SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Kelley DG) "

Sökning: WFRF:(Kelley DG)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Adcox, K, et al. (författare)
  • PHENIX detector overview
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 469-479
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX detector is designed to perform a broad study of A-A, p-A, and p-p collisions to investigate nuclear matter under extreme conditions. A wide variety of probes, sensitive to all timescales, are used to study systematic variations with species and energy as well as to measure the spin structure of the nucleon. Designing for the needs of the heavy-ion and polarized-proton programs has produced a detector with unparalleled capabilities. PHENIX measures electron and muon pairs, photons, and hadrons with excellent energy and momentum resolution. The detector consists of a large number of subsystems that are discussed in other papers in this volume. The overall design parameters of the detector are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Adcox, K, et al. (författare)
  • PHENIX central arm tracking detectors
  • 2003
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - 0167-5087. ; 499:2-3, s. 489-507
  • Tidskriftsartikel (refereegranskat)abstract
    • The PHENIX tracking system consists of Drift Chambers (DC), Pad Chambers (PC) and the Time Expansion Chamber (TEC). PC1/DC and PC2/TEC/PC3 form the inner and outer tracking units, respectively. These units link the track segments that transverse the RICH and extend to the EMCal. The DC measures charged particle trajectories in the r-phi direction to determine P-T of the particles and the invariant mass of particle pairs. The PCs perform 3D spatial point measurements for pattern recognition and longitudinal momentum reconstruction and provide spatial resolution of a few mm in both r-phi and z. The TEC tracks particles passing through the region between the RICH and the EMCal. The design and operational parameters of the detectors are presented and running experience during the first year of data taking with PHENIX is discussed. The observed spatial and momentum resolution is given which imposes a limitation on the identification and characterization of charged particles in various momentum ranges. (C) 2002 Published by Elsevier Science B.V.
  •  
3.
  •  
4.
  • Evers, AWM, et al. (författare)
  • What Should Clinicians Tell Patients about Placebo and Nocebo Effects? Practical Considerations Based on Expert Consensus
  • 2020
  • Ingår i: Psychotherapy and psychosomatics. - : S. Karger AG. - 1423-0348 .- 0033-3190. ; 90:1, s. 49-56
  • Tidskriftsartikel (refereegranskat)abstract
    • <b><i>Introduction:</i></b> Clinical and laboratory studies demonstrate that placebo and nocebo effects influence various symptoms and conditions after the administration of both inert and active treatments. <b><i>Objective:</i></b> There is an increasing need for up-to-date recommendations on how to inform patients about placebo and nocebo effects in clinical practice and train clinicians how to disclose this information. <b><i>Methods:</i></b> Based on previous clinical recommendations concerning placebo and nocebo effects, a 3-step, invitation-only Delphi study was conducted among an interdisciplinary group of internationally recognized experts. The study consisted of open- and closed-ended survey questions followed by a final expert meeting. The surveys were subdivided into 3 parts: (1) informing patients about placebo effects, (2) informing patients about nocebo effects, and (3) training clinicians how to communicate this information to the patients. <b><i>Results:</i></b> There was consensus that communicating general information about placebo and nocebo effects to patients (e.g., explaining their role in treatment) could be beneficial, but that such information needs to be adjusted to match the specific clinical context (e.g., condition and treatment). Experts also agreed that training clinicians to communicate about placebo and nocebo effects should be a regular and integrated part of medical education that makes use of multiple formats, including face-to-face and online modalities. <b><i>Conclusions:</i></b> The current 3-step Delphi study provides consensus-based recommendations and practical considerations for disclosures about placebo and nocebo effects in clinical practice. Future research is needed on how to optimally tailor information to specific clinical conditions and patients’ needs, and on developing standardized disclosure training modules for clinicians.
  •  
5.
  • Mahadeva, R, et al. (författare)
  • Polymers of Z alpha(1)-antitrypsin co-localize with neutrophils in emphysematous alveoli and are chemotactic in vivo
  • 2005
  • Ingår i: American Journal of Pathology. - 1525-2191. ; 166:2, s. 377-386
  • Tidskriftsartikel (refereegranskat)abstract
    • The molecular mechanisms that cause emphysema are complex but most theories suggest that an excess of proteinases is a crucial requirement. This paradigm is exemplified by severe deficiency of the key antielastase within the lung: alpha(1)-antitrypsin. The Z mutant of alpha(1)-antitrypsin has a point mutation Glu342Lys in the hinge region of the molecule that renders it prone to intermolecular linkage and loop-sheet polymerization. Polymers of Z alpha(1)-antitrypsin aggregate within the liver leading to juvenile liver cirrhosis and the resultant plasma deficiency predisposes to premature emphysema. We show here that polymeric alpha(1)-antitrypsin co-localizes with neutrophils in the alveoli of individuals with Z alpha(1)-antitrypsin-related emphysema. The significance of this finding is underscored by the excess of neutrophils in these individuals and the demonstration that polymers cause an influx of neutrophils when instilled into murine lungs. Polymers exert their effect directly on neutrophils rather than via inflammatory cytokines. These data provide an explanation for the accelerated tissue destruction that is characteristic of Z alpha(1)-antitrypsin-related emphysema. The transition of native Z alpha(1)-antitrypsin to polymers inactivates its anti-proteinase function, and also converts it to a proinflammatory stimulus. These findings may also explain the progression of emphysema in some individual despite alpha(1)-antitrypsin replacement therapy.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy