerosol conditions likely influenced by various types of INPs: marine, mineral dust, continental pristine, continental-polluted, combustion-related and rural continental aerosol. Active INP concentrations were seen to be augmented by about 40% to 100% (or 70% to 200%), depending on the sample, over 2h (or 10h). Mineral dust and rural continental samples displayed the most time dependence. This degree of time dependence observed was comparable to, but weaker than, that seen in previous published works. A general tendency was observed for the natural timescale of the freezing to dilate increasingly with time. The fractional freezing rate was observed to decline steadily with the time since the start of isothermal conditions following a power law. A representation of time dependence for incorporation into schemes of heterogeneous ice nucleation that currently omit it is proposed. Our measurements are inconsistent with the simplest purely stochastic model of INP activity, which assumes that the fractional freezing rate of all unfrozen drops is somehow constant and would eventually overpredict active INPs. In reality, the variability of efficiencies among INPs must be treated with any stochastic theory.
  •  
5.
  • Laura Aaltonen, H., et al. (författare)
  • Airspace Dimension Assessment with nanoparticles reflects lung density as quantified by MRI
  • 2018
  • Ingår i: International Journal of Nanomedicine. - 1176-9114 .- 1178-2013. ; 13, s. 2989-2995
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Airspace Dimension Assessment with inhaled nanoparticles is a novel method to determine distal airway morphology. This is the first empirical study using Airspace Dimension Assessment with nanoparticles (AiDA) to estimate distal airspace radius. The technology is relatively simple and potentially accessible in clinical outpatient settings. Method: Nineteen never-smoking volunteers performed nanoparticle inhalation tests at multiple breath-hold times, and the difference in nanoparticle concentration of inhaled and exhaled gas was measured. An exponential decay curve was fitted to the concentration of recovered nanoparticles, and airspace dimensions were assessed from the half-life of the decay. Pulmonary tissue density was measured using magnetic resonance imaging (MRI). Results: The distal airspace radius measured by AiDA correlated with lung tissue density as measured by MRI (ρ = -0.584; p = 0.0086). The linear intercept of the logarithm of the exponential decay curve correlated with forced expiratory volume in one second (FEV1) (ρ = 0.549; p = 0.0149). Conclusion: The AiDA method shows potential to be developed into a tool to assess conditions involving changes in distal airways, eg, emphysema. The intercept may reflect airway properties; this finding should be further investigated.
  •  
6.
  • Löndahl, Jakob, et al. (författare)
  • Do nanoparticles provide a new opportunity for diagnosis of distal airspace disease?
  • 2017
  • Ingår i: International Journal of Nanomedicine. - 1176-9114. ; 12, s. 41-51
  • Tidskriftsartikel (refereegranskat)abstract
    • There is a need for efficient techniques to assess abnormalities in the peripheral regions of the lungs, for example, for diagnosis of pulmonary emphysema. Considerable scientific efforts have been directed toward measuring lung morphology by studying recovery of inhaled micron-sized aerosol particles (0.4-1.5 μm). In contrast, it is suggested that the recovery of inhaled airborne nanoparticles may be more useful for diagnosis. The objective of this work is to provide a theoretical background for the use of nanoparticles in measuring lung morphology and to assess their applicability based on a review of the literature. Using nanoparticles for studying distal airspace dimensions is shown to have several advantages over other aerosol-based methods. 1) Nanoparticles deposit almost exclusively by diffusion, which allows a simpler breathing maneuver with minor artifacts from particle losses in the oropharyngeal and upper airways. 2) A higher breathing flow rate can be utilized, making it possible to rapidly inhale from residual volume to total lung capacity (TLC), thereby eliminating the need to determine the TLC before measurement. 3) Recent studies indicate better penetration of nanoparticles than micron-sized particles into poorly ventilated and diseased regions of the lungs; thus, a stronger signal from the abnormal parts is expected. 4) Changes in airspace dimensions have a larger impact on the recovery of nanoparticles. Compared to current diagnostic techniques with high specificity for morphometric changes of the lungs, computed tomography and magnetic resonance imaging with hyperpolarized gases, an aerosol-based method is likely to be less time consuming, considerably cheaper, simpler to use, and easier to interpret (providing a single value rather than an image that has to be analyzed). Compared to diagnosis by carbon monoxide (DL,CO), the uptake of nanoparticles in the lung is not affected by blood flow, hemoglobin concentration or alterations of the alveolar membranes, but relies only on lung morphology.
  •  
7.
  • Stranne, Christian, et al. (författare)
  • The climate sensitivity of northern Greenland fjords is amplified through sea-ice damming
  • 2021
  • Ingår i: Communications Earth & Environment. - : Springer Science and Business Media LLC. - 2662-4435. ; 2:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Record-high air temperatures were observed over Greenland in the summer of 2019 and melting of the northern Greenland Ice Sheet was particularly extensive. Here we show, through direct measurements, that near surface ocean temperatures in Sherard Osborn Fjord, northern Greenland, reached 4 °C in August 2019, while in the neighboring Petermann Fjord, they never exceeded 0 °C. We show that this disparity in temperature between the two fjords occurred because thick multi-year sea ice at the entrance of Sherard Osborn Fjord trapped the surface waters inside the fjord, which led to the formation of a warm and fresh surface layer. These results suggest that the presence of multi-year sea ice increases the sensitivity of Greenland fjords abutting the Arctic Ocean to climate warming, with potential consequences for the long-term stability of the northern sector of the Greenland Ice Sheet.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy