1. |
- Messi, F., et al.
(författare)
-
The neutron-tagging facility at Lund University
- 2020
-
Ingår i: Modern Neutron Detection : Proceedings of a Technical Meeting - Proceedings of a Technical Meeting. - 1011-4289. - 9789201265203 - 9789201266200 ; :1935, s. 287-297
-
Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
- Over the last decades, the field of thermal neutron detection has overwhelmingly employed He-3-based technologies. The He-3 crisis together with the forthcoming establishment of the European Spallation Source have necessitated the development of new technologies for neutron detection. Today, several promising He-3-free candidates are under detailed study and need to be validated. This validation process is in general long and expensive. The study of detector prototypes using neutron-emitting radioactive sources is a cost-effective solution, especially for preliminary investigations. That said, neutron-emitting sources have the general disadvantage of broad, structured, emitted-neutron energy ranges. Further, the emitted neutrons often compete with unwanted backgrounds of gamma-rays, alpha-particles, and fission-fragments. By blending experimental infrastructure such as shielding to provide particle beams with neutron-detection techniques such as tagging, disadvantages may be converted into advantages. In particular, a technique known as tagging involves exploiting the mixed-field generally associated with a neutron-emitting source to determine neutron time-of-flight and thus energy on an event-by-event basis. This allows for the definition of low-cost, precision neutron beams. The Source-Testing Facility, located at Lund University in Sweden and operated by the SONNIG Group of the Division of Nuclear Physics, was developed for just such low-cost studies. Precision tagged-neutron beams derived from radioactive sources are available around-the-clock for advanced detector diagnostic studies. Neutron measurements performed at the Source Testing Facility are thus cost-effective and have a very low barrier for entry. In this paper, we present an overview of the project.
|
|
2. |
- Al Jebali, Ramsey, et al.
(författare)
-
Recent Developments SoNDe High-Flux Detector Project
- 2018
-
Ingår i: Recent Developments SoNDe High-Flux Detector Project.
-
Konferensbidrag (refereegranskat)abstract
- New high-flux and high-brilliance neutron sources demand a higher count-rate capability in neutron detectors. In order to achieve that goal, the Solid-State Neutron Detector (SoNDe) project is developing a scintillation-based neutron detector. It will be capable of fully exploiting the available flux at small-angle neutron scattering (SANS) instruments at high brilliance sources, such as SKADI at the European Spallation Source (ESS). The read-out of the scintillator is based on a pixelized multi-anode PMT (MaPMT), where each pixel is treated separately. In addition to enabling higher achievable count-rates, one of the design goals was to develop a modular and scalable solution that can also be used in other instruments or even contexts, such as for laboratory setups. This has been achieved by combining the complete read-out electronics along with the MaPMT into modules that can be controlled and read-out individually via a network without additional any infrastructure. An overview of the present state of development and current test results is presented, highlighting the results of previously published project reports.
|
|
3. |
- Rofors, E., et al.
(författare)
-
Response of a Li-glass/multi-anode photomultiplier detector to alpha-particles from Am-241
- 2019
-
Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 929, s. 90-96
-
Tidskriftsartikel (refereegranskat)abstract
- The response of a position-sensitive Li-glass scintillator detector to alpha-particles from a collimated Am-241 source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 x 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
|
|
4. |
- Rofors, E., et al.
(författare)
-
Response of a Li-glass/multi-anode photomultiplier detector to α-particles from 241 Am
- 2019
-
Ingår i: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. - : Elsevier BV. - 0168-9002. ; 929, s. 90-96
-
Tidskriftsartikel (refereegranskat)abstract
- The response of a position-sensitive Li-glass scintillator detector to α-particles from a collimated 241 Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 × 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position and in general several pixels will register a signal (a hit) above a given threshold. The effect of this threshold on hit multiplicity is studied, with a view to optimize the single-hit efficiency of the detector.
|
|