SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Jansson Sabine) "

Search: WFRF:(Jansson Sabine)

  • Result 1-10 of 37
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Attauabi, Mohamed, et al. (author)
  • Influence of Genetics, Immunity and the Microbiome on the Prognosis of Inflammatory Bowel Disease (IBD Prognosis Study) : the protocol for a Copenhagen IBD Inception Cohort Study
  • 2022
  • In: BMJ Open. - : BMJ Publishing Group Ltd. - 2044-6055. ; 12:6, s. e055779-e055779
  • Journal article (peer-reviewed)abstract
    • Introduction: Inflammatory bowel diseases (IBD), encompassing Crohn's disease and ulcerative colitis, are chronic, inflammatory diseases of the gastrointestinal tract. We have initiated a Danish population-based inception cohort study aiming to investigate the underlying mechanisms for the heterogeneous course of IBD, including need for, and response to, treatment.Methods and analysis: IBD Prognosis Study is a prospective, population-based inception cohort study of unselected, newly diagnosed adult, adolescent and paediatric patients with IBD within the uptake area of Hvidovre University Hospital and Herlev University Hospital, Denmark, which covers approximately 1 050 000 inhabitants (~20% of the Danish population). The diagnosis of IBD will be according to the Porto diagnostic criteria in paediatric and adolescent patients or the Copenhagen diagnostic criteria in adult patients. All patients will be followed prospectively with regular clinical examinations including ileocolonoscopies, MRI of the small intestine, validated patient-reported measures and objective examinations with intestinal ultrasound. In addition, intestinal biopsies from ileocolonoscopies, stool, rectal swabs, saliva samples, swabs of the oral cavity and blood samples will be collected systematically for the analysis of biomarkers, microbiome and genetic profiles. Environmental factors and quality of life will be assessed using questionnaires and, when available, automatic registration of purchase data. The occurrence and course of extraintestinal manifestations will be evaluated by rheumatologists, dermatologists and dentists, and assessed by MR cholangiopancreatography, MR of the spine and sacroiliac joints, ultrasonography of peripheral joints and entheses, clinical oral examination, as well as panoramic radiograph of the jaws. Fibroscans and dual-energy X-ray absorptiometry scans will be performed to monitor occurrence and course of chronic liver diseases, osteopenia and osteoporosis.Ethics and dissemination: This study has been approved by Ethics Committee of the Capital Region of Denmark (approval number: H-20065831). Study results will be disseminated through publication in international scientific journals and presentation at (inter)national conferences.
  •  
2.
  • Berndt, Sonja I., et al. (author)
  • Genome-wide meta-analysis identifies 11 new loci for anthropometric traits and provides insights into genetic architecture
  • 2013
  • In: Nature Genetics. - : Springer Science and Business Media LLC. - 1061-4036 .- 1546-1718. ; 45:5, s. 501-U69
  • Journal article (peer-reviewed)abstract
    • Approaches exploiting trait distribution extremes may be used to identify loci associated with common traits, but it is unknown whether these loci are generalizable to the broader population. In a genome-wide search for loci associated with the upper versus the lower 5th percentiles of body mass index, height and waist-to-hip ratio, as well as clinical classes of obesity, including up to 263,407 individuals of European ancestry, we identified 4 new loci (IGFBP4, H6PD, RSRC1 and PPP2R2A) influencing height detected in the distribution tails and 7 new loci (HNF4G, RPTOR, GNAT2, MRPS33P4, ADCY9, HS6ST3 and ZZZ3) for clinical classes of obesity. Further, we find a large overlap in genetic structure and the distribution of variants between traits based on extremes and the general population and little etiological heterogeneity between obesity subgroups.
  •  
3.
  • Eeg-Olofsson, Måns, 1967, et al. (author)
  • BCI-bone conduction implant.
  • 2013
  • In: The Fourth International Symposium on Bone Conduction Hearing – Craniofacial Osseointegration. Newcastle, UK.
  • Conference paper (other academic/artistic)
  •  
4.
  • Eeg-Olofsson, Måns, 1967, et al. (author)
  • Evaluation of bone tissue formation in a flat surface attachment of a Bone Conduction Implant - A pilot study in a sheep model
  • 2014
  • In: Audiology & Neurotology Extra. - : S. Karger AG. - 1664-5537. ; 4:3, s. 62-76
  • Journal article (peer-reviewed)abstract
    • The Bone Conduction Implant (BCI) is a new bone conduction hearing device implanted under intact skin. The transducer has a flat direct contact to the mastoid part of the temporal bone and no screws are used. The sound signal is transmitted from the external audio processor to the implant by means of magnetic induction. In this study, osseointegration of a flat passive BCI transducer dummy in sheep skulls was assessed using quantitative and qualitative histology as well as Cone Beam Computed Tomography (CBCT) and Computed Tomography (CT). The histology results were also related to the mechanical properties of the bone to implant interface. Eight months after the surgical implantation, histology sections of the bone close to the implant showed bone remodelling, compact bone and some degree of osseointegration. The histological findings corresponded well to the mechanical measurements indicating stiffer bone close to the implant, and unaffected skull vibration transmission. Neither CBCT nor CT had enough resolution to visualize the bone to implant interface in detail. In this study, using an animal model, it is shown that a flat implant in contact with bone, can be a feasible method for efficient vibration transmission to the skull bone.
  •  
5.
  •  
6.
  • Fredén Jansson, Karl-Johan, 1988, et al. (author)
  • Bone Conduction Stimulated VEMP Using the B250 Transducer
  • 2021
  • In: Medical Devices: Evidence and Research. - 1179-1470. ; 14, s. 225-237
  • Journal article (peer-reviewed)abstract
    • Objective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation. Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone. Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ. Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones.
  •  
7.
  • Fredén Jansson, Karl-Johan, 1988, et al. (author)
  • Electroacoustic evaluation of the bone conduction transducer B250 for vestibular and hearing diagnostics in comparison with Radioear B71 and B81
  • 2024
  • In: International Journal of Audiology. - 1499-2027 .- 1708-8186. ; In Press
  • Journal article (peer-reviewed)abstract
    • Objective: The objective is to evaluate the electroacoustic performance of the B250 transducer and to compare it with the two most widely used audiometric transducers B71 and B81. Design: The electroacoustic performance was evaluated in terms of sensitivity level, distortion, maximum hearing level and electrical impedance. Study sample: Six B250 prototype transducers were evaluated and compared with published data of B71 and B81 together with complementary measurements of maximum hearing level at 125 Hz and phase of electrical impedance. Differences in reference equivalent threshold vibratory force levels were estimated by comparing hearing threshold measurements of 60 healthy ears using B81 and B250. Results: B250 has approximately 27 dB higher sensitivity levels than both B71 and B81 at 250 Hz and can generate higher maximum hearing level at low frequencies: 11.8 to 35.8 dB (125–1000 Hz) higher than B71, and 1.4 to 18.6 dB (125–750 Hz) higher than B81. The maximum average difference in reference threshold force levels was 13.5 ± 8.7 dB higher for B250 at 250 Hz compared to B81. Conclusions: B250 can produce higher output force with less distortion than B71 and B81, especially at 125 and 250 Hz, which could possibly improve low frequency investigations of the audio-vestibular system.
  •  
8.
  • Fredén Jansson, Karl-Johan, 1988, et al. (author)
  • Electroacoustic evaluation of the bone conduction transducer B250 for vestibular and hearing diagnostics in comparison with Radioear B71 and B81
  • 2024
  • In: INTERNATIONAL JOURNAL OF AUDIOLOGY. - 1499-2027 .- 1708-8186.
  • Journal article (peer-reviewed)abstract
    • ObjectiveThe objective is to evaluate the electroacoustic performance of the B250 transducer and to compare it with the two most widely used audiometric transducers B71 and B81.DesignThe electroacoustic performance was evaluated in terms of sensitivity level, distortion, maximum hearing level and electrical impedance.Study sampleSix B250 prototype transducers were evaluated and compared with published data of B71 and B81 together with complementary measurements of maximum hearing level at 125 Hz and phase of electrical impedance. Differences in reference equivalent threshold vibratory force levels were estimated by comparing hearing threshold measurements of 60 healthy ears using B81 and B250.ResultsB250 has approximately 27 dB higher sensitivity levels than both B71 and B81 at 250 Hz and can generate higher maximum hearing level at low frequencies: 11.8 to 35.8 dB (125-1000 Hz) higher than B71, and 1.4 to 18.6 dB (125-750 Hz) higher than B81. The maximum average difference in reference threshold force levels was 13.5 +/- 8.7 dB higher for B250 at 250 Hz compared to B81.ConclusionsB250 can produce higher output force with less distortion than B71 and B81, especially at 125 and 250 Hz, which could possibly improve low frequency investigations of the audio-vestibular system.
  •  
9.
  • Fredén Jansson, Karl-Johan, 1988, et al. (author)
  • Magnetic resonance imaging investigation of the bone conduction implant - a pilot study at 1.5 Tesla.
  • 2015
  • In: Medical devices (Auckland, N.Z.). - 1179-1470. ; 8, s. 413-23
  • Journal article (peer-reviewed)abstract
    • The objective of this pilot study was to investigate if an active bone conduction implant (BCI) used in an ongoing clinical study withstands magnetic resonance imaging (MRI) of 1.5 Tesla. In particular, the MRI effects on maximum power output (MPO), total harmonic distortion (THD), and demagnetization were investigated. Implant activation and image artifacts were also evaluated.
  •  
10.
  • Fredén Jansson, Karl-Johan, 1988, et al. (author)
  • MRI Induced Torque and Demagnetization in Retention Magnets for a Bone Conduction Implant
  • 2014
  • In: IEEE Transactions on Biomedical Engineering. - : Institute of Electrical and Electronics Engineers (IEEE). - 0018-9294 .- 1558-2531. ; 61:6, s. 1887-1893
  • Journal article (peer-reviewed)abstract
    • Performing magnetic resonance imaging (MRI) examinations in patients who use implantable medical devices involve safety risks both for the patient and the implant. Hearing implants often use two permanent magnets, one implanted and one external, for the retention of the external transmitter coil to the implanted receiver coil to achieve an optimal signal transmission. The implanted magnet is subjected to both demagnetization and torque, magnetically induced by the MRI scanner. In this paper, demagnetization and a comparison between measured and simulated induced torque is studied for the retention magnet used in a bone conduction implant (BCI) system. The torque was measured and simulated in a uniform static magnetic field of 1.5 T. The magnetic field was generated by a dipole electromagnet and permanent magnets with two different types of coercive fields were tested. Demagnetization and maximum torque for the high coercive field magnets was 7.7% +/- 2.5% and 0.20 +/- 0.01 Nm, respectively and 71.4% +/- 19.1% and 0.18 +/- 0.01 Nm for the low coercive field magnets, respectively. The simulated maximum torque was 0.34 Nm, deviating from the measured torque in terms of amplitude, mainly related to an insufficient magnet model. The BCI implant with high coercive field magnets is believed to be magnetic resonance (MR) conditional up to 1.5 T if a compression band is used around the skull to fix the implant. This is not approved and requires further investigations, and if removal of the implant is needed, the surgical operation is expected to be simple.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 37
Type of publication
journal article (31)
conference paper (3)
other publication (2)
reports (1)
Type of content
peer-reviewed (31)
other academic/artistic (6)
Author/Editor
Reinfeldt, Sabine, 1 ... (28)
Khaw, Kay-Tee (3)
Lorentzon, Mattias, ... (3)
Salomaa, Veikko (3)
Jula, Antti (3)
Perola, Markus (3)
show more...
Soranzo, Nicole (3)
Campbell, Harry (3)
Rudan, Igor (3)
Ohlsson, Claes, 1965 (3)
Wareham, Nicholas J. (3)
Kuusisto, Johanna (3)
Laakso, Markku (3)
Amin, Najaf (3)
van Duijn, Cornelia ... (3)
Boehnke, Michael (3)
Ripatti, Samuli (3)
Tuomilehto, Jaakko (3)
Thorleifsson, Gudmar (3)
Thorsteinsdottir, Un ... (3)
Stefansson, Kari (3)
Gieger, Christian (3)
Peters, Annette (3)
Wichmann, H. Erich (3)
Barroso, Ines (3)
Spector, Timothy D (3)
Luan, Jian'an (3)
Wilson, James F. (3)
Eriksson, Johan G. (3)
Jansson, John-Olov, ... (3)
Zillikens, M. Carola (3)
Rivadeneira, Fernand ... (3)
Johnson, Toby (3)
Harris, Tamara B (3)
Homuth, Georg (3)
Launer, Lenore J (3)
Loos, Ruth J F (3)
Hofman, Albert (3)
Hayward, Caroline (3)
Gudnason, Vilmundur (3)
Polasek, Ozren (3)
Illig, Thomas (3)
Jansson, Per-Erik. (3)
Feitosa, Mary F. (3)
Estrada, Karol (3)
Grallert, Harald (3)
Schipf, Sabine (3)
Widen, Elisabeth (3)
Borecki, Ingrid B. (3)
O'Connell, Jeffrey R ... (3)
show less...
University
Chalmers University of Technology (28)
University of Gothenburg (21)
Karolinska Institutet (7)
Royal Institute of Technology (3)
Uppsala University (3)
Lund University (3)
show more...
Swedish University of Agricultural Sciences (3)
Umeå University (2)
Stockholm University (1)
Linköping University (1)
Malmö University (1)
show less...
Language
English (36)
Swedish (1)
Research subject (UKÄ/SCB)
Medical and Health Sciences (29)
Engineering and Technology (12)
Natural sciences (5)
Agricultural Sciences (3)
Social Sciences (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view