SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Jarenbäck Linnea) "

Sökning: WFRF:(Jarenbäck Linnea)

  • Resultat 1-10 av 15
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Backer, Vibeke, et al. (författare)
  • Clinical characteristics of the BREATHE cohort–a real-life study on patients with asthma and COPD
  • 2020
  • Ingår i: European clinical respiratory journal. - : Informa UK Limited. - 2001-8525. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The BREATHE study is a cross-sectional study of real-life patients with asthma and/or COPD in Denmark and Sweden aiming to increase the knowledge across severities and combinations of obstructive airway disease. Design: Patients with suspicion of asthma and/or COPD and healthy controls were invited to participate in the study and had a standard evaluation performed consisting of questionnaires, physical examination, FeNO and lung function, mannitol provocation test, allergy test, and collection of sputum and blood samples. A subgroup of patients and healthy controls had a bronchoscopy performed with a collection of airway samples. Results: The study population consisted of 1403 patients with obstructive airway disease (859 with asthma, 271 with COPD, 126 with concurrent asthma and COPD, 147 with other), and 89 healthy controls (smokers and non-smokers). Of patients with asthma, 54% had moderate-to-severe disease and 46% had mild disease. In patients with COPD, 82% had groups A and B, whereas 18% had groups C and D classified disease. Patients with asthma more frequently had childhood asthma, atopic dermatitis, and allergic rhinitis, compared to patients with COPD, asthma + COPD and Other, whereas FeNO levels were higher in patients with asthma and asthma + COPD compared to COPD and Other (18 ppb and 16 ppb vs 12.5 ppb and 14 ppb, p < 0.001). Patients with asthma, asthma + COPD and Other had higher sputum eosinophilia (1.5%, 1.5%, 1.2% vs 0.75%, respectively, p < 0.001) but lower sputum neutrophilia (39.3, 43.5%, 40.8% vs 66.8%, p < 0.001) compared to patients with COPD. Conclusions: The BREATHE study provides a unique database and biobank with clinical information and samples from 1403 real-life patients with asthma, COPD, and overlap representing different severities of the diseases. This research platform is highly relevant for disease phenotype- and biomarker studies aiming to describe a broad spectrum of obstructive airway diseases.
  •  
2.
  • Bajc, Marika, et al. (författare)
  • Grading obstructive lung disease using tomographic pulmonary scintigraphy in patients with chronic obstructive pulmonary disease (COPD) and long-term smokers.
  • 2015
  • Ingår i: Annals of Nuclear Medicine. - : Springer Science and Business Media LLC. - 1864-6433 .- 0914-7187. ; 29:1, s. 91-99
  • Tidskriftsartikel (refereegranskat)abstract
    • The severity of chronic obstructive lung disease (COPD) is defined by the degree of flow limitation measured as forced expiratory volume in 1 s, which mainly reflects impairment of large and intermediate airways. However, COPD is primarily a small airways disease. Therefore, better diagnostic tools are needed. Ventilation-Perfusion (V/P) SPECT is a sensitive method to detect obstructive lung changes but criteria for staging airway obstruction are missing.
  •  
3.
  • Eriksson, Göran, et al. (författare)
  • A new approach to assess COPD by identifying lung function break-points.
  • 2015
  • Ingår i: The International Journal of Chronic Obstructive Pulmonary Disease. - 1178-2005. ; 10, s. 2193-2202
  • Tidskriftsartikel (refereegranskat)abstract
    • COPD is a progressive disease, which can take different routes, leading to great heterogeneity. The aim of the post-hoc analysis reported here was to perform continuous analyses of advanced lung function measurements, using linear and nonlinear regressions.
  •  
4.
  • Eriksson, Göran, et al. (författare)
  • A new maximal bicycle test using a prediction algorithm developed from four large COPD studies
  • 2020
  • Ingår i: European clinical respiratory journal. - : Informa UK Limited. - 2001-8525. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Maximum exercise workload (WMAX) is today assessed as the first part of Cardiopulmonary Exercise testing. The WMAX test exposes patients with COPD, often having cardiovascular comorbidity, to risks. Our research project was initiated with the final aim to eliminate the WMAX test and replace this test with a predicted value of WMAX, based on a prediction algorithm of WMAX derived from multicentre studies. Methods: Baseline data (WMAX, demography, lung function parameters) from 850 COPD patients from four multicentre studies were collected and standardized. A prediction algorithm was prepared using Random Forest modelling. Predicted values of WMAX were used in a new WMAX test, which used a linear increase in order to reach the predicted WMAX within 8 min. The new WMAX test was compared with the standard stepwise WMAX test in a pilot study including 15 patients with mild/moderate COPD. Results: The best prediction algorithm of WMAX included age, sex, height, weight, and six lung function parameters. FEV1 and DLCO were the most important predictors. The new WMAX test had a better correlation (R2 = 0.84) between predicted and measured WMAX than the standard WMAX test (R2 = 0.66), with slopes of 0.50 and 0.46, respectively. The results from the new WMAX test and the standard WMAX test correlated well. Conclusion: A prediction algorithm based on data from four large multicentre studies was used in a new WMAX test. The prediction algorithm provided reliable values of predicted WMAX. In comparison with the standard WMAX test, the new WMAX test provided similar overall results.
  •  
5.
  • Jarenbäck, Linnea, et al. (författare)
  • Acinar ventilation heterogeneity in COPD relates to diffusion capacity, resistance and reactance.
  • 2016
  • Ingår i: Respiratory Medicine. - : Elsevier BV. - 1532-3064 .- 0954-6111. ; 110:nov 11, s. 28-33
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to investigate heterogenic ventilation in the acinar (Sacin) and conductive (Scond) airways of patients with varying chronic obstructive pulmonary disease (COPD) severity and how these relates to advanced lung function parameters, primarily measured by impulse oscillometry (IOS). A secondary aim was to investigate the effects of a short acting beta2-agonist and a muscarinic antagonist on the heterogenic ventilation. Eleven never smoking controls, 12 smoking controls, and 57 COPD patients (7 GOLD 1, 25 GOLD 2, 14 GOLD 3 and 11 GOLD 4) performed flow-volume spirometry, IOS, body plethysmography, single breath carbon monoxide diffusion, and N2-multiple breath washout. Six smoking controls and 13 of the COPD patients also performed double reversibility test by using salbutamol and its combination with ipratropium. Sacin was significantly higher in GOLD 2-4 compared to never smoking controls and smoking controls, but showed similar levels in GOLD 3 and 4. A factor analysis identified 4 components consisting of; 1) IOS parameters, 2) volume parameters, 3) diffusion parameters, Sacin and some IOS parameters and 4) Scond with central obstruction/air trapping. Salbutamol and its combination with ipratropium had no effect on Sacin and Scond. Increased Sacin in COPD was strongly related to diffusion capacity and lung volumes, but also weakly to resistance and reactance, showing a link between ventilation heterogeneity in the acinar airways and parameters measured by IOS.
  •  
6.
  • Jarenbäck, Linnea, et al. (författare)
  • Bronchodilator response of advanced lung function parameters depending on COPD severity
  • 2016
  • Ingår i: International Journal of COPD. - 1176-9106. ; 11:1, s. 2939-2950
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: COPD is defined as partly irreversible airflow obstruction. The response pattern of bronchodilators has not been followed in advanced lung function parameters. Purpose: The aim of this study was to investigate bronchodilator response pattern in advanced lung function parameters in a continuous fashion along forced expiratory volume in 1 second (FEV1) percent predicted (%p) in COPD patients and controls. Patients and methods: Eighty-one smokers/ex-smokers (41 controls and 40 COPD) performed spirometry, body plethysmography, impulse oscillometry and single-breath helium dilution carbon monoxide diffusion at baseline, after salbutamol inhalation and then after an additional inhalation of ipratropium. Results: Most pulmonary function parameters showed a linear increase in response to decreased FEV1%p. The subjects were divided into groups of FEV1%p<65 and >65, and the findings from continuous analysis were verified. The exceptions to this linear response were inspiratory capacity (IC), forced vital capacity (FVC), FEV1/FVC and expiratory resistance (Rex), which showed a segmented response relationship to FEV1%p. IC and FVC, with break points (BP) of 57 and 58 FEV1%p respectively, showed no response above, but an incresed slope below the BP. In addition, in patients with FEV1%p<65 and >65, response of FEV1%p did not correlate to response of volume parameters. Conclusion: Response of several advanced lung function parameters differs depending on patients’ baseline FEV1%p, and specifically response of volume parameters is most pronounced in COPD patients with FEV1%p<65. Volume and resistance responses do not follow the flow response measured with FEV1 and may thus be used as a complement to FEV1 reversibility to identify flow, volume and resistance responders.
  •  
7.
  •  
8.
  • Jarenbäck, Linnea, et al. (författare)
  • Flow-Volume Parameters in COPD Related to Extended Measurements of Lung Volume, Diffusion, and Resistance.
  • 2013
  • Ingår i: Pulmonary Medicine. - : Hindawi Limited. - 2090-1844 .- 2090-1836. ; 2013
  • Tidskriftsartikel (refereegranskat)abstract
    • Classification of COPD into different GOLD stages is based on forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) but has shown to be of limited value. The aim of the study was to relate spirometry values to more advanced measures of lung function in COPD patients compared to healthy smokers. The lung function of 65 COPD patients and 34 healthy smokers was investigated using flow-volume spirometry, body plethysmography, single breath helium dilution with CO-diffusion, and impulse oscillometry. All lung function parameters, measured by body plethysmography, CO-diffusion, and impulse oscillometry, were increasingly affected through increasing GOLD stage but did not correlate with FEV1 within any GOLD stage. In contrast, they correlated fairly well with FVC%p, FEV1/FVC, and inspiratory capacity. Residual volume (RV) measured by body plethysmography increased through GOLD stages, while RV measured by helium dilution decreased. The difference between these RV provided valuable additional information and correlated with most other lung function parameters measured by body plethysmography and CO-diffusion. Airway resistance measured by body plethysmography and impulse oscillometry correlated within COPD stages. Different lung function parameters are of importance in COPD, and a thorough patient characterization is important to understand the disease.
  •  
9.
  • Jarenbäck, Linnea, et al. (författare)
  • Single-nucleotide polymorphisms in the sulfatase-modifying factor 1 gene are associated with lung function and COPD
  • 2022
  • Ingår i: ERJ open research. - : European Respiratory Society (ERS). - 2312-0541. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • Single nucleotide polymorphisms (SNPs) in various genes have been shown to associate with COPD, suggesting a role in disease pathogenesis. Sulfatase modifying factor (SUMF1) is a key modifier in connective tissue remodelling, and we have shown previously that several SNPs in SUMF1 are associated with COPD. The aim of this study was to investigate the association between SUMF1 SNPs and advanced lung function characteristics. Never-, former and current smokers with (n=154) or without (n=405) COPD were genotyped for 21 SNPs in SUMF1 and underwent spirometry, body plethysmography, diffusing capacity of the lung for carbon monoxide ( D LCO) measurement and impulse oscillometry. Four SNPs (rs793391, rs12634248, rs2819590 and rs304092) showed a significantly decreased odds ratio of having COPD when heterozygous for the variance allele, together with a lower forced expiratory volume in 1 s (FEV 1) and FEV 1/forced vital capacity (FVC) ratio and an impaired peripheral resistance and reactance. Moreover, individuals homozygous for the variance allele of rs3864051 exhibited a strong association to COPD, a lower FEV 1/FVC, FEV 1 and D LCO, and an impaired peripheral resistance and reactance. Other SNPs (rs4685744, rs2819562, rs2819561 and rs11915920) were instead associated with impaired lung volumes and exhibited a lower FVC, total lung capacity and alveolar volume, in individuals having the variance allele. Several SNPs in the SUMF1 gene are shown to be associated with COPD and impaired lung function. These genetic variants of SUMF1 may cause a deficient sulfation balance in the extracellular matrix of the lung tissue, thereby contributing to the development of COPD.
  •  
10.
  • Jarenbäck, Linnea, et al. (författare)
  • The Efficiency Index (EFFi), based on volumetric capnography, may allow for simple diagnosis and grading of COPD
  • 2018
  • Ingår i: International Journal of COPD. - 1176-9106. ; 13, s. 2033-2039
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Spirometry, the main tool for diagnosis and follow-up of COPD, incompletely describes the disease. Based on volumetric capnography (VCap), an index was developed for the diagnosis and grading of COPD, aimed as a complement or alternative to spirometry. Methods: Nine non-smokers, 10 smokers/former smokers without COPD and 54 smokers/ former smokers with COPD were included in the study. Multiple breath washout of N2 and VCap were studied with Exhalyzer D during tidal breathing. VCap was based on signals for flow rate and CO2 and was recorded during one breath preceding N2 washout. Efficiency Index (EFFi) is the quotient between exhaled CO2 volume and the hypothetical CO2 volume exhaled from a completely homogeneous lung over a volume interval equal to 15% of predicted total lung capacity. Results: EFFi increased with increased Global initiative for chronic Obstructive Lung Disease (GOLD) stage and the majority of subjects in GOLD 2 and all subjects in GOLD 3 and 4 could be diagnosed as having COPD using the lower 95% confidence interval of the healthy group. EFFi also correlated with N2 washout (r=-0.73; p,0.001), forced expiratory volume in 1 second (r=0.70; p,0.001) and diffusion capacity for carbon oxide (r=0.69; p,0.001). Conclusion: EFFi measures efficiency of tidal CO2 elimination that is limited by inhomogeneity of peripheral lung function. EFFi allows diagnosis and grading of COPD and, together with FEV1, may explain limitation of physical performance. EFFi offers a simple, effortless and cost-effective complement to spirometry and might serve as an alternative in certain situations.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 15

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy