SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kühn Thorsten) "

Sökning: WFRF:(Kühn Thorsten)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Abelev, Betty, et al. (författare)
  • Long-range angular correlations on the near and away side in p-Pb collisions at root S-NN=5.02 TeV
  • 2013
  • Ingår i: Physics Letters. Section B: Nuclear, Elementary Particle and High-Energy Physics. - : Elsevier BV. - 0370-2693. ; 719:1-3, s. 29-41
  • Tidskriftsartikel (refereegranskat)abstract
    • Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5 < P-T,P-assoc < P-T,P-trig < 4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and p(T) bins, and the widths show no significant evolution with event multiplicity or p(T). These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge. (c) 2013 CERN. Published by Elsevier B.V. All rights reserved.
  •  
3.
  • Alkner, Sara, et al. (författare)
  • Quality assessment of radiotherapy in the prospective randomized SENOMAC trial
  • 2024
  • Ingår i: Radiotherapy and Oncology. - 0167-8140 .- 1879-0887. ; 197
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Recommendations for regional radiotherapy (RT) of sentinel lymph node (SLN)-positive breast cancer are debated. We here report a RT quality assessment of the SENOMAC trial.Materials and Methods: The SENOMAC trial randomized clinically node-negative breast cancer patients with 1–2 SLN macrometastases to completion axillary lymph node dissection (cALND) or SLN biopsy only between 2015–2021. Adjuvant RT followed national guidelines. RT plans for patients included in Sweden and Denmark until June 2019 were collected (N = 1176) and compared to case report forms (CRF). Dose to level I (N = 270) and the humeral head (N = 321) was analyzed in detail.Results: CRF-data and RT plans agreed in 99.3 % (breast/chest wall) and in 96.6 % of patients (regional RT). Congruence for whether level I was an intended RT target was lower (78 %). In accordance with Danish national guidelines, level I was more often an intended target in the SLN biopsy only arm (N = 334/611, 55 %,) than in the cALND arm (N = 174/565, 31 %,). When an intended target, level I received prescribed dose to 100 % (IQR 98–100 %) of the volume. However, even when not an intended target, full dose was delivered to > 80 % of level I (IQR 75–90 %). The intentional inclusion of level I in the target volume more than doubled the dose received by ≥ 50 % of the humeral head.Conclusion: Congruence between CRF data and RT plans was excellent. Level I received a high dose coverage even when not intentionally included in the target. Including level I in target significantly increased dose to the humeral head.
  •  
4.
  • Banys-Paluchowski, Maggie, et al. (författare)
  • Localization Techniques for Non-Palpable Breast Lesions : Current Status, Knowledge Gaps, and Rationale for the MELODY Study (EUBREAST-4/iBRA-NET, NCT 05559411)
  • 2023
  • Ingår i: Cancers. - : MDPI. - 2072-6694. ; 15:4
  • Forskningsöversikt (refereegranskat)abstract
    • Background: Surgical excision of a non-palpable breast lesion requires a localization step. Among available techniques, wire-guided localization (WGL) is most commonly used. Other techniques (radioactive, magnetic, radar or radiofrequency-based, and intraoperative ultrasound) have been developed in the last two decades with the aim of improving outcomes and logistics.Methods: We performed a systematic review on localization techniques for non-palpable breast cancer.Results: For most techniques, oncological outcomes such as lesion identification and clear margin rate seem either comparable with or better than for WGL, but evidence is limited to small cohort studies for some of the devices. Intraoperative ultrasound is associated with significantly higher negative margin rates in meta-analyses of randomized clinical trials (RCTs). Radioactive techniques were studied in several RCTs and are non-inferior to WGL. Smaller studies show higher patient preference towards wire-free localization, but little is known about surgeons’ and radiologists’ attitudes towards these techniques.Conclusions: Large studies with an additional focus on patient, surgeon, and radiologist preference are necessary. This review aims to present the rationale for the MELODY (NCT05559411) study and to enable standardization of outcome measures for future studies.Simple summaryMost breast cancers are small and can be treated using breast-conserving surgery. Since these tumors are non-palpable, they require a localization step that helps the surgeon to decide which tissue needs to be removed. The oldest localization technique is a guidewire placed into the tumor before surgery, usually using ultrasound or mammography. Afterwards, the surgeon removes the tissue around the wire tip. However, this technique has several disadvantages: It can cause the patient discomfort, requires a radiologist or another professional specialized in breast diagnostics to perform the procedure shortly before surgery, and 15–20% of patients need a second surgery to completely remove the tumor. Therefore, new techniques have been developed but most of them have not yet been examined in large, prospective, multicenter studies. In this review, we discuss all available techniques and present the MELODY study that will investigate their safety, with a focus on patient, surgeon, and radiologist preference.
  •  
5.
  • Franke, A., et al. (författare)
  • Operationalizing Ocean Health : Toward Integrated Research on Ocean Health and Recovery to Achieve Ocean Sustainability
  • 2020
  • Ingår i: One Earth. - : Elsevier BV. - 2590-3330 .- 2590-3322. ; 2:6, s. 557-565
  • Tidskriftsartikel (refereegranskat)abstract
    • Protecting the ocean has become a major goal of international policy as human activities increasingly endanger the integrity of the ocean ecosystem, often summarized as “ocean health.” By and large, efforts to protect the ocean have failed because, among other things, (1) the underlying socio-ecological pathways have not been properly considered, and (2) the concept of ocean health has been ill defined. Collectively, this prevents an adequate societal response as to how ocean ecosystems and their vital functions for human societies can be protected and restored. We review the confusion surrounding the term “ocean health” and suggest an operational ocean-health framework in line with the concept of strong sustainability. Given the accelerating degeneration of marine ecosystems, the restoration of regional ocean health will be of increasing importance. Our advocated transdisciplinary and multi-actor framework can help to advance the implementation of more active measures to restore ocean health and safeguard human health and well-being.
  •  
6.
  • Hersi, Abdi-Fatah, 1989- (författare)
  • Superparamagnetic iron oxide nanoparticles, a novel tracer in breast cancer surgery
  • 2021
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The most common surgical choice of treatment in breast cancer is breast-conserving surgery (BCS) together with sentinel lymph node biopsy (SNB). Around 10% of breast cancer diagnosis are ductal carcinoma in situ (DCIS). Superparamagnetic iron oxide nanoparticles (SPIO) are a novel tracer for sentinel lymph node (SN) detection. The aim of this thesis was to investigate the unique applications and functionality of a magnetic approach in breast cancer surgery.Paper I was a two-centre pilot study of 32 patients with non-palpable breast cancer who were scheduled for BCS together with SNB. They received SPIO for SNB and a magnetic seed (Magseed®) for localization of the breast tumour. All 32 patients underwent microscopically radical resection and SNB was successfully performed in all included patients.Paper II was a multicentre prospective single-cohort study. It was a pre-planned interim analysis of 189 patients with “high-risk” DCIS who received SPIO at primary surgery but without performing SNB. If an invasive breast cancer was shown by the final histopathology report, the patient was scheduled for second surgery to undergo SNB. Because SPIO has a much longer half-life than the radioisotope, the magnetic signal at the second surgery was sufficient for detecting SNs; in fact, in patients with DCIS, it reduced from around 50% to 22%. Paper III was a multicentre prospective trial. Two consecutive cohorts of patients with breast cancer scheduled for SNB (n = 328) were included. Lower doses of a refined SPIO suspension were tested in different time frames and injection sites. Analyses were performed as a one-step individual patient-level meta-analysis using patient-level data from a similar previous cohort (n = 206) as a third reference group. In 534 patients, the SPIO SN detection rates were comparable (97.5% vs. 100% vs. 97.6%, p = 0.11) and were noninferior to the dual technique. Paper IV was a multicentre randomized pilot trial aimed to compare tumour localization in nonpalpable breast cancers using either Magseed® or guidewire in patients scheduled for BCS + SNB. All patients received SPIO for the SNB preoperatively. Patients who were randomized to the magnetic seed cohort received their Magseed® at the same time as the SPIO injection preoperatively while the guidewire placement was performed on the same day as surgery. In 207 patients, there were no significant differences in reoperation rate (3% in the magnetic seed cohort vs 7% in the guidewire cohort, p = 0.35). 
  •  
7.
  • Kaidar-Person, Orit, et al. (författare)
  • The Lucerne Toolbox 2 to optimise axillary management for early breast cancer : a multidisciplinary expert consensus
  • 2023
  • Ingår i: EClinicalMedicine. - 2589-5370. ; 61
  • Forskningsöversikt (refereegranskat)abstract
    • Clinical axillary lymph node management in early breast cancer has evolved from being merely an aspect of surgical management and now includes the entire multidisciplinary team. The second edition of the “Lucerne Toolbox”, a multidisciplinary consortium of European cancer societies and patient representatives, addresses the challenges of clinical axillary lymph node management, from diagnosis to local therapy of the axilla. Five working packages were developed, following the patients’ journey and addressing specific clinical scenarios. Panellists voted on 72 statements, reaching consensus (agreement of 75% or more) in 52.8%, majority (51%–74% agreement) in 43.1%, and no decision in 4.2%. Based on the votes, targeted imaging and standardized pathology of lymph nodes should be a prerequisite to planning local and systemic therapy, axillary lymph node dissection can be replaced by sentinel lymph node biopsy ( ± targeted approaches) in a majority of scenarios; and positive patient outcomes should be driven by both low recurrence risks and low rates of lymphoedema.
  •  
8.
  • Pantiora, Eirini, et al. (författare)
  • Evolution and refinement of magnetically guided sentinel lymph node detection in breast cancer : meta-analysis
  • 2023
  • Ingår i: British Journal of Surgery. - : Oxford University Press. - 0007-1323 .- 1365-2168. ; 110:4, s. 410-419
  • Forskningsöversikt (refereegranskat)abstract
    • BACKGROUND: Superparamagnetic iron oxide nanoparticles (SPIO) have been used as a tracer for sentinel lymph node (SLN) localization in breast cancer, demonstrating comparable performance to the combination of radioisotope (RI) and blue dye (BD).METHODS: A systematic literature search and meta-analysis with subgroup and meta-regression analysis were undertaken to update the available evidence, assess technique evolution, and define knowledge gaps. Recommendations were made using the GRADE approach.RESULTS: In 20 comparative studies, the detection rate was 97.5 per cent for SPIO and 96.5 per cent for RI ± BD (risk ratio 1.006, 95 per cent c.i. 0.992 to 1.019; P = 0.376, high-certainty evidence). Neoadjuvant therapy, injection site, injection volume or nodal metastasis burden did not affect the detection rate, but injection over 24 h before surgery increased the detection rate on meta-regression. Concordance was 99.0 per cent and reverse concordance 97.1 per cent (rate difference 0.003, 95 per cent c.i. -0.009 to 0.015; P = 0.656, high-certainty evidence). Use of SPIO led to retrieval of slightly more SLNs (pooled mean 1.96 versus 1.89) with a higher nodal detection rate (94.1 versus 83.5 per cent; RR 1.098, 1.058 to 1.140; P < 0.001; low-certainty evidence). In meta-regression, injection over 24 h before surgery increased the SPIO nodal yield over that of RI ± BD. The skin-staining rate was 30.8 per cent (very low-certainty evidence), and possibly prevented with use of smaller doses and peritumoral injection.CONCLUSION: The performance of SPIO is comparable to that of RI ± BD. Preoperative injection increases the detection rate and nodal yield, without affecting concordance. Whether skin staining and MRI artefacts are reduced by lower dose and peritumoral injection needs to be investigated.
  •  
9.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9
Typ av publikation
tidskriftsartikel (5)
forskningsöversikt (3)
doktorsavhandling (1)
Typ av innehåll
refereegranskat (8)
övrigt vetenskapligt/konstnärligt (1)
Författare/redaktör
Zhang, Yan (1)
Oskarsson, Anders (1)
Stenlund, Evert (1)
Korhonen, Laura (1)
Lindholm, Dan (1)
Rydén, Lisa (1)
visa fler...
Blanco, F. (1)
Christiansen, Peter (1)
Dobrin, Alexandru (1)
Majumdar, A. K. Dutt ... (1)
Gros, Philippe (1)
Kurepin, A. (1)
Kurepin, A. B. (1)
Poortmans, Philip (1)
Wieslander, Elinore (1)
Vertessy, Beata G. (1)
Ljunggren, Martin (1)
Malinina, Ludmila (1)
Milosevic, Jovan (1)
Ortiz Velasquez, Ant ... (1)
Richert, Tuva (1)
Sogaard, Carsten (1)
Kowalski, Marek (1)
Peskov, Vladimir (1)
Wang, Mei (1)
Wang, Xin (1)
Liu, Yang (1)
Kumar, Rakesh (1)
Abelev, Betty (1)
Adam, Jaroslav (1)
Adamova, Dagmar (1)
Adare, Andrew Marsha ... (1)
Aggarwal, Madan (1)
Rinella, Gianluca Ag ... (1)
Agnello, Michelangel ... (1)
Agocs, Andras Gabor (1)
Agostinelli, Andrea (1)
Ahammed, Zubayer (1)
Ahmad, Nazeer (1)
Ahmad, Arshad (1)
Ahn, Sul-Ah (1)
Ahn, Sang Un (1)
Ajaz, Muhammad (1)
Akindinov, Alexander (1)
Aleksandrov, Dmitry (1)
Alessandro, Bruno (1)
Alici, Andrea (1)
Alkin, Anton (1)
Almaraz Avina, Erick ... (1)
Alme, Johan (1)
visa färre...
Lärosäte
Uppsala universitet (3)
Lunds universitet (3)
Karolinska Institutet (3)
Umeå universitet (2)
Stockholms universitet (2)
Örebro universitet (1)
visa fler...
Linköpings universitet (1)
Naturhistoriska riksmuseet (1)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (9)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (6)
Naturvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy