SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Khush Kiran K) "

Sökning: WFRF:(Khush Kiran K)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahn, Jung-Min, et al. (författare)
  • Prognostic value of comprehensive intracoronary physiology assessment early after heart transplantation.
  • 2021
  • Ingår i: European heart journal. - : Oxford University Press (OUP). - 1522-9645 .- 0195-668X. ; 42:48, s. 4918-4929
  • Tidskriftsartikel (refereegranskat)abstract
    • We evaluated the long-term prognostic value of invasively assessing coronary physiology after heart transplantation in a large multicentre registry.Comprehensive intracoronary physiology assessment measuring fractional flow reserve (FFR), the index of microcirculatory resistance (IMR), and coronary flow reserve (CFR) was performed in 254 patients at baseline (a median of 7.2weeks) and in 240 patients at 1year after transplantation (199 patients had both baseline and 1-year measurement). Patients were classified into those with normal physiology, reduced FFR (FFR≤0.80), and microvascular dysfunction (either IMR≥25 or CFR≤2.0 with FFR>0.80). The primary outcome was the composite of death or re-transplantation at 10years. At baseline, 5.5% had reduced FFR; 36.6% had microvascular dysfunction. Baseline reduced FFR [adjusted hazard ratio (aHR) 2.33, 95% confidence interval (CI) 0.88-6.15; P=0.088] and microvascular dysfunction (aHR 0.88, 95% CI 0.44-1.79; P=0.73) were not predictors of death and re-transplantation at 10years. At 1year, 5.0% had reduced FFR; 23.8% had microvascular dysfunction. One-year reduced FFR (aHR 2.98, 95% CI 1.13-7.87; P=0.028) and microvascular dysfunction (aHR 2.33, 95% CI 1.19-4.59; P=0.015) were associated with significantly increased risk of death or re-transplantation at 10years. Invasive measures of coronary physiology improved the prognostic performance of clinical variables (χ2 improvement: 7.41, P=0.006). However, intravascular ultrasound-derived changes in maximal intimal thickness were not predictive of outcomes.Abnormal coronary physiology 1year after heart transplantation was common and was a significant predictor of death or re-transplantation at 10years.
  •  
2.
  •  
3.
  • Miller, Robert J.H., et al. (författare)
  • Donor and Recipient Size Matching in Heart Transplantation With Predicted Heart and Lean Body Mass
  • 2022
  • Ingår i: Seminars in Thoracic and Cardiovascular Surgery. - : Elsevier. - 1043-0679 .- 1532-9488. ; 34:1, s. 158-167
  • Tidskriftsartikel (refereegranskat)abstract
    • Donor and recipient size matching during heart transplant can be assessed using weight or predicted heart mass (PHM) ratios. We developed sex-specific allomteric equations for PHM and predicted lean body mass (PLBM) using the United Kingdom Biobank (UKB) and evaluated their predictive value in the United Network of Organ Sharing database. Donor and recipient size matching was based on weight, PHM and PLBM ratios. PHM was calculated using the Multiethnic Study of Atherosclerosis and UKB equations. PLBM was calculated using the UKB and National Health and Nutrition Examination Survey equations. Relative prognostic utility was compared using multivariable Cox analysis, adjusted for predictors of 1-year survival in the Scientific Registry of Transplant Recipients model. Of 53,648 adult patients in the United Network of Organ Sharing database between 1996 and 2016, 6528 (12.2%) died within the first year. In multivariable analysis, undersized matches by any metric were associated with increased 1-year mortality (all P < 0.01). Oversized matches were at increased risk using PHM or PLBM (all P < 0.01), but not weight ratio. There were significant differences in classification of size matching by weight or PHM in sex-mismatched donor-recipient pairs. A significant interaction was observed between pulmonary hypertension and donor undersizing (hazard ratio 1.15, P = 0.026) suggesting increased risk of undersizing in pulmonary hypertension. Donor and recipient size matching with simplified PHM and PLBM offered an advantage over total body weight and may be more important for sex-mismatched donor-recipient pairs. Donor undersizing is associated with worse outcomes in patients with pulmonary hypertension.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy